Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record.

Monitoring the penetration process of single microneedles with varying tip diameters

Open access
Römgens, A.M., Bader, D.L., Bouwstra, J.A., Baaijens, F.P.T., Oomens, C.W.J.·2014·Journal of the Mechanical Behavior of Biomedical Materials

Abstract

Microneedles represent promising tools for delivery of drugs to the skin. However, before these microneedles can be used in clinical practice, it is essential to understand the process of skin penetration by these microneedles. The present study was designed to monitor both penetration depth and force of single solid microneedles with various tip diameters ranging from 5 to 37µm to provide insight into the penetration process into the skin of these sharp microneedles. To determine the microneedle penetration depth, single microneedles were inserted in human ex vivo skin while monitoring the surface of the skin. Simultaneously, the force on the microneedles was measured. The average penetration depth at 1.5mm displacement was similar for all tip diameters. However, the process of penetration depth was significantly different for the various microneedles. Microneedles with a tip diameter of 5µm were smoothly inserted into the skin, while the penetration depth of microneedles with a larger tip diameter suddenly increased after initial superficial penetration. In addition, the force at insertion (defined as the force at a sudden decrease in measured force) linearly increased with tip diameter ranging from 20 to 167mN. The force drop at insertion was associated with a measured penetration depth of approximately 160μm for all tip diameters, suggesting that the drop in force was due to the penetration of a deeper skin layer. This study showed that sharp microneedles are essential to insert microneedles in a well-controlled way to a desired depth.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jmbbm.2014.09.015

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 195

Metadata

Authors
Römgens, A. M., Bader, D. L., Bouwstra, J. A., Baaijens, F. P. T., & Oomens, C. W. J.
Venue
Journal of the Mechanical Behavior of Biomedical Materials
Publisher
Elsevier BV
Published
2014-12
Volume
40
Pages
397-405
ISSN
1751-6161 (ISSN-L)
OpenAlex
W2041250960
Cited by
195
References
0
FWCI
3.95
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Monitoring the penetration process of single microneedles with varying tip diameters. https://app.cochat.ai/papers/10.1016/j.jmbbm.2014.09.015
The paper
Römgens, A. M., Bader, D. L., Bouwstra, J. A., Baaijens, F. P. T., & Oomens, C. W. J. (2014). Monitoring the penetration process of single microneedles with varying tip diameters. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2014.09.015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.