Using a cross-coil to reduce RF heating by an order of magnitude in triple-resonance multinuclear MAS at high fields
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A cross-coil probe design becomes more attractive at higher fields [9] and allows each coil to address its frequency-specific tasks, permitting substantial simplifications in the RF circuit.”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [9]
In the citing paper
“Since sample dielectric loss depends strongly on frequency [6,8,29,9], the vast majority of sample heating occurs from RF irradiation at the 1 H frequency.”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 19
- Martin, 2003, Design of a triple resonance MAS probe for high field solid-state NMR, Rev. Sci. Instrum., 74, 3045, 10.1063/1.1571951 · DOI · Paper page
- Doty, 1998, Magnetism in NMR probe design part II: HR MAS, Concept Magn. Reson., 10, 239, 10.1002/(SICI)1099-0534(1998)10:4<239::AID-CMR2>3.0.CO;2-Y · DOI
- Doty, 1999, Practical aspects of birdcage coils, J. Magn. Reson., 138, 144, 10.1006/jmre.1998.1703 · DOI
- Tropp, 2004, Image brightening in samples of high dielectric constant, J. Magn. Reson., 167, 12, 10.1016/j.jmr.2003.11.003 · DOI
- Weiland, 1996, Time domain electromagnetic field computation with finite difference methods, Int. J. Num. Mod., 9, 295, 10.1002/(SICI)1099-1204(199607)9:4<295::AID-JNM240>3.0.CO;2-8 · DOI · Paper page
- Doty, 1981, A multinuclear double-tuned probe for applications with solids or liquids utilizing lumped tuning elements, J. Magn. Reson., 43, 399
- Hardy, 1981, Split-ring resonator for use in magnetic resonance from 200–2000MHz, Rev. Sci. Instrum., 52, 213, 10.1063/1.1136574 · DOI
- F.D. Doty, Resonator sensitivity optimization in magnetic resonance and the development of a magic angle spinning probe for the NMR study of rare spin nuclei on catalytic surfaces, Ph.D Dissertation, University of South Carolina, Columbia, SC, 1983.
- Larsen, 1995, Improving RF field homogeneity in solid-state MAS NMR using a loop-gap resonator, J. Magn. Reson. A, 115, 283, 10.1006/jmra.1995.1181 · DOI · Paper page
- Stringer, 2005, Reduction of RF-induced sample heating with a scroll coil resonator structure for solid-state NMR probes, J. Magn. Reson., 173, 40, 10.1016/j.jmr.2004.11.015 · DOI · Paper page
- Grant, 2001, Analysis of multilayer RF micro-coils for NMR spectroscopy, IEEE Trans. Magn., 37, 2989, 10.1109/20.947051 · DOI
- Doty, 1999, Error-tolerant RF litz coils for NMR/MRI, J. Magn. Reson., 140, 17, 10.1006/jmre.1999.1828 · doi:10.1006/jmre.1999.1828
- F.D. Doty, Triple-Resonance Single-Coil Circuits for Solids NMR Probes. Presented at the 33rd Rocky Mountain Conference on Analytical Chemistry, Denver, 1991.
- Stringer, 1998, Methods for the analysis and design of a solid state nuclear magnetic resonance probe, Rev. Sci. Instrum., 69, 3384, 10.1063/1.1149104 · doi:10.1063/1.1149104
- Zhang, 1998, Double and triple resonance circuits for high-frequency probes, J. Magn. Reson., 132, 167, 10.1006/jmre.1998.1386 · DOI
- Sinha, 2005, SPINAL modulated decoupling in high field double- and triple-resonance solid-state NMR experiments on stationary samples, J. Magn. Reson., 177, 197, 10.1016/j.jmr.2005.07.008 · doi:10.1016/j.jmr.2005.07.008
- Paulson, 2004, Cross-polarization, radio-frequency field homogeneity, and circuit balancing in high-field solid-state NMR probes, J. Magn. Reson., 171, 314, 10.1016/j.jmr.2004.09.009 · DOI · Paper page
- Elbayed, 2005, Field modulation effects induced by sample spinning: application to high-resolution magic angle spinning NMR, J. Magn. Reson., 174, 2, 10.1016/j.jmr.2004.11.017 · DOI
- Tekely, 2001, Radial-field sidebands in MAS, J. Magn. Reson., 148, 135, 10.1006/jmre.2000.2215 · DOI
Cited by
Gor’kov, P. L., Chekmenev, E. Y., Li, C., Cotten, M., Buffy, J. J., Traaseth, N. J., Veglia, G., & Brey, W. W. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.11.008 · Cited by 213
NMR spectroscopy up to 35.2 T using a series-connected hybrid magnet
Gan, Z., Hung, I., Wang, X., Paulino, J., Wu, G., Litvak, I. M., Gor'kov, P. L., Brey, W. W., Lendi, P., Schiano, J. L., et al. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2017.08.007 · Cited by 202
Metadata
- Authors
- Doty, F. D., Kulkarni, J., Turner, C., Entzminger, G., & Bielecki, A.
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2006-10
- Volume
- 182
- Issue
- 2
- Pages
- 239-253
- ISSN
- 1090-7807
- Cited by
- 74
- References
- 0
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using a cross-coil to reduce RF heating by an order of magnitude in triple-resonance multinuclear MAS at high fields. https://app.cochat.ai/papers/10.1016/j.jmr.2006.06.031
- The paper
- Doty, F. D., Kulkarni, J., Turner, C., Entzminger, G., & Bielecki, A. (2006). Using a cross-coil to reduce RF heating by an order of magnitude in triple-resonance multinuclear MAS at high fields. Journal of Magnetic Resonance. https://doi.org/10.1016/j.jmr.2006.06.031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.