The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly sensitive ozone and hydrogen sensors based on perovskite microcrystals directly grown on electrodes
Open accessAbstract
Highly-sensitive and stable ozone and hydrogen sensing elements were fabricated based on well-crystalline rounded cube-shaped CsPbBr3 microcrystals, synthesized by a facile solution process performed under ambient conditions. It is shown that such elements demonstrate enhanced room temperature gas sensing ability compared to the previously reported metal halide and oxide-based ones. Electrical measurements performed on these sensing components revealed high sensitivity to ultra-low ozone and hydrogen concentrations, namely 4 ppb and 1 ppm respectively, as well as a remarkable repeatability, even after a few months of storage in ambient conditions. Both ozone and hydrogen sensors were self-activated, as they did not require the use of UV or heating external stimuli to operate, and exhibited fast detection and short restoration times. All such attractive properties along with the simple fabrication process could provide an easy, efficient and low-cost technology for the realization of future gas sensing devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The sensor demonstrated high sensitivity to ultra-low ozone concentrations (4 ppb) and remarkable repeatability, even after several months of storage in ambient conditions.”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [159]
In the citing paper
“To improve sensitivity and stability, Argyrou et al. [159] fabricated a stable CsPbBr 3 perovskite-based ozone sensor using a simple solution process conducted under ambient conditions.”
From Design Strategies and Emerging Applications of Perovskite-Based Sensors (2025) · cites this paper as [159]
Citations
Cites
The effects of ozone on human health
Nuvolone, D., Petri, D., & Voller, F. (2018) · Environmental Science and Pollution Research · doi:10.1007/s11356-017-9239-3 · Cited by 619
Research works printed but not linked: 76
- Tsujita, 2005, Sensor Actuator B Chem, 110, 304, 10.1016/j.snb.2005.02.008 · DOI
- Su, 2020, ACS Nano, 14, 6067, 10.1021/acsnano.0c01804 · DOI
- Sadik, 2004, J Environ Monit, 6, 513, 10.1039/b401794n · DOI
- Baruah, 2009, Environ Chem Lett, 7, 191, 10.1007/s10311-009-0228-8 · DOI
- Liu, 2012, Sensors, 12, 9635, 10.3390/s120709635 · DOI
- Hübert, 2011, Sensor Actuator B Chem, 157, 329, 10.1016/j.snb.2011.04.070 · DOI
- Korotcenkov, 2012, Sensor Actuator B Chem, 161, 28, 10.1016/j.snb.2011.12.003 · DOI
- Jyoti, 2004, Biochem Eng J, 18, 9, 10.1016/S1369-703X(03)00116-5 · DOI
- Prabha, 2015, Trends in Biosciences, 8, 4031
- Rowe, 1983, Environ Int, 9, 515, 10.1016/0160-4120(83)90008-9 · DOI
- Novelli, 1999, J Geophys Res, 104, 30427, 10.1029/1999JD900788 · DOI
- 2006, vol. 23
- Burch, 1990, Catal Lett, 5, 55, 10.1007/BF00772093 · DOI
- Smirnov, 2014, Int J Hydrogen Energy, 39, 10748, 10.1016/j.ijhydene.2014.04.150 · DOI
- Eliezer, 2000, Mater Sci Eng, A, 280, 220, 10.1016/S0921-5093(99)00670-X · DOI
- Sharma, 2015, Renew Sustain Energy Rev, 43, 1151, 10.1016/j.rser.2014.11.093 · DOI
- Kandyla, 2014, Mater Lett, 119, 51, 10.1016/j.matlet.2013.12.104 · DOI
- Kostopoulou, 2018, J Mater Chem, 6, 9765, 10.1039/C8TA01964A · DOI
- Kostopoulou, 2019, Nanophotonics, 8, 1607, 10.1515/nanoph-2019-0119 · DOI
- Zhao, 2014, Chem Commun, 50, 1605, 10.1039/c3cc48522f · DOI
- Zhaohua Zhu, 2018, J Mater Chem C, 6, 10121
- Fang, 2016, Sci Adv, 2
- Xu, 2016, J Mater Chem C, 4, 9651, 10.1039/C6TC01075J · DOI
- Fu, 2018, RSC Adv, 8, 390, 10.1039/C7RA11149E · DOI
- Chen, 2018, Small, 14, 1702571, 10.1002/smll.201702571 · DOI
- Lin, 2018, ACS Appl Mater Interfaces, 10, 23335, 10.1021/acsami.8b06329 · DOI
- Fergus, 2007, Sensor Actuator B Chem, 123, 1169, 10.1016/j.snb.2006.10.051 · DOI
- Aamir, 2016, Mater Lett, 183, 135, 10.1016/j.matlet.2016.07.066 · DOI
- Aamir, 2017, Eur J Inorg Chem, 2017, 3755, 10.1002/ejic.201700660 · DOI
- Zhou, 2019, Energy Environ Sci, 12, 1495, 10.1039/C8EE03559H · DOI
- Li, 2017, Small, 13, 1603996, 10.1002/smll.201603996 · DOI
- Shan, 2017, J Mater Chem C, 5, 4565, 10.1039/C6TC05578H · DOI
- Huang, 2017, ACS Energy Lett, 2, 2071, 10.1021/acsenergylett.7b00547 · DOI
- Kakavelakis, 2018, ACS Sens, 3, 135, 10.1021/acssensors.7b00761 · DOI
- Gagaoudakis, 2020, J Phys Mater, 3
- Brintakis, 2019, Nanoscale Adv, 1, 2699, 10.1039/C9NA00219G · DOI · Paper page
- Zhang, 2018, Angew Chem Int Ed, 57, 3337, 10.1002/anie.201710869 · DOI
- Cha, 2017, J Phys Chem Lett, 8, 565, 10.1021/acs.jpclett.6b02763 · DOI
- Li, 2021, Sensor Actuator B Chem, 345, 130298, 10.1016/j.snb.2021.130298 · DOI
- Thirumalairajan, 2014, ACS Appl Mater Interfaces, 6, 21739, 10.1021/am507158z · DOI
- Shankar, 2015, Sci Lett J, 4, 126
- Guérin, 2006, Sensor Actuator B Chem, 119, 327, 10.1016/j.snb.2005.12.005 · DOI
- Kostopoulou, 2020, J Power Sources Adv, 3, 100015, 10.1016/j.powera.2020.100015 · DOI
- Gurlo, 2007, Angew Chem Int Ed, 46, 3826, 10.1002/anie.200602597 · DOI
- Sebastian, 2015, Phys Rev B, 92, 235210, 10.1103/PhysRevB.92.235210 · DOI
- Kang, 2017, J Phys Chem Lett, 8, 489, 10.1021/acs.jpclett.6b02800 · DOI
- Seth, 2019, ACS Energy Lett, 4, 1610, 10.1021/acsenergylett.9b00849 · DOI
- Shi, 2014, Phys Rev B, 90, 174103, 10.1103/PhysRevB.90.174103 · DOI
- Li, 2017, Energy Environ Sci, 10, 1234, 10.1039/C7EE00358G · DOI
- Meggiolaro, 2019, ACS Energy Lett, 4, 779, 10.1021/acsenergylett.9b00247 · DOI
- Chen, 2020, J Appl Phys, 128
- Pan, 2019, Angew Chem, 131, 16223, 10.1002/ange.201909109 · DOI
- Chen, 2020, J Am Chem Soc, 142, 6117, 10.1021/jacs.9b13396 · DOI
- Merinov, 2009, J Chem Phys, 130, 194707
- Hermet, 2013, Phys Rev B, 87, 104303, 10.1103/PhysRevB.87.104303 · DOI
- Egger, 2015, Angew Chem Int Ed, 54, 12437, 10.1002/anie.201502544 · DOI
- Zhu, 2015, Sensor Actuator B Chem, 214, 56, 10.1016/j.snb.2015.03.017 · DOI
- Kang, 2017, Sensor Actuator B Chem, 241, 1203, 10.1016/j.snb.2016.10.012 · DOI
- Gavalas, 2019, Mater Sci Semicond Process, 89, 116, 10.1016/j.mssp.2018.09.008 · DOI
- Wu, 2018, Sensor Actuator B Chem, 273, 1713, 10.1016/j.snb.2018.07.075 · DOI
- Wu, 2018, Sensor Actuator B Chem, 255, 117, 10.1016/j.snb.2017.08.055 · DOI
- Shao, 2018, Sensor Actuator B Chem, 258, 937, 10.1016/j.snb.2017.11.166 · DOI
- Jayachandiran, 2020, Adv Compos Hybrid Mater, 3, 16, 10.1007/s42114-020-00134-8 · DOI
- Park, 2020, J Hazard Mater, 394, 122516, 10.1016/j.jhazmat.2020.122516 · DOI
- Joshi, 2019, Microchim Acta, 186, 418, 10.1007/s00604-019-3532-4 · DOI
- da Silva, 2017, Sensor Actuator B Chem, 240, 573, 10.1016/j.snb.2016.08.158 · DOI
- Ren, 2016, J Mater Chem, 4, 2236, 10.1039/C5TA06917C · DOI
- Liu, 2015, Sensor Actuator B Chem, 211, 537, 10.1016/j.snb.2015.01.129 · DOI
- Esfandiar, 2014, Int J Hydrogen Energy, 39, 8169, 10.1016/j.ijhydene.2014.03.117 · DOI
- Ling, 2016, Sensor Actuator B Chem, 227, 438, 10.1016/j.snb.2015.12.077 · DOI
- Sarkar, 2015, Nano Lett, 15, 2852, 10.1021/nl504454u · DOI
- Huang, 2012, Sensor Actuator B Chem, 174, 389, 10.1016/j.snb.2012.08.065 · DOI
- Prakash, 2018, Sensor Actuator B Chem, 277, 665, 10.1016/j.snb.2018.09.002 · DOI
- Kumar, 2017, Nanotechnology, 28, 365502, 10.1088/1361-6528/aa7cad · DOI
- Achary, 2020, Journal of Hydrogen Energy, 45, 5073, 10.1016/j.ijhydene.2019.12.048 · DOI
- Xia, 2016, Sensor Actuator B Chem, 234, 192, 10.1016/j.snb.2016.04.110 · DOI
Cited by
Sorted by citations
Design Strategies and Emerging Applications of Perovskite-Based Sensors
Li, Y., Ding, Y., Sun, J., Tan, S., Li, Y., Wang, X., Cai, J., Bai, J., Lv, X., Guo, W., et al. (2025) · SmartMat · doi:10.1002/smm2.70022 · Cited by 41
Zhang, H., Zhang, L., Zhao, Z., Xin, W., Niu, J., He, J., & Jiao, W. (2024) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2023.135238 · Cited by 28
Metadata
- Authors
- Argyrou, A., Brintakis, K., Kostopoulou, A., Gagaoudakis, E., Demeridou, I., Binas, V., Kiriakidis, G., & Stratakis, E.
- Affiliations
- University of Crete (GR)
- FORTH Institute of Electronic Structure and Laser (GR)
- Corresponding author
- Brintakis, Konstantinos
- Stratakis, Emmanuel
- ORCID
- Venue
- Journal of Materiomics
- Publisher
- Elsevier BV
- Published
- 2022-03
- Volume
- 8
- Issue
- 2
- Pages
- 446-453
- ISSN
- 2352-8478 (ISSN-L)
- OpenAlex
- W3184142244
- Cited by
- 31
- References
- 1
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 4 · 2023: 10 · 2022: 5
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Materiomics (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- State Scholarships Foundation (MIS-5033021)
- University of Crete
- Hellenic Foundation for Research and Innovation (1179)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Physical Sciences › Environmental Science › Environmental Engineering › Air Quality Monitoring and Forecasting
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- ozone detection, hydrogen detection, perovskite microcrystals, CsPbBr3, solution-processed perovskites, room-temperature gas sensing, low-concentration gas detection, sensor stability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly sensitive ozone and hydrogen sensors based on perovskite microcrystals directly grown on electrodes. https://app.cochat.ai/papers/10.1016/j.jmat.2021.07.002
- The paper
- Argyrou, A., Brintakis, K., Kostopoulou, A., Gagaoudakis, E., Demeridou, I., Binas, V., Kiriakidis, G., & Stratakis, E. (2022). Highly sensitive ozone and hydrogen sensors based on perovskite microcrystals directly grown on electrodes. Journal of Materiomics. https://doi.org/10.1016/j.jmat.2021.07.002