The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Ultra high molecular weight polyethylene: Mechanics, morphology, and clinical behavior
Open accessAbstract
Ultra high molecular weight polyethylene (UHMWPE) is a semicrystalline polymer that has been used for over four decades as a bearing surface in total joint replacements. The mechanical properties and wear properties of UHMWPE are of interest with respect to the in vivo performance of UHMWPE joint replacement components. The mechanical properties of the polymer are dependent on both its crystalline and amorphous phases. Altering either phase (i.e., changing overall crystallinity, crystalline morphology, or crosslinking the amorphous phase) can affect the mechanical behavior of the material. There is also evidence that the morphology of UHMWPE, and, hence, its mechanical properties evolve with loading. UHMWPE has also been shown to be susceptible to oxidative degradation following gamma radiation sterilization with subsequent loss of mechanical properties. Contemporary UHMWPE sterilization methods have been developed to reduce or eliminate oxidative degradation. Also, crosslinking of UHMWPE has been pursued to improve the wear resistance of UHMWPE joint components. The 1st generation of highly crosslinked UHMWPEs have resulted in clinically reduced wear; however, the mechanical properties of these materials, such as ductility and fracture toughness, are reduced when compared to the virgin material. Therefore, a 2nd generation of highly crosslinked UHMWPEs are being introduced to preserve the wear resistance of the 1st generation while also seeking to provide oxidative stability and improved mechanical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030
Kurtz, S., Ong, K., Lau, E., Mowat, F., & Halpern, M. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200704000-00012 · Cited by 8,698
A three-dimensional constitutive model for the large stretch behavior of rubber elastic materials
Arruda, E. M., & Boyce, M. C. (1993) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(93)90013-6 · Cited by 3,239
Mechanical behavior of materials
(1990) · Choice Reviews Online · doi:10.5860/choice.28-0309 · Cited by 1,843
Mechanical Behavior of Materials: Engineering Methods for Deformation, Fracture, and Fatigue
Dowling, N. E. (1993) · Virtual Defense Library (Ministerio de Defensa) · Cited by 1,579
Kurtz, S. M., Lau, E., Ong, K., Zhao, K., Kelly, M., & Bozic, K. J. (2009) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-009-0834-6 · Cited by 1,502
Constitutive modeling of the large strain time-dependent behavior of elastomers
BERGSTROM, J. (1998) · Journal of the Mechanics and Physics of Solids · doi:10.1016/s0022-5096(97)00075-6 · Cited by 1,147
Kurtz, S. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00053-8 · Cited by 847
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667 · cited 1×
“The wear debris can trigger an elaborate immune response which results in osteoclasts resorbing bone around the implant, which can lead to periprosthetic osteolytic implant loosening (Ingham and Fisher, 2005; Abu-Amer et al., 2007).”
BackgroundMuratoglu, O. K., Bragdon, C. R., O’Connor, D., Jasty, M., & Harris, W. H. (2001) · The Journal of Arthroplasty · doi:10.1054/arth.2001.20540 · Cited by 637
Structure and plastic deformation of polyethylene
Lin, L., & Argon, A. S. (1994) · Journal of Materials Science · doi:10.1007/bf01162485 · Cited by 574
Abu-Amer, Y., Darwech, I., & Clohisy, J. C. (2007) · Arthritis Research & Therapy · doi:10.1186/ar2170 · Cited by 534
Fehring, T. K., Odum, S. M., Griffin, W. L., Mason, J. B., & McCoy, T. H. (2007) · The Journal of Arthroplasty · doi:10.1016/j.arth.2007.04.014 · Cited by 487
Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
Muratoglu, O. K., Bragdon, C. R., O’Connor, D., Jasty, M., Harris, W. H., Gul, R. M., & Garry, F. J. M. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00039-3 · Cited by 455
A constitutive model for the nonlinear viscoelastic viscoplastic behavior of glassy polymers
Hasan, O. A., & Boyce, M. C. (1995) · Polymer Engineering & Science · doi:10.1002/pen.760350407 · Cited by 370
α-Tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear
Oral, E., Wannomae, K. K., Hawkins, N., Harris, W. H., & Muratoglu, O. K. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.048 · Cited by 301
Ultra-high molecular weight polyethylene. The material and its use in total joint implants.
Li, S., & Burstein, A. H. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199407000-00020 · Cited by 291
Properties of crosslinked ultra-high-molecular-weight polyethylene
Lewis, G. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00195-2 · Cited by 288
Pruitt, L. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.022 · Cited by 282
McKELLOP, H., SHEN, F.-W., LU, B., CAMPBELL, P., & SALOVEY, R. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200012000-00004 · Cited by 264
Drawing and extrusion of semi-crystalline polymers
Peterlin, A. (1987) · Colloid & Polymer Science · doi:10.1007/bf01412215 · Cited by 251
Galeski, A., Bartczak, Z., Argon, A. S., & Cohen, R. E. (1992) · Macromolecules · doi:10.1021/ma00047a023 · Cited by 247
The UHMWPE Handbook: Ultra-High Molecular Weight Polyethylene in Total Joint Replacement
Kurtz, S. M. (2004) · Cited by 219
Baker, D., Bellare, A., & Pruitt, L. A. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10606 · Cited by 215
Butler, M. F., Donald, A. M., & Ryan, A. J. (1998) · Polymer · doi:10.1016/s0032-3861(97)00226-7 · Cited by 213
Bergström, J. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00367-2 · Cited by 195
Wear of Gamma-Crosslinked Polyethylene Acetabular Cups Against Roughened Femoral Balls
McKellop, H., Shen, F.-W., DiMaio, W., & Lancaster, J. G. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199912000-00008 · Cited by 184
Simulation of large-strain plastic-deformation and texture evolution in high-density polyethylene
Lee, B. J., Argon, A. S., Parks, D. M., Ahzi, S., & Bartczak, Z. (1993) · Polymer · doi:10.1016/0032-3861(93)90039-d · Cited by 183
Kurtz, S. M., Villarraga, M. L., Herr, M., Bergström, J., Rimnac, C. M., & Edidin, A. A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00102-3 · Cited by 179
Self-citationPost-irradiation aging of ultra-high molecular weight polyethylene.
Rimnac, C. M., Klein, R. W., Betts, F., & Wright, T. M. (1994) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199407000-00014 · Cited by 178
Self-citationA dislocation model for yield in polyethylene
Young, R. J. (1974) · Philosophical Magazine · doi:10.1080/14786439808206535 · Cited by 161
The effect of α-tocopherol on the oxidation and free radical decay in irradiated UHMWPE
Oral, E., Rowell, S. L., & Muratoglu, O. K. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.017 · Cited by 144
Comparative fatigue behavior and toughness of remelted and annealed highly crosslinked polyethylenes
Medel, F. J., Peña, P., Cegoñino, J., Gómez‐Barrena, E., & Puértolas, J. A. (2007) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30807 · Cited by 136
Goldman, M., Gronsky, R., Ranganathan, R., et al. (1996) · Polymer · doi:10.1016/0032-3861(96)89386-4 · Cited by 131
Simis, K., Bistolfi, A., Bellare, A., et al. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.033 · Cited by 130
Gencur, S. J., Rimnac, C. M., & Kurtz, S. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.010 · Cited by 130
Self-citationDegradation of mechanical behavior in UHMWPE after natural and accelerated aging
Edidin, A. A., Jewett, C. W., Kalinowski, A., Kwarteng, K. B., & Kurtz, S. M. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00021-1 · Cited by 129
Effect of annealing and temperature on the morphological structure of polymers
Fischer, E. W. (1972) · Pure and Applied Chemistry · doi:10.1351/pac197231010113 · Cited by 118
Meyer, R. W., & Pruitt, L. A. (2001) · Polymer · doi:10.1016/s0032-3861(00)00626-1 · Cited by 107
Monte Carlo Modeling of Amorphous Polymer Deformation: Evolution of Stress with Strain
Chui, C., & Boyce, M. C. (1999) · Macromolecules · doi:10.1021/ma9815399 · Cited by 102
IN VIVO DEGRADATION OF POLYETHYLENE LINERS AFTER GAMMA STERILIZATION IN AIR
Kurtz, S. M., Rimnac, C. M., Hozack, W. J., Turner, J. A., Marcolongo, M. S., Goldberg, V. M., Kraay, M. J., & Edidin, A. A. (2005) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.d.02111 · Cited by 101
Self-citationBergström, J., Rimnac, C. M., & Kurtz, S. M. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00514-8 · Cited by 94
Self-citationA study of the nanostructure and tensile properties of ultra-high molecular weight polyethylene
Turell, M. B., & Bellare, A. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.027 · Cited by 91
The Porous-Coated Anatomic Total Hip Prosthesis: Failure of the Metal-Backed Acetabular Component*
Astion, D. J., Saluan, P. M., Stulberg, B. N., Rimnac, C. M., & Li, S. (1996) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199605000-00016 · Cited by 88
Self-citationFatigue Strength of Polyethylene After Sterilization by Gamma Irradiation or Ethylene Oxide
Ries, M. D., Weaver, K. D., Rose, R. M., et al. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199612000-00008 · Cited by 84
Séguéla, R. (2002) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.10118 · Cited by 79
Kurtz, S. M., Rimnac, C. M., Pruitt, L. A., Jewett, C. W., Goldberg, V., & Edidin, A. A. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00178-7 · Cited by 67
Self-citationBracco, P., Brunella, V., Cortemiglia, M. P. L. D., Prever, E. M. B. D., Zanetti, M., & Costa, L. (2006) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2006.08.002 · Cited by 60
Gencur, S. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00277-1 · Cited by 58
The effects of morphology on the yield behaviour of polyethylene copolymers
Сироткин, Р. О., & Brooks, N. W. J. (2001) · Polymer · doi:10.1016/s0032-3861(00)00762-x · Cited by 29
Sobieraj, M. C., Kurtz, S. M., & Rimnac, C. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.04.008 · Cited by 27
Self-citationThe effect of patient gait on the material properties of UHMWPE in hip replacements
Davey, S., Orr, J. F., Buchanan, F., et al. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.01.007 · Cited by 23
Screw dislocation model for yield in polyethylene
Young, R. J. (1988) · Cited by 19
Mechanisms of Crosslinking and Oxidative Degradation of UHMWPE
Costa, L., & Bracco, P. (2004) · Elsevier eBooks · doi:10.1016/b978-012429851-4/50012-7 · Cited by 10
Mishra, S. R., Viano, A. M., Fore, N., Lewis, G., & Ray, A. (2003) · PubMed · Cited by 5
Cited by
Brannigan, R. P., & Dove, A. P. (2017) · Biomaterials Science · doi:10.1039/c6bm00584e · Cited by 334
Metadata
- Authors
- Sobieraj, M. C., & Rimnac, C. M.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2009-10
- Volume
- 2
- Issue
- 5
- Pages
- 433-443
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2033862374
- Cited by
- 289
- References
- 54
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.