Measuring affinity constants of 1450 monoclonal antibodies to peptide targets with a microarray-based label-free assay platform
Open accessThe DOI matches its Crossref record.
Abstract
Monoclonal antibodies (mAbs) are major reagents for research and clinical diagnosis. For their inherently high specificities to intended antigen targets and thus low toxicity in general, they are pursued as one of the major classes of new drugs. Yet binding properties of most monoclonal antibodies are not well characterized in terms of affinity constants and how they vary with presentations and/or conformational isomers of antigens, buffer compositions, and temperature. We here report a microarray-based label-free assay platform for high-throughput measurements of monoclonal antibody affinity constants to antigens immobilized on solid surfaces. Using this platform we measured affinity constants of over 1,410 rabbit monoclonal antibodies and 46 mouse monoclonal antibodies to peptide targets that are immobilized through a terminal cysteine residue to a glass surface. The experimentally measured affinity constants vary from 10 pM to 200 pM with the median value at 66 pM. We compare results of the microarray-based platform with those of a benchmarking surface-plasmon-resonance-based (SPR) sensor (Biacore 3000).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nonspecific Binding—Fundamental Concepts and Consequences for Biosensing Applications
Frutiger, A., Tanno, A., Hwu, S., Tiefenauer, R. F., Vörös, J., & Nakatsuka, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00044 · Cited by 278
Padín-González, E., Lancaster, P., Bottini, M., Gasco, P., Tran, L., Fadeel, B., Wilkins, T., & Monopoli, M. P. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.882363 · Cited by 166
Biofunctionalization of Multiplexed Silicon Photonic Biosensors
Puumala, L. S., Grist, S. M., Morales, J. M., Bickford, J. R., Chrostowski, L., Shekhar, S., & Cheung, K. C. (2022) · Biosensors · doi:10.3390/bios13010053 · Cited by 55
Ojima-Kato, T., Nagai, S., & Nakano, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-14277-0 · Cited by 44
Nanobody inhibitors of Plexin-B1 identify allostery in plexin–semaphorin interactions and signaling
Cowan, R., Trokter, M., Oleksy, A., Fedorova, M., Sawmynaden, K., Worzfeld, T., Offermanns, S., Matthews, D., Carr, M. D., & Hall, G. (2023) · Journal of Biological Chemistry · doi:10.1016/j.jbc.2023.104740 · Cited by 11
Metadata
- Authors
- Landry, J. P., Ke, Y., Yu, G.-L., & Zhu, X. D.
- Venue
- Journal of Immunological Methods
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 417
- Pages
- 86-96
- ISSN
- 0022-1759 (ISSN-L)
- OpenAlex
- W2106044600
- Cited by
- 157
- References
- 0
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring affinity constants of 1450 monoclonal antibodies to peptide targets with a microarray-based label-free assay platform. https://app.cochat.ai/papers/10.1016/j.jim.2014.12.011
- The paper
- Landry, J. P., Ke, Y., Yu, G.-L., & Zhu, X. D. (2015). Measuring affinity constants of 1450 monoclonal antibodies to peptide targets with a microarray-based label-free assay platform. Journal of Immunological Methods. https://doi.org/10.1016/j.jim.2014.12.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.