Biomechanical model of the human cornea: Considering shear stiffness and regional variation of collagen anisotropy and density
Abstract
A numerical model based on continuum mechanics theory has been developed which represents the 3D anisotropic behaviour of the corneal stroma. Experimental data has been gathered from a number of previous studies to provide the basis and calibration parameters for the numerical modelling. The resulting model introduces numerical representation of collagen fibril density and its related regional variation, interlamellar cohesion and age-related stiffening in an anisotropic model of the human cornea. Further, the model incorporates previous modelling developments including representation of lamellae anisotropy and stiffness of the underlying matrix. Wide angle X-ray scattering has provided measured data which quantifies relative fibril anisotropy in the 2D domain. Accurate numerical description of material response to deformation is essential to providing representative simulations of corneal behaviour. Representing experimentally obtained 2D anisotropy and regional density variation in the 3D domain is an essential component of this accuracy. The constitutive model was incorporated into finite element analysis. Combining with inverse analysis, the model was calibrated to an extensive experimental database of ex vivo corneal inflation tests and ex vivo corneal shear tests. This model represents stiffness of the underlying matrix which is 2-3 orders of magnitude than the mechanical response representing the collagen fibrils in the lamellae. The presented model, along with its age…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The lamellar structure acts like plywood, resisting fracture propagation, but bends and returns to its original position.
“In addition, the lamellar structure acts rather like plywood, which resists fracture propagation, but bends and returns to its original position [11] (Fig. 4).”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [11]
Cites
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M. (2004) · Structure · doi:10.1016/j.str.2004.01.002 · Cited by 233 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Structural control of corneal transparency, refractive power and dynamics
Meek, K. M., Knupp, C., Lewis, P. N., Morgan, S. R., & Hayes, S. (2025) · Eye · doi:10.1038/s41433-024-02969-7 · Cited by 45 · see citing works
Self-citation
- Authors
- Whitford, C., Studer, H., Boote, C., Meek, K. M., & Elsheikh, A.
- Affiliations
- University of Liverpool (GB)
- Cardiff University (GB)
- Moorfields Eye Hospital NHS Foundation Trust (GB)
- Corresponding author
- Whitford, Charles
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 42
- Pages
- 76-87
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W1984355924
- Cited by
- 94
- References
- 1
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 11 · 2023: 9 · 2022: 9 · 2021: 5 · 2020: 9 · 2019: 10 · 2018: 9 · 2017: 10 · 2016: 5 · 2015: 7
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (publishedVersion)
- PubMed (publishedVersion)
- ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
- Funders
- National Institute for Health and Care Research (HTD 539)
- Medical Research Council (MR/K000837/1)
- Engineering and Physical Sciences Research Council (EP/H052046/1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
- Keywords
- human cornea, corneal biomechanics, corneal stroma, shear stiffness, regional variation, constitutive modeling, wide-angle X-ray scattering, inverse analysis, finite element analysis, refractive surgery planning
- MeSH terms
- Biomechanical Phenomena, Collagen, Cornea, Corneal Stroma, Humans, Models, Biological, Anisotropy, Finite Element Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review