A Systematic Review of Reliability and Validity Studies of Methods for Measuring Active andPassive Cervical Range of Motion
The DOI matches its Crossref record.
Abstract
OBJECTIVE: The purpose of this study was to systematically review the literature evaluating the reliability and validity of all available methods for measuring active and passive cervical range of motion (CROM). METHODS: Electronic databases (PubMed, MEDLINE, CINAHL, EMBASE, and AMED) were searched through OVID from their inception to January 2008. Articles were selected according to a priori defined criteria. Data were extracted regarding publication details, type of study, movements and device evaluated, subject and observer characteristics, and measurement protocol including blinding and statistical analysis methods. Quality assessment was undertaken using developed criteria to assess internal validity, external validity, and statistical methods. An estimate of the level of reliability and validity was calculated and used to categorize studies as good, moderate, or poor. RESULTS: A total of 56 articles fulfilled the selection criteria and were included in the review. Forty-six of these articles described 66 reliability studies and 21 described 21 concurrent criterion validity studies. Twelve different methods were evaluated. Although it was the intention of this review to conduct meta-analysis, this was deemed inappropriate due to studies being too heterogeneous. Most of the reliability and validity studies involved asymptomatic subjects measured by allied health professionals investigating active ROM. Devices that were deemed to have "good" reliability and validity were the CROM device, the Spin-T goniometer, and the single inclinometer. CONCLUSIONS: A considerable number of reliability and concurrent validity studies have been published for CROM. The CROM device has undergone most evaluation and has been shown to be clinimetrically sound. Further research with significantly improved methodology and reporting is warranted for all devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blanpied, P. R., Gross, A. R., Elliott, J. M., Devaney, L. L., Clewley, D., Walton, D. M., Sparks, C., & Robertson, E. K. (2017) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2017.0302 · Cited by 979
Duc, C., Salvia, P., Lubansu, A., Feipel, V., & Aminian, K. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.09.002 · Cited by 61
“The anatomy of the cervical spine and the “resulting coupled ovements” make the measurement of cervical range of motion hallenging [2].”
BackgroundWiangkham, T., Duda, J., Haque, M. S., Price, J., & Rushton, A. (2019) · PLOS ONE · doi:10.1371/journal.pone.0215803 · Cited by 22
Metadata
- Authors
- Williams, M. A., McCarthy, C. J., Chorti, A., Cooke, M. W., & Gates, S.
- Venue
- Journal of Manipulative and Physiological Therapeutics
- Publisher
- Elsevier BV
- Published
- 2010-02
- Volume
- 33
- Issue
- 2
- Pages
- 138-155
- ISSN
- 0161-4754 (ISSN-L)
- OpenAlex
- W2085759723
- Cited by
- 230
- References
- 0
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.