Cross polarization, radio frequency field homogeneity, and circuit balancing in high field solid state NMR probes
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, Paulson and colleagues [31] have shown that significant CP field mismatch in a double-tuned solenoid coil occurs when its electrical length becomes comparable to 1/4 of the 1 H wavelength, making the above argument irrelevant for the combination of high-field strengths and large sample volumes described in this manuscript.”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [31]
In the citing paper
“Although the resonator loop is too short for 1 H wavelength effects to be of significance, balancing equalizes the voltage at the ends of the 1 H coil L 0 and so reduces the probability of arcing [43,31,16].”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 14
- Stejskal, 1977, Magic-angle spinning and polarization transfer in proton-enhanced NMR, J. Magn. Reson., 28, 105
- Wu, 1993, Cross-polarization with high-speed magic-angle-spinning, J. Magn. Reson. A, 104, 154, 10.1006/jmra.1993.1203 · doi:10.1006/jmra.1993.1203
- Gan, 1990, Rotational resonance in a spin-lock field for solid-state NMR, Chem. Phys. Lett., 168, 304, 10.1016/0009-2614(90)85615-J · doi:10.1016/0009-2614(90)85615-j
- Ishii, 1995, C-13-H-1 Dipolar recoupling dynamics in C-13 multiple-pulse solid-state NMR, Chem. Phys. Lett., 246, 439, 10.1016/0009-2614(95)01136-5 · doi:10.1016/0009-2614(95)01136-5
- Campbell, 1995, Effect of Rf inhomogeneity upon quantitative solid-state NMR measurements, J. Magn. Reson. A, 112, 225, 10.1006/jmra.1995.1035 · doi:10.1006/jmra.1995.1035
- Idziak, 1982, Design and construction of a high homogeneity RF coil for solid-state multiple-pulse NMR, J. Magn. Reson., 50, 281
- Privalov, 1996, Coil design for large-volume high-B1 homogeneity for solid-state NMR applications, J. Magn. Reson. A, 123, 157, 10.1006/jmra.1996.0229 · doi:10.1006/jmra.1996.0229
- Larsen, 1995, Improving RF field homogeneity in solid-state MAS NMR using a loop-gap resonator, J. Magn. Reson. A, 115, 283, 10.1006/jmra.1995.1181 · DOI · Paper page
- Engelke, 2002, Electromagnetic wave compression and radio frequency homogeneity in NMR solenoidal coils: Computational approach, Concepts Magn. Reson., 15, 129, 10.1002/cmr.10029 · doi:10.1002/cmr.10029
- Metz, 1994, Ramped-amplitude cross-polarization in magic-angle-spinning NMR, J. Magn. Reson. A, 110, 219, 10.1006/jmra.1994.1208 · DOI · Paper page
- Stuhlman, 1932, The magnetic field of a solenoid oscillating at radio frequencies, Rev. Sci. Instrum., 3, 561, 10.1063/1.1748871 · DOI · Paper page
- Martin, 2003, Design of a triple resonance magic angle sample spinning probe for high field solid state nuclear magnetic resonance, Rev. Sci. Instrum., 74, 3045, 10.1063/1.1571951 · DOI · Paper page
- Maas, 1999, Magnetic field gradients in solid state magic angle spinning NMR, J. Magn. Reson., 141, 29, 10.1006/jmre.1999.1892 · doi:10.1006/jmre.1999.1892
- Doty, 1998, Magnetism in high-resolution NMR probe design. II: HR MAS, Concepts Magn. Reson., 10, 239, 10.1002/(SICI)1099-0534(1998)10:4<239::AID-CMR2>3.0.CO;2-Y · DOI
Cited by
Gor’kov, P. L., Chekmenev, E. Y., Li, C., Cotten, M., Buffy, J. J., Traaseth, N. J., Veglia, G., & Brey, W. W. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.11.008 · Cited by 213
NMR spectroscopy up to 35.2 T using a series-connected hybrid magnet
Gan, Z., Hung, I., Wang, X., Paulino, J., Wu, G., Litvak, I. M., Gor'kov, P. L., Brey, W. W., Lendi, P., Schiano, J. L., et al. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2017.08.007 · Cited by 202
Gopinath, T., Wang, S., Lee, J., Aihara, H., & Veglia, G. (2019) · Journal of Biomolecular NMR · doi:10.1007/s10858-019-00237-5 · Cited by 14
Metadata
- Authors
- Paulson, E. K., Martin, R. W., & Zilm, K. W.
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2004-12
- Volume
- 171
- Issue
- 2
- Pages
- 314-323
- ISSN
- 1090-7807
- Cited by
- 70
- References
- 0
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.