The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Single molecule enzyme-linked immunosorbent assays: Theoretical considerations
Open accessAbstract
We have developed a highly sensitive immunoassay—called digital ELISA—that is based on the detection of single enzyme-linked immunocomplexes on beads that are sealed in arrays of femtoliter wells. Digital ELISA was designed to be highly efficient in the capturing of target proteins, labeling of these proteins, and their detection in single molecule arrays (SiMoA); in essence, the goal of the assay is to “capture every molecule, detect every molecule”. Here we provide the theoretical basis for the design of this assay derived from simple equations based on bimolecular interactions. Using these equations and knowledge of the concentrations of reagents, the times of interactions, and the on- and off-rates of the molecular interactions for each step of the assay, it is possible to predict the number of immunocomplexes that are formed and detected by SiMoA. The unique ability of SiMoA to count single immunocomplexes and determine an average number of enzymes per bead (AEB), makes it possible to directly compare the number of molecules detected experimentally to those predicted by theory. These predictions compare favorably to experimental data generated for a digital ELISA for prostate specific antigen (PSA). The digital ELISA process is efficient across a range of antibody affinities (KD ~ 10−11–10−9 M), and antibodies with high on-rates (kon > 105 M−1 s−1) are predicted to perform best. The high efficiency of digital ELISA and sensitivity of SiMoA to enzyme label also makes it possible to reduce the concentration of labeling reagent, reduce backgrounds, and increasing the specificity of the approach. Strategies for dealing with the dissociation of antibody complexes over time that can affect the signals in an assay are also described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cerebrospinal fluid biomarker signature in Alzheimer's disease neuroimaging initiative subjects
Shaw, L. M., Vanderstichele, H., Knapik‐Czajka, M., Clark, C. M., Aisen, P. S., Petersen, R. C., Blennow, K., Soares, H., Simon, A., Lewczuk, P., et al. (2009) · Annals of Neurology · doi:10.1002/ana.21610 · Cited by 2,065
Cited by
Wilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., et al. (2016) · SLAS Technology · doi:10.1177/2211068215589580 · Cited by 470
Self-citationSingle-Exosome-Counting Immunoassays for Cancer Diagnostics
Liu, C., Xu, X., Li, B., Situ, B., Pan, W., Hu, Y., An, T., Yao, S., & Zheng, L. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b01184 · Cited by 406
Yang, S.-M., Lv, S., Zhang, W., & Cui, Y. (2022) · Sensors · doi:10.3390/s22041620 · Cited by 299
Nonspecific Binding—Fundamental Concepts and Consequences for Biosensing Applications
Frutiger, A., Tanno, A., Hwu, S., Tiefenauer, R. F., Vörös, J., & Nakatsuka, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00044 · Cited by 278
Prospects for point-of-care pathogen diagnostics using surface-enhanced Raman scattering (SERS)
Granger, J. H., Schlotter, N. E., Crawford, A. C., & Porter, M. D. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00828j · Cited by 269
Metadata
- Authors
- Chang, L., Rissin, D. M., Fournier, D. R., Piech, T., Patel, P. P., Wilson, D. H., & Duffy, D. C.
- Venue
- Journal of Immunological Methods
- Publisher
- Elsevier BV
- Published
- 2012-04
- Volume
- 378
- Issue
- 1-2
- Pages
- 102-115
- ISSN
- 0022-1759 (ISSN-L)
- OpenAlex
- W1993116067
- Cited by
- 185
- References
- 1
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single molecule enzyme-linked immunosorbent assays: Theoretical considerations. https://app.cochat.ai/papers/10.1016/j.jim.2012.02.011
- The paper
- Chang, L., Rissin, D. M., Fournier, D. R., Piech, T., Patel, P. P., Wilson, D. H., & Duffy, D. C. (2012). Single molecule enzyme-linked immunosorbent assays: Theoretical considerations. Journal of Immunological Methods. https://doi.org/10.1016/j.jim.2012.02.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.