CoChat

A multi-center ring trial of allergen analysis using fluorescent multiplex array technology

Open access
King, Eva M., Filep, Stephanie, Smith, Bryan, Platts-Mills, Thomas, Hamilton, Robert G., Schmechel, Detlef, Sordillo, Joanne E., Milton, Donald, van Ree, Ronald, Krop, Esmeralda J.M., Heederik, Dick J.J., Metwali, Nervana, Thorne, Peter S., Zeldin, Darryl C., Sever, Michelle L., Calatroni, Agustin, Arbes, Samuel J., Mitchell, Herman E., Chapman, Martin D. · 2013 · Journal of Immunological Methods
Cited by 41

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background Consistent performance of allergen assays is essential to ensure reproducibility of exposure assessments for investigations of asthma and occupational allergic disease. This study evaluated intra- and inter-laboratory reproducibility of a fluorescent multiplex array, which simultaneously measures eight indoor allergens in a single reaction well. Methods A multi-center study was performed in nine laboratories in the US and Europe to determine the inter-laboratory variability of an 8-plex array for dust mite, cat, dog, rat, mouse and cockroach allergens. Aliquots of 151 dust extract samples were sent to participating centers and analyzed by each laboratory on three separate occasions. Agreement within and between laboratories was calculated by the concordance correlation coefficient (CCC). Results Results were obtained for over 32,000 individual allergen measurements. Levels covered a wide range for all allergens from below the lower limit of detection (LLOD=0.1 - 9.8ng/ml) to higher than 6800ng/ml for all allergens except Mus m 1, which was up to 1700ng/ml. Results were reproducible within as well as between laboratories. Within laboratories, 94% of CCC were ≥0.90, and 80% of intra-laboratory results fell within a 10% coefficient of variance (CV%). Results between laboratories also showed highly significant positive correlations for all allergens (∼0.95, p<0.001). Overall means of results were comparable, and inter-laboratory CV% for all allergens except Rat n 1 ranged between 17.6% and 26.6%. Conclusion The data indicate that performance criteria for fluorescent multiplex array technology are reproducible within and between laboratories. Multiplex technology provides standardized and consistent allergen measurements that will streamline environmental exposure assessments in allergic disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jim.2012.09.015

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 41

Metadata

Authors
King, E. M., Filep, S., Smith, B., Platts-Mills, T., Hamilton, R. G., Schmechel, D., Sordillo, J. E., Milton, D., van Ree, R., Krop, E. J. M., Heederik, D. J. J., Metwali, N., Thorne, P. S., Zeldin, D. C., Sever, M. L., Calatroni, A., Arbes, S. J., Mitchell, H. E., & Chapman, M. D.
Venue
Journal of Immunological Methods
Publisher
Elsevier BV
Published
2013-01
Volume
387
Issue
1-2
Pages
89-95
ISSN
0022-1759 (ISSN-L)
OpenAlex
W2043824121
Cited by
41
References
5
FWCI
2.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A multi-center ring trial of allergen analysis using fluorescent multiplex array technology. https://app.cochat.ai/papers/10.1016/j.jim.2012.09.015
The paper
King, E. M., Filep, S., Smith, B., Platts-Mills, T., Hamilton, R. G., Schmechel, D., Sordillo, J. E., Milton, D., van Ree, R., Krop, E. J. M., Heederik, D. J. J., Metwali, N., Thorne, P. S., Zeldin, D. C., Sever, M. L., Calatroni, A., Arbes, S. J., Mitchell, H. E., & Chapman, M. D. (2013). A multi-center ring trial of allergen analysis using fluorescent multiplex array technology. Journal of Immunological Methods. https://doi.org/10.1016/j.jim.2012.09.015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.