CoChat

Low Back Pain: Clinimetric Properties of the Trendelenburg Test, Active Straight Leg Raise Test, and Breathing Pattern During Active Straight Leg Raising

Roussel, Nathalie A., Nijs, Jo, Truijen, Steven, Smeuninx, Line, Stassijns, Gaetane · 2007 · Journal of Manipulative and Physiological Therapeutics
Cited by 105

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Classification of patients with low back pain (LBP) into subgroups is important as considerable variability exists in the LBP population. Clinical applicable, reliable, and valid tests to differentiate patients with LBP are therefore necessary. The purpose of this study is to examine the reliability, internal consistency, and clinical importance of 3 clinical tests that analyze motor control mechanisms of the lumbopelvic region in patients with nonspecific LBP. METHODS: Thirty-six patients with chronic nonspecific LBP volunteered for the study (cross-sectional design). The patients were examined by 2 assessors who were blinded to the results of each other. The following tests were performed: the Trendelenburg test, the active straight leg raise (ASLR) test, and the ASLR with visual inspection of the breathing pattern. RESULTS: The test-retest reliability coefficients (kappa) were greater than 0.75 for the Trendelenburg score and greater than 0.70 for the ASLR. The interobserver reliability coefficients were greater than 0.39 for the assessment of the breathing pattern during the ASLR. The Cronbach alpha coefficient for internal consistency of the Trendelenburg and ASLR tests was greater than .73. No significant associations were found between the outcome of the tests and self-reported pain severity or disability. CONCLUSIONS: These data provide evidence favoring the test-retest reliability of the Trendelenburg and ASLR tests in patients with LBP. The internal consistency of the outcome of these tests was high for both assessors, suggesting that these tests assess the same dimension. The interobserver reliability of the assessment of the breathing pattern was fair to moderate. Further research regarding the interobserver reliability, clinical importance, validity, and responsiveness of the Trendelenburg test, ASLR test, and breathing pattern during these tests is required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jmpt.2007.03.001

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

Metadata

Authors
Roussel, N. A., Nijs, J., Truijen, S., Smeuninx, L., & Stassijns, G.
Venue
Journal of Manipulative and Physiological Therapeutics
Publisher
Elsevier BV
Published
2007-05
Volume
30
Issue
4
Pages
270-278
ISSN
0161-4754 (ISSN-L)
OpenAlex
W1988483737
Cited by
105
References
12
FWCI
2.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.