Cited by 94Elasticity and Material ModelingCorneal surgery and disordersCorneal Surgery and Treatments

Biomechanical model of the human cornea: Considering shear stiffness and regional variation of collagen anisotropy and density

Whitford, Charles, Studer, Harald, Boote, Craig, Meek, Keith M., Elsheikh, Ahmed·2015·Journal of the Mechanical Behavior of Biomedical Materials

Abstract

A numerical model based on continuum mechanics theory has been developed which represents the 3D anisotropic behaviour of the corneal stroma. Experimental data has been gathered from a number of previous studies to provide the basis and calibration parameters for the numerical modelling. The resulting model introduces numerical representation of collagen fibril density and its related regional variation, interlamellar cohesion and age-related stiffening in an anisotropic model of the human cornea. Further, the model incorporates previous modelling developments including representation of lamellae anisotropy and stiffness of the underlying matrix. Wide angle X-ray scattering has provided measured data which quantifies relative fibril anisotropy in the 2D domain. Accurate numerical description of material response to deformation is essential to providing representative simulations of corneal behaviour. Representing experimentally obtained 2D anisotropy and regional density variation in the 3D domain is an essential component of this accuracy. The constitutive model was incorporated into finite element analysis. Combining with inverse analysis, the model was calibrated to an extensive experimental database of ex vivo corneal inflation tests and ex vivo corneal shear tests. This model represents stiffness of the underlying matrix which is 2-3 orders of magnitude than the mechanical response representing the collagen fibrils in the lamellae. The presented model, along with its age…

Integrity signals

Registry

Crossref · 10.1016/j.jmbbm.2014.11.006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The lamellar structure acts like plywood, resisting fracture propagation, but bends and returns to its original position.

    “In addition, the lamellar structure acts rather like plywood, which resists fracture propagation, but bends and returns to its original position [11] (Fig. 4).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Whitford, C., Studer, H., Boote, C., Meek, K. M., & Elsheikh, A.
Affiliations
  • University of Liverpool (GB)
  • Cardiff University (GB)
  • Moorfields Eye Hospital NHS Foundation Trust (GB)
Corresponding author
Whitford, Charles
Venue
Journal of the Mechanical Behavior of Biomedical Materials
Publisher
Elsevier BV
Published
2015-02
Volume
42
Pages
76-87
ISSN
1751-6161 (ISSN-L)
OpenAlex
W1984355924
Cited by
94
References
1
Citations by year
2026: 3 · 2025: 7 · 2024: 11 · 2023: 9 · 2022: 9 · 2021: 5 · 2020: 9 · 2019: 10 · 2018: 9 · 2017: 10 · 2016: 5 · 2015: 7
FWCI
3.58
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (publishedVersion)
  • PubMed (publishedVersion)
  • ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
Funders
  • National Institute for Health and Care Research (HTD 539)
  • Medical Research Council (MR/K000837/1)
  • Engineering and Physical Sciences Research Council (EP/H052046/1)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
Keywords
human cornea, corneal biomechanics, corneal stroma, shear stiffness, regional variation, constitutive modeling, wide-angle X-ray scattering, inverse analysis, finite element analysis, refractive surgery planning
MeSH terms
Biomechanical Phenomena, Collagen, Cornea, Corneal Stroma, Humans, Models, Biological, Anisotropy, Finite Element Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review