CoChat

Multimodal assessment of the skin biomechanical properties during wound healing and hyaluronic acid response

Open access
Bouffandeau, Arthur, Poisbleau, David, Ouidja, Mohand Ou Idir, Karasinski, Patrick, Papy, Dulce, Flouzat-Lachaniette, Charles-Henri, Bosc, Romain, Hersant, Barbara, Meningaud, Jean-Paul, Haiat, Guillaume · 2026 · Journal of the Mechanical Behavior of Biomedical Materials

The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index; none of the 66 sources its claims cite is checked for support yet.

Abstract

Various methods such as elastography or mechanical testing have been developed to quantify the mechanical properties of soft tissues, which are related to the tissue local pathophysiological conditions. This study is the first one to investigate the in vivo performances of the Impact-Based Analysis Method (IBAM) to characterize the biomechanical behavior of skin during physiological mechanisms. A murine model (12 Sprague-Dawley rats) was considered and various measurements of skin mechanical properties were conducted on different regions of interest over a 3-week period. The effects of wound healing after full-thickness excisional wound and an intradermal hyaluronic acid (HA) injection were monitored using IBAM, as well as two commercially available devices: Cutometer® and MyotonPro®. The indicators Δt (from IBAM), R0 and R5 (from Cutometer®) vary significantly as a function of wound healing time, which corresponds to a stiffening of healing tissue compared to healthy tissue. The indicator Δt and S (from MyotonPro®) are significantly different when HA was injected compared to healthy tissue, which also corresponds to less stiff tissue. Additionally, both IBAM and Cutometer® detect significant biomechanical variations in superficial soft tissue related to tissue growth in all measurement regions. This first in vivo use of IBAM shows that IBAM could assess significant variations related to wound healing or regeneration mechanisms following HA injection. This study paves the way for the development of a simple, low-cost and objective device. Future clinical studies or other animal models should be carried out to confirm these results.

Overview

CoChat Summary

TL;DR

This first in vivo study of IBAM used 12 Sprague-Dawley rats to compare IBAM, Cutometer, and MyotonPro for skin biomechanics during wound healing and after intradermal hyaluronic acid injection over 3 weeks. IBAM detected significant changes in both wound healing and HA response, while Cutometer detected wound healing/age effects and MyotonPro detected HA effects.

Key findings

  • Wound healing: IBAM’s Δt and Cutometer’s R0 and R5 varied significantly with healing time, corresponding to stiffening of healing tissue versus healthy tissue. R5 was significantly higher in the wound-healing group than control throughout D13–D17; Δt was lower in wound healing than control at D7 and D15 by hypothesis testing and at D4, D7, and D15 by confidence interval.
  • Hyaluronic acid: IBAM’s Δt and MyotonPro’s S were significantly different after HA injection versus healthy tissue, corresponding to less stiff tissue. S was lower for HA-0.5 mL versus control after D4 by both HT and CI; Δt was higher for HA-0.5 mL versus control between D4 and D15 by CI, confirmed at D7 and D15 by HT.
  • IBAM and Cutometer detected significant biomechanical variations related to tissue growth in all measurement regions; MyotonPro’s S did not show a significant time effect despite small-to-large effect sizes.
  • Repeatability/reproducibility: lowest repeatability was S (3.2%) and Δt (3.5%); S had the best reproducibility (6.2%), while Cutometer R5 had the worst (13.2% repeatability, 28.0% reproducibility).

Methods

  • Twelve adult male Sprague-Dawley rats, 6 weeks old at start, were studied over D0, D4, D7, D13, D15, and D17; one rat was lost after D7. Five regions were measured: right upper back full-thickness excisional wound (10×10 mm), left upper back control, right lower back HA injection (0.50 mL for 6 rats or 0.25 mL for 6 rats), left lower back control, and median ventral control.
  • Three non-invasive techniques were used: IBAM (3-gram hammer with force sensor; 4 mm aluminum punch with 2 mm hemisphere; Δt from first two force peaks, averaged over five impacts with first-peak force 8–10 N), Cutometer (R0 and R5; 2 mm probe, 450 mbar, three 2 s aspiration/2 s relaxation cycles), and MyotonPro (S; five repetitions).
  • Analysis included z-score outlier detection (threshold 1.96), Shapiro-Wilk normality testing, Welch’s t-test or Wilcoxon rank-sum tests, one-way ANOVA or Kruskal-Wallis tests, comparisons versus D0, and comparisons between affected and control groups using hypothesis tests and 95% confidence intervals of the mean difference; significance was 5%, with effect sizes reported for non-significant tests.

Limitations

  • Stated: the murine model differs from human skin (murine skin thickness <25 µm versus human >1 mm; panniculus carnosus), so porcine models may be more satisfactory; rat wound healing is faster than human, measurement frequency and duration could be increased, blood/scab prevented Cutometer measurements at D4/D7 wound sites, less invasive wound models were suggested, and device parameters could be modified (MyotonPro L-shape probe; Cutometer 6/8 mm probes).
  • Stated: IBAM is still under development; punch geometry changed from 4 to 2 mm and to a half-sphere, and IBAM may primarily detect superficial changes and be less sensitive to medium- and long-term HA effects in the reticular dermis, so longer studies are needed.
  • Evident from the text: the cohort was small and male-only (12 rats, one lost after D7), follow-up was only 3 weeks, and no human validation was performed; literature cited in the paper expects HA effects to last 6–12 months, so the study period may be too short to capture them.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1016/j.jmbbm.2026.107451

Cites

76 of 76 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Schematic illustration of the experimental protocol. Location of the five sites ('wound healing', 'hyaluronic acid injection' and 3 'control') characterized by the three mechanical surface characterization techniques on different experimental days, noted 𝑫𝒊 .
Figure 1 Schematic illustration of the experimental protocol. Location of the five sites ('wound healing', 'hyaluronic acid injection' and 3 'control') characterized by the three mechanical surface characterization techniques on different experimental days, noted 𝑫𝒊 .CC-BY · From the PDF
Figure 2 Picture of the positioning of an anesthetized rat in the measurement support before shaving and identification of measurement site at first day of the protocol 𝑫𝟎 .
Figure 2 Picture of the positioning of an anesthetized rat in the measurement support before shaving and identification of measurement site at first day of the protocol 𝑫𝟎 .CC-BY · From the PDF
Figure 3 (A) Illustration of the experimental set-up of Impact-Based Analysis Method (IBAM). (B) Example of force signal obtained following hammer impact with 𝜟𝒕𝒊 = 4.47 ms and 𝑭𝒊,𝟏 = 9.1 N.
Figure 3 (A) Illustration of the experimental set-up of Impact-Based Analysis Method (IBAM). (B) Example of force signal obtained following hammer impact with 𝜟𝒕𝒊 = 4.47 ms and 𝑭𝒊,𝟏 = 9.1 N.CC-BY · From the PDF
Figure 4 (A) Illustration of Cutometer ® device with a 2 mm-diameter probe. (B) Example of tissue deformation during one cycle (aspiration / relaxation) with 𝑹𝟎 = 0.438 mm and 𝑹𝟓 = 𝑼𝒓 /𝑼𝒆 = 1.079.
Figure 4 (A) Illustration of Cutometer ® device with a 2 mm-diameter probe. (B) Example of tissue deformation during one cycle (aspiration / relaxation) with 𝑹𝟎 = 0.438 mm and 𝑹𝟓 = 𝑼𝒓 /𝑼𝒆 = 1.079.CC-BY · From the PDF
Figure 5 (A) Illustration of MyotonPro ® device. (B) Example of acceleration and displacement of the tissue response as function of time with 𝑺 = 𝒎𝒑 × 𝒂𝒎𝒂𝒙 /𝜟𝒍 = 297 N/m.
Figure 5 (A) Illustration of MyotonPro ® device. (B) Example of acceleration and displacement of the tissue response as function of time with 𝑺 = 𝒎𝒑 × 𝒂𝒎𝒂𝒙 /𝜟𝒍 = 297 N/m.CC-BY · From the PDF
Figure 6 Variation of the different indicators for wound healing and control sites for the different healing times: (A) 𝜟𝒕 obtained from IBAM, (B) 𝑺 obtained from MyotonPro, (C) 𝑹𝟎 and (D) 𝑹𝟓 obtained from Cutometer. The values for day 0 were measured prior to wound generation event. Each point corresponds to the mean ± standard deviation. The significant differences (p-value < 0.05) with respect to day 0 are indicated by significance brackets with * (respectively *) for values from 'wound healing' (respectively 'control') groups.
Figure 6 Variation of the different indicators for wound healing and control sites for the different healing times: (A) 𝜟𝒕 obtained from IBAM, (B) 𝑺 obtained from MyotonPro, (C) 𝑹𝟎 and (D) 𝑹𝟓 obtained from Cutometer. The values for day 0 were measured prior to wound generation event. Each point corresponds to the mean ± standard deviation. The significant differences (p-value < 0.05) with respect to day 0 are indicated by significance brackets with * (respectively *) for values from 'wound healing' (respectively 'control') groups.CC-BY · From the PDF
Figure 7 Variation of the mechanical parameters of intradermal hyaluronic acid injection (0.5 or 0.25 mL dose) and control sites on the lower back over time: (A) 𝜟𝒕 from IBAM, (B) 𝑺 from MyotonPro, (C) 𝑹𝟎 and (D) 𝑹𝟓 from Cutometer. The values for day 0 were measured prior to hyaluronic acid injection. Each point corresponds to the mean ± standard deviation. The significant differences (p-value < 0.05) with respect to day 0 are indicated by significance brackets with * (respectively * and *) for values from 'HA - 0.5 mL' (respectively 'HA - 0.25 mL' and 'control') groups.
Figure 7 Variation of the mechanical parameters of intradermal hyaluronic acid injection (0.5 or 0.25 mL dose) and control sites on the lower back over time: (A) 𝜟𝒕 from IBAM, (B) 𝑺 from MyotonPro, (C) 𝑹𝟎 and (D) 𝑹𝟓 from Cutometer. The values for day 0 were measured prior to hyaluronic acid injection. Each point corresponds to the mean ± standard deviation. The significant differences (p-value < 0.05) with respect to day 0 are indicated by significance brackets with * (respectively * and *) for values from 'HA - 0.5 mL' (respectively 'HA - 0.25 mL' and 'control') groups.CC-BY · From the PDF
Figure 8 Variation of the mechanical parameters of median ventral control site as a function of time: (A) 𝜟𝒕 from IBAM, (B) 𝑺 from MyotonPro, (C) 𝑹𝟎 and (D) 𝑹𝟓 from Cutometer. Each point corresponds to the mean ± standard deviation. The significant differences (p-value < 0.05) with respect to day 0 are indicated by significance brackets with *.
Figure 8 Variation of the mechanical parameters of median ventral control site as a function of time: (A) 𝜟𝒕 from IBAM, (B) 𝑺 from MyotonPro, (C) 𝑹𝟎 and (D) 𝑹𝟓 from Cutometer. Each point corresponds to the mean ± standard deviation. The significant differences (p-value < 0.05) with respect to day 0 are indicated by significance brackets with *.CC-BY · From the PDF

Verification

Claims the paper makes

0 Valid · 4 Not valid · 45 Not checked · 89 Own results and interpretations

55 more claims

Create a free account to see all 138 claims and to verify the 54 references still open.

See all claims — free account
  • It may state two separate claims as one. 31
  • Probably not a substantial claim. 57
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

4 of 4

Citations

Cites

Show all 76 references

Research works printed but not linked: 1

  1. Wallace HA, Basehore BM, Zito PM. Wound Healing Phases. 2023 Jun 12. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan -. PMID: 29262065.

Cited by

Still being checked.

Metadata

Authors
Bouffandeau, A., Poisbleau, D., Ouidja, M. O. I., Karasinski, P., Papy, D., Flouzat-Lachaniette, C.-H., Bosc, R., Hersant, B., Meningaud, J.-P., & Haiat, G.
Affiliations
  • Centre National de la Recherche Scientifique (FR)
  • Inserm (FR)
Venue
Journal of the Mechanical Behavior of Biomedical Materials
Publisher
Elsevier BV
Published
2026-08
Volume
180
Pages
107451
ISSN
  • 1878-0180 (ISSN-L)
  • 1751-6161
OpenAlex
W7155879648
Cited by
2
References
76
Citations by year
2026: 2
FWCI
4.51
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (submittedVersion)
  • HAL (submittedVersion, cc-by)
Funders
  • H2020 European Research Council (101147066)
  • Conseil National de la Recherche Scientifique
  • European Research Council
  • Horizon 2020
  • French National Research Agency (ANR-24-LCV2-0009)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
  • Health Sciences › Medicine › Surgery › Wound Healing and Treatments
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
Keywords
skin biomechanics, wound healing, hyaluronic acid injection, skin stiffness, Cutometer, MyotonPRO, full-thickness excisional wounds, tissue regeneration, multimodal assessment
MeSH terms
Animals, Biomechanical Phenomena, Hyaluronic Acid, Male, Materials Testing, Skin, Wound Healing, Rats, Sprague-Dawley, Rats, Mechanical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-26, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-26 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.