The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Mechanical characterization of brain tissue in compression at dynamic strain rates
Open accessAbstract
Traumatic brain injury (TBI) occurs when local mechanical load exceeds certain tolerance levels for brain tissue. Extensive research has been done previously for brain matter experiencing compression at quasistatic loading; however, limited data is available to model TBI under dynamic impact conditions. In this research, an experimental setup was developed to perform unconfined compression tests and stress relaxation tests at strain rates ≤90/s. The brain tissue showed a stiffer response with increasing strain rates, showing that hyperelastic models are not adequate. Specifically, the compressive nominal stress at 30% strain was 8.83 ± 1.94, 12.8 ± 3.10 and 16.0 ± 1.41 kPa (mean ± SD) at strain rates of 30, 60 and 90/s, respectively. Relaxation tests were also conducted at 10%-50% strain with the average rise time of 10 ms, which can be used to derive time dependent parameters. Numerical simulations were performed using one-term Ogden model with initial shear modulus μ(o)=6.06±1.44, 9.44 ± 2.427 and 12.64 ± 1.227 kPa (mean ± SD) at strain rates of 30, 60 and 90/s, respectively. A separate set of bonded and lubricated tests were also performed under the same test conditions to estimate the friction coefficient μ, by adopting combined experimental-computational approach. The values of μ were 0.1 ± 0.03 and 0.15 ± 0.07 (mean ± SD) at 30 and 90/s strain rates, respectively, indicating that pure slip conditions cannot be achieved in unconfined compression tests even under fully lubricated test conditions. The material parameters obtained in this study will help to develop biofidelic human brain finite element models, which can subsequently be used to predict brain injuries under impact conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Non-linear elastic deformations
Ogden, R. (1984) · Engineering Analysis with Boundary Elements · doi:10.1016/0955-7997(84)90049-3 · Cited by 3,489
Ogden, R. W. (1972) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1972.0026 · Cited by 2,979
Nonlinear Solid Mechanics: A Continuum Approach for Engineering
Holzapfel, G. A. (2000) · Cited by 2,700
A New Constitutive Relation for Rubber
Gent, A. N. (1996) · Rubber Chemistry and Technology · doi:10.5254/1.3538357 · Cited by 1,850
Non-linear elastic deformations
Ogden, R. W. (1984) · Engineering Analysis · doi:10.1016/0264-682x(84)90061-3 · Cited by 1,537
Ibrahimbegovic, A. (2009) · Solid Mechanics and its Applications · doi:10.1007/978-90-481-2331-5 · Cited by 1,112
Elasticity of soft tissues in simple elongation
Fung, Y. (1967) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1967.213.6.1532 · Cited by 1,029
Fitting hyperelastic models to experimental data
Ogden, R. W., Saccomandi, G., & Sgura, I. (2004) · Computational Mechanics · doi:10.1007/s00466-004-0593-y · Cited by 775
Pseudoelasticity of arteries and the choice of its mathematical expression
Fung, Y. C., Fronek, K., & Patitucci, P. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.5.h620 · Cited by 688
Cited by
Mechanical characterization of human brain tissue
Budday, S., Sommer, G., Birkl, C., Langkammer, C., Haybaeck, J., Kohnert, J., Bauer, M., Paulsen, F., Steinmann, P., Kuhl, E., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.036 · Cited by 656
Fifty Shades of Brain: A Review on the Mechanical Testing and Modeling of Brain Tissue
Budday, S., Ovaert, T. C., Holzapfel, G. A., Steinmann, P., & Kuhl, E. (2020) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-019-09352-w · Cited by 469
Mechanics of the brain: perspectives, challenges, and opportunities
Goriely, A., Geers, M. G. D., Holzapfel, G. A., Jayamohan, J., Jérusalem, A., Sivaloganathan, S., Squier, W., van Dommelen, J. A. W., Waters, S., & Kuhl, E. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0662-4 · Cited by 371
Mechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
Viscoelastic parameter identification of human brain tissue
Budday, S., Sommer, G., Holzapfel, G. A., Steinmann, P., & Kuhl, E. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.07.014 · Cited by 178
Metadata
- Authors
- Rashid, B., Destrade, M., & Gilchrist, M. D.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2012-06
- Volume
- 10
- Pages
- 23-38
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2153015714
- Cited by
- 426
- References
- 68
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical characterization of brain tissue in compression at dynamic strain rates. https://app.cochat.ai/papers/10.1016/j.jmbbm.2012.01.022
- The paper
- Rashid, B., Destrade, M., & Gilchrist, M. D. (2012). Mechanical characterization of brain tissue in compression at dynamic strain rates. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2012.01.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.