Quantitative diagnosis of breast tumors by characterization of viscoelastic behavior of healthy breast tissue
Abstract
The main objective of the present study is to propose a model for characterizing the viscoelastic behavior of the healthy breast tissue. The study population consisted of 60 healthy regions of the breast tissue belonged to 9 female cases. To accomplish this, the attending cases were examined by a robot-assisted device and the mechanical stress resulted from an applied compressive strain was measured. Correlation between the experimental stress and the strain data identifies the breast tissue mechanical behavior. The tissue behavior was modeled by a five-element Maxwell-Wiechert model called model E. The model was personalized for every attending case via its coefficients based on a personalized diagnosis idea. The model performance was assessed by measuring the Mean Squared Error (MSE) and the match percentage of the model to the experimental data. Moreover, the model performance was compared with three common spring-dashpot models included the Maxwell model, the Burgers model and Standard Linear Solid model. Results affirmed that model E had the best data match in the whole mechanical loading and the MSE was considerably reduced. Subsequently model E was implemented for the tumor-included regions among the population study. Results showed that with a high match percentage, coefficients had significant deviations from the corresponding healthy regions' values for every individual. Consequently, personalized model E can be used for the healthy tissue characterization and tumor detection.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Artificial tactile sensing has also been used for assessment of liver, brain, and submucosal tumors.
“Artificial tactile sensing has also been used for other applications including assessment of liver, brain, and submucosal tumors [45].”
From The rise of artificial intelligence in healthcare applications (2020) · cites this paper as [45]
Cites
The Path to Personalized Medicine
Hamburg, M. A., & Collins, F. S. (2010) · New England Journal of Medicine · doi:10.1056/nejmp1006304 · Cited by 1,970 · see citing works
Findley, W. N., Lai, J. S., Onaran, K., & Christensen, R. M. (1977) · Journal of Applied Mechanics · doi:10.1115/1.3424077 · Cited by 679 · see citing works
Gutierrez-Lemini, D. (2013) · Springer eBooks · doi:10.1007/978-1-4614-8139-3 · Cited by 426 · see citing works
Human tactile perception as a standard for artificial tactile sensing—a review
Dargahi, J., & Najarian, S. (2004) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.3 · Cited by 373 · see citing works
Synthetic and Bio-Artificial Tactile Sensing: A Review
Lucarotti, C., Oddo, C. M., Vitiello, N., & Carrozza, M. C. (2013) · Sensors · doi:10.3390/s130201435 · Cited by 147 · see citing works
A Nonlinear Model of Passive Muscle Viscosity
Meyer, G. A., McCulloch, A. D., & Lieber, R. L. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004993 · Cited by 78 · see citing works
Personalized therapy for breast cancer
Abreu, F. B. D., Schwartz, G. N., Wells, W. A., & Tsongalis, G. J. (2014) · Clinical Genetics · doi:10.1111/cge.12381 · Cited by 74 · see citing works
Viscoelastic material models in peridynamics
Weckner, O., & Mohamed, N. A. N. (2013) · Applied Mathematics and Computation · doi:10.1016/j.amc.2012.11.090 · Cited by 73 · see citing works
Design and modeling of an endoscopic piezoelectric tactile sensor
Sedaghati, R., Dargahi, J., & Singh, H. (2005) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2005.03.029 · Cited by 67 · see citing works
Personalized medicine: Present and future of breast cancer management
Sabatier, R., Gonçalvès, A., & Bertucci, F. (2014) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2014.03.002 · Cited by 62 · see citing works
A Kelvin-Voight Fractional Derivative Model for Viscoelastic Characterization of Liver Tissue
Taylor, L. S., Lerner, A. L., Rubens, D. J., & Parker, K. J. (2002) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2002-32605 · Cited by 41 · see citing works
Hosseini, S. M., Kashani, S. M. T., Najarian, S., Panahi, F., Naeini, S. M. M., & Mojra, A. (2009) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.291 · Cited by 29 · see citing works
Self-citationMojra, A., Najarian, S., Kashani, S. M. T., Panahi, F., & Yaghmaei, M. (2011) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.396 · Cited by 26 · see citing works
Self-citationA Generalized Maxwell Model for Creep Behavior of Artery Opening Angle
Zhang, W., Guo, X., & Kassab, G. S. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2979853 · Cited by 25 · see citing works
Roke, C., Melhuish, C., Pipe, T., Drury, D., & Chorley, C. (2012) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2012.05.002 · Cited by 24 · see citing works
Non-invasive Measurement of Biomechanical Properties of in vivo Soft Tissues
Han, L., Burcher, M., & Noble, J. A. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45786-0_26 · Cited by 19 · see citing works
A novel robotic tactile mass detector with application in clinical breast examination
Mojra, A., Najarian, S., Kashani, S. M. T., Panahi, F., & Tehrani, M. A. (2011) · Minimally Invasive Therapy & Allied Technologies · doi:10.3109/13645706.2011.602087 · Cited by 16 · see citing works
Self-citationAnssari-Benam, A., Bucchi, A., & Bader, D. L. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.07.015 · Cited by 12 · see citing works
Mojra, A., Najarian, S., Kashani, S. M. T., & Panahi, F. (2011) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.629275 · Cited by 11 · see citing works
Self-citationScanlan, P., Hammer, S. J., Good, D. W., Phipps, S., Stewart, G. D., McNeill, S. A., Shu, W., & Reuben, R. L. (2015) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2015.06.023 · Cited by 9 · see citing works
Kim, Y., Ahn, B., Na, Y., Shin, T. Y., Rha, K. H., & Kim, J. (2014) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-013-0321-6 · Cited by 7 · see citing works
An, B., & Kim, J. W. (2006) · Key engineering materials · doi:10.4028/www.scientific.net/kem.326-328.781 · Cited by 5 · see citing works
Personalized/Precision Medicine
Simon, R. (2016) · Wiley StatsRef: Statistics Reference Online · doi:10.1002/9781118445112.stat07836 · Cited by 2 · see citing works
Flagged first, then by citations
1 of the 24 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
The rise of artificial intelligence in healthcare applications
Bohr, A., & Memarzadeh, K. (2020) · Artificial Intelligence in Healthcare · doi:10.1016/b978-0-12-818438-7.00002-2 · Cited by 1,636 · see citing works
Viscoelastic Cell Microenvironment: Hydrogel‐Based Strategy for Recapitulating Dynamic ECM Mechanics
Ma, Y., Han, T., Yang, Q., Wang, J., Feng, B., Jia, Y., Zhao, W., & Xu, F. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202100848 · Cited by 211 · see citing works
Why Are Viscosity and Nonlinearity Bound to Make an Impact in Clinical Elastographic Diagnosis?
Rus, G., Faris, I. H., Torres, J., Callejas, A. M., & Rodríguez, J. M. M. (2020) · Sensors · doi:10.3390/s20082379 · Cited by 81 · see citing works
Hydrogel‐based composites: Unlimited platforms for biosensors and diagnostics
Wang, Z., Liu, Y., Wang, Z., Huang, X. B., & Huang, W. (2021) · Open Research (University of Surrey) · doi:10.1002/viw.20200165 · Cited by 68 · see citing works
Characterizing viscoelastic properties of breast cancer tissue in a mouse model using indentation
Qiu, S., Zhao, X., Chen, J., Zeng, J., Chen, S., Chen, L., Meng, Y., Liu, B., Shan, H., Gao, M., et al. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.01.007 · Cited by 39 · see citing works
Ezenwafor, T. C., Anye, V. C., Madukwe, J., Amin, S., Obayemi, J. D., Odusanya, O. S., & Soboyejo, W. O. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.01.011 · Cited by 18 · see citing works
i-Rheo-optical assay: Measuring the viscoelastic properties of multicellular spheroids
Ferraro, R., Guido, S., Caserta, S., & Tassieri, M. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101066 · Cited by 12 · see citing works
Ramazanilar, M., & Mojra, A. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110222 · Cited by 12 · see citing works
Self-citationYang, Z., Wu, P., Liu, W., & Fang, H. (2020) · International Journal of Applied Mechanics · doi:10.1142/s1758825120500623 · Cited by 9 · see citing works
Yang, Z., Wu, P., & Liu, W. (2020) · Archive of Applied Mechanics · doi:10.1007/s00419-020-01677-4 · Cited by 9 · see citing works
An Equal-Biaxial Test Device for Large Deformation in Cruciform Specimens
Ru, M., Lei, X., Liu, X., & Wei, Y. (2022) · Experimental Mechanics · doi:10.1007/s11340-021-00810-w · Cited by 8 · see citing works
Biomechanical Modelling of Porcine Kidney
Mishra, A., & Cleveland, R. O. (2024) · Bioengineering · doi:10.3390/bioengineering11060537 · Cited by 6 · see citing works
“Application Of AI And Blockchain In Healthcare Industry” – A Review
Biswas, I., & Singh, D. R. K. (2024) · Journal Of Advanced Zoology · doi:10.53555/jaz.v45i2.3983 · Cited by 5 · see citing works
Unified rheological modeling using fractal calculus for soft biological matter
Gopalakrishnan, V. K., Pramanik, R., & Arockiarajan, A. (2025) · Materials & Design · doi:10.1016/j.matdes.2025.114572 · Cited by 4 · see citing works
Chen, H., Huang, Y., Yin, S., Li, C., & Zhang, F. (2025) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2025.189463 · Cited by 4 · see citing works
K., A. V. G., Gogoi, G., Kachappilly, M. C., Rangarajan, A., & Pandya, H. J. (2023) · Journal of Biological Engineering · doi:10.1186/s13036-023-00388-y · Cited by 2 · see citing works
Correlation between stress drop and applied strain as a biomarker for tumor detection
Yang, Y., Guo, S., & Hao, Z. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.07.023 · Cited by 2 · see citing works
Yusuf, N. K., Salavati, H., van Ramshorst, G. H., Sarıbal, D., Debbaut, C., & Ceelen, W. P. (2025) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-025-02019-5 · Cited by 1 · see citing works
An in Vivo Study on Evaluation of Early Relaxation Time in Breast Tissue
Baghban, M. H. M., & Mojra, A. (2017) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme.2017.8430282
Self-citationChen, J., Zhou, B., Qiu, S., Ma, S., Lee, C., Aggarwal, A., Zeng, J., Gao, M., Feng, Y., Li, D., et al. (2018) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4041502
Vishnu, G. K. A., Gogoi, G., Kachappilly, M. C., Rangarajan, A., & Pandya, H. J. (2023) · Figshare · doi:10.6084/m9.figshare.24558163
- Authors
- Madani, N., & Mojra, A.
- Affiliations
- K. N. Toosi University of Technology (IR)
- Corresponding author
- Mojra, A.
- ORCID
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2017-04
- Volume
- 68
- Pages
- 180-187
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2585605954
- Cited by
- 21
- References
- 24
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 3 · 2022: 1 · 2021: 2 · 2020: 4 · 2019: 1 · 2018: 3 · 2017: 1
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- breast tumors, viscoelastic behavior, compressive strain, spring-dashpot model, tumor detection
- MeSH terms
- Adult, Breast, Breast Neoplasms, Elasticity, Female, Humans, Middle Aged, Models, Biological, Robotics, Stress, Mechanical, Viscosity, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review