The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Characterizing the ex vivo mechanical properties of synthetic polypropylene surgical mesh
Abstract
The use of synthetic polypropylene mesh for hernia surgical repair and the correction of female pelvic organ prolapse have been controversial due to increasing post-operative complications, including mesh erosion, chronic pain, infection and support failure. These morbidities may be related to a mismatch of mechanical properties between soft tissues and the mesh. The aim of this study was to gain a better understanding of the biomechanical behavior of Prolene polypropylene mesh (Ethicon, Sommerville, NJ, USA), which is widely used for a variety of surgical repair procedures. The stiffness and permanent deformation of Prolene mesh were compared in different directions by performing uniaxial tensile failure tests, cyclic and creep tests at simulated physiological loads in the coursewise (0°), walewise (90°) and the diagonal (45°) directions. Failure tests suggest that the mechanical properties of the mesh is anisotropic; with response at 0° being the most compliant while 90° was the stiffest. Irreversible deformation and viscoelastic behavior were observed in both cyclic and creep tests. The anisotropic property may be relevant to the placement of mesh in surgery to maximize long term mesh performance. The considerable permanent deformation may be associated with an increased risk of post-operative support failure.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
When polypropylene mesh undergoes cyclical testing, its stress/strain curves show a rightward shift of the hysteresis loop, indicating permanent elongation of the mesh and possible long-term viscous creep.
“When undergoing cyclical testing, the stress/strain curves for PP show a rightward shift of the hysteresis loop, indicating permanent elongation of the mesh and possible long‐term viscous creep [56].”
From How Can We Improve the Assessment and Indifferent Outcomes From Pelvic Organ Prolapse Management From Conservative and Surgical Therapies? ICI‐RS 2025 (2026) · cites this paper as [56]
Citations
Cites
Long-term Complications Associated With Prosthetic Repair of Incisional Hernias
Leber, G. E. (1998) · Archives of Surgery · doi:10.1001/archsurg.133.4.378 · Cited by 917
Classification of biomaterials and their related complications in abdominal wall hernia surgery
Amid, P. K. (1997) · Hernia · doi:10.1007/bf02426382 · Cited by 754
Anterior Colporrhaphy versus Transvaginal Mesh for Pelvic-Organ Prolapse
Altman, D., Väyrynen, T., Engh, M. E., Axelsen, S. M., & Falconer, C. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009521 · Cited by 562
Normal Intraabdominal Pressure in Healthy Adults
Cobb, W. S., Burns, J. M., Kercher, K. W., Matthews, B. D., Norton, H. J., & Heniford, B. T. (2005) · Journal of Surgical Research · doi:10.1016/j.jss.2005.06.015 · Cited by 462
Brown, C. M., & Finch, G. (2010) · Annals of The Royal College of Surgeons of England · doi:10.1308/003588410x12664192076296 · Cited by 386
Impact of Polymer Pore Size on the Interface Scar Formation in a Rat Model
Klinge, U., Klosterhalfen, B., Birkenhauer, V., Junge, K., Conze, J., & Schumpelick, V. (2002) · Journal of Surgical Research · doi:10.1006/jsre.2002.6358 · Cited by 340
Ballooning of the levator hiatus
Dietz, H. P., Shek, C., León-Luis, J. A. D., & Steensma, A. B. (2008) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.5355 · Cited by 318
Self-citationJunge, K., Klinge, U., Prescher, A., Giboni, P., Niewiera, M., & Schumpelick, V. (2001) · Hernia · doi:10.1007/s100290100019 · Cited by 277
Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall
Klinge, U., Klosterhalfen, B., Conze, J., Limberg, W., Obolenski, B., Öttinger, A. P., & Schumpelick, V. (2002) · The European Journal of Surgery · doi:10.1080/110241598750005138 · Cited by 271
Functional and morphologic properties of a modified mesh for inguinal hernia repair
Junge, K., Klinge, U., Rosch, R., Klosterhalfen, B., & Schumpelick, V. (2002) · World Journal of Surgery · doi:10.1007/s00268-002-6444-z · Cited by 164
Mesh Erosion After Abdominal Sacrocolpopexy
Kohli, N., Walsh, P. M., Roat, T. W., & Karram, M. M. (1998) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(98)00330-5 · Cited by 163
Mechanical properties of urogynecologic implant materials
Dietz, H. P., Vancaillie, P., Svehla, M., Walsh, W. R., Steensma, A. B., & Vancaillie, T. G. (2003) · International Urogynecology Journal · doi:10.1007/s00192-003-1041-8 · Cited by 134
Self-citationSimulating the deformation mechanisms of knitted fabric composites
Duhovic, M., & Bhattacharyya, D. (2006) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2005.12.029 · Cited by 119
Mesh augmentation during pelvic-floor reconstructive surgery: risks and benefits
Baeßler, K., & MAHER, C. F. (2006) · Current Opinion in Obstetrics & Gynecology · doi:10.1097/01.gco.0000242961.48114.b0 · Cited by 108
Hernández-Gascón, B., Peña, E., Melero, H., Pascual, G., Doblaré, M., Ginebra, M., Bellón, J. M., & Calvo, B. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.06.033 · Cited by 106
Anisotropic evaluation of synthetic surgical meshes
Saberski, E. R., Orenstein, S. B., & Novitsky, Y. W. (2010) · Hernia · doi:10.1007/s10029-010-0731-7 · Cited by 90
(2004) · Springer eBooks · doi:10.1007/978-3-642-18720-9 · Cited by 81
Mechanical properties of polypropylene mesh used in pelvic floor repair
Afonso, J. S., Martins, P. A. L. S., Girão, M. J. B. C., Jorge, R. N., Ferreira, A. J. M., Mascarenhas, T., Fernandes, A. A., Bernardes, J., Baracat, E. C., de Lima, G. R., et al. (2007) · International Urogynecology Journal · doi:10.1007/s00192-007-0446-1 · Cited by 80
Shepherd, J. P., Feola, A., Abramowitch, S. D., & Moalli, P. (2011) · International Urogynecology Journal · doi:10.1007/s00192-011-1616-8 · Cited by 80
Tensile properties of commonly used prolapse meshes
Jones, K. A., Feola, A., Meyn, L. A., Abramowitch, S. D., & Moalli, P. (2009) · International Urogynecology Journal · doi:10.1007/s00192-008-0781-x · Cited by 70
Evaluation of various prosthetic materials and newer meshes for hernia repairs
Doctor, H. G. (2006) · Journal of Minimal Access Surgery · doi:10.4103/0972-9941.27721 · Cited by 66
Anurov, M., Titkova, S., & Oettinger, A. P. (2011) · Hernia · doi:10.1007/s10029-011-0877-y · Cited by 59
Are postoperative activity restrictions evidence-based?
Guttormson, R., Tschirhart, J. M., Boysen, D. A., & Martinson, K. A. (2008) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2007.12.014 · Cited by 40
Evaluation of dynamic creep properties of surgical mesh prostheses—Uniaxial fatigue
Velayudhan, S., Martin, D. J., & Cooper-White, J. J. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31401 · Cited by 38
Biomechanical properties of raw meshes used in pelvic floor reconstruction
Krause, H. G., Bennett, M. B., Forwood, M. R., & Goh, J. T. W. (2008) · International Urogynecology Journal · doi:10.1007/s00192-008-0711-y · Cited by 38
Design and development of a novel intra-vaginal pressure sensor
Kruger, J., Hayward, L. M., Nielsen, P. M. F., Loiselle, D. S., & Kirton, R. S. (2013) · International Urogynecology Journal · doi:10.1007/s00192-013-2097-8 · Cited by 33
Self-citationBellón, J. M. (2009) · Cirugía Española · doi:10.1016/j.ciresp.2009.01.012 · Cited by 21
Role of the new lightweight prostheses in improving hernia repair
Bellón, J. M. (2009) · Cirugía Española (English Edition) · doi:10.1016/s2173-5077(09)70142-5 · Cited by 20
Visco-elastic mechanical properties of human abdominal fascia
Doneva, M., Stoytchev, S., Pashkouleva, D., Tsenova, V. S., & Hristoskova, R. (2009) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2008.11.003 · Cited by 11
Impact of vaginal synthetic prolapse meshes on the mechanics of the host tissue response
Feola, A. (2011) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 7
Flagged first, then by citations
Research works printed but not linked: 3
- Anurov, 2009, Effectiveness of experimental hernia repair depends on orientation of mesh implant with anisotropic structure, Hernia, 13
- Shek, 2012, How common is fixation failure after mesh kit surgery, Int. Urogynecol. J., 23, 154
- Wong, 2012, A comparison of two different forms of mesh fixation, Int. Urogynecol. J., 23, S124
Cited by
Sorted by citations
International guidelines for groin hernia management
The HerniaSurge Group (2018) · Hernia · doi:10.1007/s10029-017-1668-x · Cited by 2,431
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
Past, Present and Future of Surgical Meshes: A Review
Baylón, K., Rodríguez-Camarillo, P., Elı́as-Zúñiga, A., Elizondo, J. A. D., Gilkerson, R., & Lozano, K. (2017) · Membranes · doi:10.3390/membranes7030047 · Cited by 295
Mesh implants: An overview of crucial mesh parameters
Zhu, L. (2015) · World Journal of Gastrointestinal Surgery · doi:10.4240/wjgs.v7.i10.226 · Cited by 147
Domínguez‐Robles, J., Mancinelli, C., Mancuso, E., García‐Romero, I., Gilmore, B., Casettari, L., Larrañeta, E., & Lamprou, D. A. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12010063 · Cited by 160
Mechanical biocompatibility of highly deformable biomedical materials
Mazza, E., & Ehret, A. E. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.03.023 · Cited by 115
Physical structure and mechanical properties of knitted hernia mesh materials: A review
Sanbhal, N., Linli, M., Xu, R. Y., Khatri, A., & Wang, L. (2017) · Journal of Industrial Textiles · doi:10.1177/1528083717690613 · Cited by 55
Mancuso, E., Downey, C. L., Doxford‐Hook, E., Bryant, M., & Culmer, P. (2019) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34432 · Cited by 42
The failure of polypropylene surgical mesh in vivo
Taylor, D. M. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.08.041 · Cited by 36
Wei, D., Huang, Y., Liang, M., Ren, P., Tao, Y., Xu, L., Zhang, T., Ji, Z., & Zhang, Q. (2023) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2023.113159 · Cited by 33
Linli, M., Wang, F., Wang, L., Zou, T., Brochu, G., & Guidoin, R. (2015) · Materials · doi:10.3390/ma8125453 · Cited by 32
Micro-structural and Biaxial Creep Properties of the Swine Uterosacral–Cardinal Ligament Complex
Tan, T., Cholewa, N., Case, S. W., & Vita, R. D. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1661-z · Cited by 29
Mirjavan, M., Asayesh, A., & Jeddi, A. A. A. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.10.016 · Cited by 28
Biocompatibility study of poly(vinyl alcohol)-based electrospun scaffold for hernia repair
Molnár, K., Voniatis, C., Feher, D., Ferencz, A., Fónyad, L., Reiniger, L., Zrı́nyi, M., Wéber, G., & Jedlovszky‐Hajdú, A. (2018) · eXPRESS Polymer Letters · doi:10.3144/expresspolymlett.2018.58 · Cited by 24
Developing Repair Materials for Stress Urinary Incontinence to Withstand Dynamic Distension
Hillary, C. J., Román, S., Bullock, A. J., Green, N. H., Chapple, C. R., & MacNeil, S. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149971 · Cited by 22
Material Challenges and Opportunities in 3D Printing for Hip Implant Applications
Okolie, O., Stachurek, I., Kandasubramanian, B., & Njuguna, J. (2022) · Recent Progress in Materials · doi:10.21926/rpm.2201004 · Cited by 21
Roman, S., Mangır, N., Hympánová, L., Chapple, C., Deprest, J., & MacNeil, S. (2018) · Neurourology and Urodynamics · doi:10.1002/nau.23823 · Cited by 19
Nanostructured Polymer Biocomposites: Pharmaceutical Applications
Sagadevan, S., Fareen, A., Hoque, M. E., Chowdhury, Z. Z., Johan, M. R., Rafique, R. F., Aziz, F. H. A., & Lett, J. A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816771-7.00012-0 · Cited by 20
Mardina, Z., Venezuela, J., Maher, C., Shi, Z., Dargusch, M. S., & Atrens, A. (2022) · Biomaterials Science · doi:10.1039/d2bm00179a · Cited by 19
Enhanced cellular compatibility of chitosan/collagen multilayers LBL modified nanofibrous mats
Dai, F., Yu, J. X., Yuan, M., Deng, Z., Wang, Y., Fan, Y., Deng, H., & Cheng, Y. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.109717 · Cited by 17
Tomaszewska, A., Lubowiecka, I., & Szymczak, C. (2018) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34232 · Cited by 16
A preliminary study on the optimal choice of an implant and its orientation in ventral hernia repair
Lubowiecka, I., Szepietowska, K., Szymczak, C., & Tomaszewska, A. (2016) · Journal of Theoretical and Applied Mechanics/Mechanika Teoretyczna i Stosowana · doi:10.15632/jtam-pl.54.2.411 · Cited by 15
Polymeric Biomaterials in Clinical Practice
Marjanovic-Balaban, Z. R., & Jelić, D. (2017) · Springer eBooks · doi:10.1007/978-3-319-68025-5_4 · Cited by 13
A reliable and replicable test protocol for the mechanical evaluation of synthetic meshes
Civilini, V., Giacalone, V., Audenino, A. L., & Terzini, M. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.105987 · Cited by 12
Mechanical behaviour of knit synthetic mesh used in hernia surgery
Tomaszewska, A. (2016) · PubMed · doi:10.5277/abb-00185-2014-03 · Cited by 12
Bigozzi, M. A., Provenzano, S., Maeda, F. L., Palma, P. C. R., & Riccetto, C. (2015) · Neurourology and Urodynamics · doi:10.1002/nau.22890 · Cited by 11
Cristofari, F., Piotrowski, B., & Pesci, R. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.05.021 · Cited by 11
Liu, P., Shao, H. X., Chen, N., Cheng, N.-L., Jiang, J., & Jiang, J. (2018) · Fibres and Textiles in Eastern Europe · doi:10.5604/01.3001.0011.5743 · Cited by 11
Lu, X., Harman, M. K., Heniford, B. T., Augenstein, V. A., McIver, B., & Bridges, W. (2022) · Surgical Endoscopy · doi:10.1007/s00464-021-08882-4 · Cited by 10
Todros, S., Pachera, P., Pavan, P. G., & NATALI, A. N. (2017) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-017-0337-y · Cited by 10
Paul, K., Darzi, S., O’Connell, C. D., Hennes, D. M. Z. B., Rosamilia, A., Gargett, C. E., Werkmeister, J. A., & Mukherjee, S. (2024) · Advanced Science · doi:10.1002/advs.202405004 · Cited by 10
Khalifa, A., Isali, I., Celik, H., Mastran, M., McClellan, P. E., Gillespie, C. M., Shankar, S., MacLennan, G. T., Anderson, J. M., Schumacher, F. R., et al. (2022) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35120 · Cited by 8
Gai, K., Ren, X., Chen, J., Zhou, X., Wan, Q., Wang, Q., & Li, Y. (2022) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.2c03446 · Cited by 8
Combined numerical and experimental approach to determine numerical model of abdominal scaffold
Tomaszewska, A., & Reznikov, D. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.2005788 · Cited by 7
Wekwejt, M., Etmańska, D., Halman, A., Pałubicka, A., Świeczko‐Żurek, B., & Gajowiec, G. (2020) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34603 · Cited by 7
A review of ventral hernia biomechanics
Joppin, V., Masson, C., Bendahan, D., & Bège, T. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.107159 · Cited by 6
Simon, D., Andrews, S., Robinson‐Zeigler, R., Valdes, T., & Woods, T. O. (2017) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33898 · Cited by 6
Asayesh, A., & Yousefi, S. (2021) · Journal of the Textile Institute · doi:10.1080/00405000.2021.1883908 · Cited by 6
Adamo, F., Farina, M., Thekkedath, U. R., Grattoni, A., & Sesana, R. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.03.023 · Cited by 6
Liu, L., & Webster, T. J. (2017) · Springer eBooks · doi:10.1007/978-3-319-73664-8_2 · Cited by 5
Holzheimer, R. G. (2022) · Journal of Surgery · doi:10.29011/2575-9760.001549 · Cited by 4
Jain, T., Isayeva, I. S., & Simon, D. (2025) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37970 · Cited by 3
Fabricating a Low-Cost, Microscopy-Compatible Mechanical Testing Device
Mehta, S., Santos, D. R. D., Sridhar, S., Aguayo, V. C., Meraz, C. A., Mikos, M., & Grande-Allen, K. J. (2021) · Experimental Techniques · doi:10.1007/s40799-021-00513-w · Cited by 3
He, W., Shen, F., Xu, Z., Pei, B., Xie, H., & Li, X. (2023) · IRBM · doi:10.1016/j.irbm.2023.100777 · Cited by 3
Self-citationThe Development of Equipment to Measure Mesh Erosion of Soft Tissue
Schmidt, A., O’Brien, G., & Taylor, D. M. (2021) · Materials · doi:10.3390/ma14040941 · Cited by 3
Stiffness change of abdominal prosthesis Optomesh™ under cyclic loading
Tomaszewska, A., Szinvai, S., & Żerdzicki, K. (2019) · AIP conference proceedings · doi:10.1063/1.5091919 · Cited by 1
Serrano‐Aroca, Á., Cano-Vicent, A., Tuñón‐Molina, A., & Pous‐Serrano, S. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e24237 · Cited by 1
Analysis of the stress relaxation of synthetic surgical meshes in view of loading direction
Asayesh, A., & Yousefi, S. (2021) · Journal of the Textile Institute · doi:10.1080/00405000.2021.1940036 · Cited by 1
Tomaszewska, A., Lubowiecka, I., & Szymczak, C. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-97286-2_5 · Cited by 1
Kearney, R., Wagg, A., Bower, W., Chapple, C., Khullar, V., Robinson, D., Taithongchai, A., Hobson, P. T., Wein, A., & Abrams, P. (2026) · Neurourology and Urodynamics · doi:10.1002/nau.70272 · Cited by 1
“When undergoing cyclical testing, the stress/strain curves for PP show a rightward shift of the hysteresis loop, indicating permanent elongation of the mesh and possible long‐term viscous creep [56].”
Age-related changes of the pelvic floor ligaments, a biomechanical study
Pereira, F. B. D. R. (2015) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/1q9x-ps81
Cavallo, M. C., Callea, G., & Tarricone, R. (2019) · Springer eBooks · doi:10.1007/978-3-030-02426-0_9
Ai, W., Liu, X., You, S., Liu, F., Yu, Z., Tao, L., & Liu, H. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/562/1/012057
Research of strain fields of aponeurotic tissue at implantation of knitted polymeric meshes
Васильевич, С. С., & Staroverov, O. A. (2019) · Procedia Structural Integrity · doi:10.1016/j.prostr.2019.08.154
Przydacz, M., Adli, O. E. Y., Mahfouz, W. I., Loutochin, O., Bégin, L. R., & Corcos, J. (2017) · Editor-in-Chief s Voice List of Authors is an Important Element in a Scientific Publication · doi:10.5173/ceju.2017.1189
Surgery for pelvic organ prolapse: the quest to reduce failure rates
Wong, V. (2018) · The Sydney eScholarship Repository (The University of Sydney)
Self-citationSynthesis and characterization of substrates for grafting polymers used in medical plastics
Johnston, M., Sobhi, H. F., & Hajjar, A. (2020) · Chemical Data Collections · doi:10.1016/j.cdc.2020.100621
EXPERIMENTAL STUDIES OF MECHANICAL PROPERTIES OF IMPLANTS FOR PLASTY OF HERNIAL DEFECTS
(2019) · PNRPU Mechanics Bulletin · doi:10.15593/perm.mech/2019.2.14
Use of polypropylene mesh in orthopedic surgery – literature review and report of three cases
Medina, G., Mendes, C. L. N., Schor, B., Bitar, A. C., & Castropil, W. (2022) · Colloquium health and education · doi:10.37497/colloquium.v2i1.40
Xia, Y., Li, S., Yang, L., He, L., Liu, Y., Hu, Y., Liu, J., Wang, Y., Fan, H., Jiang, X., et al. (2026) · MedComm – Biomaterials and Applications · doi:10.1002/mba2.70042
Shen, Z., Li, Y., Chen, X., Tuo, D., Li, Y., Tang, M., Wang, S., Xiao, B., Wang, J., Wang, G., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.27.728119
Zhai, W., Guo, W., Wang, A., Huang, B., Tian, Y., Zhang, H., Zhu, X., Song, W., & Ren, L. (2026) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2026.153060
Sun, X.-B., Zou, C., Li‐Ling, J., & Xie, H. (2026) · Biofabrication · doi:10.1088/1758-5090/ae7bc7
Biomechanical Behavior of an Aged Synthetic Hernia Mesh Under a Cough-Simulating Protocol
Doneva, M., & Pashkouleva, D. (2026) · Materials · doi:10.3390/ma19163368
Cyclic tensile behavior of warp-knitted surgical meshes in view of loading direction
Ebrahimi, F., & Asayesh, A. (2026) · Mechanics of Time-Dependent Materials · doi:10.1007/s11043-026-09925-w
Metadata
- Authors
- Li, X., Kruger, J. A., Jor, J. W. Y., Wong, V., Dietz, H. P., Nash, M. P., & Nielsen, P. M. F.
- Affiliations
- University of Auckland (NZ)
- The University of Sydney (AU)
- Corresponding author
- Nielsen, Poul M.F.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2014-09
- Volume
- 37
- Pages
- 48-55
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2017096048
- Cited by
- 68
- References
- 30
- Citations by year
- 2026: 7 · 2025: 2 · 2024: 2 · 2023: 3 · 2022: 9 · 2021: 6 · 2020: 3 · 2019: 7 · 2018: 9 · 2017: 9 · 2016: 6 · 2015: 5
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (publishedVersion)
- PubMed (publishedVersion)
- ResearchSpace (University of Auckland) (submittedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Hernia repair and management
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- Prolene mesh, hernia repair, pelvic organ prolapse, anisotropy, creep, cyclic loading, viscoelasticity, permanent deformation, mesh erosion, postoperative complications
- MeSH terms
- Elasticity, Materials Testing, Polypropylenes, Surgical Mesh, Viscosity, Anisotropy, Mechanical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review