Development of a 13C-optimized 1.5-mm high temperature superconducting NMR probe
Open accessThe DOI matches its Crossref record.
Abstract
We report a 1.5-mm NMR probe based on high temperature superconductors operating at 14.1 T optimized for 13C detection. The probe has a total sample volume of about 35 microliters (μL) with an active volume of 20 μL and provides exceptional mass sensitivity for 13C detection. The probe also has excellent 1H sensitivity and employs a 2H channel lock; 15N irradiation capability can be added in the future. The coils are cooled to about 20 K using a standard Agilent cryogenic refrigeration system, and the sample temperature is regulated near room temperature. The coil design considerations are discussed in detail. This probe is ideal for directly detected 13C NMR experiments for natural products chemistry and metabolomics applications, for which 35 μL is an optimal sample volume. The outstanding 13C sensitivity of this probe allowed us to directly determine the 13C connectivity on 1.1 mg of natural abundance histidine using an INADEQUATE experiment. We demonstrated the utility of this probe for 13C-based metabolomics using a synthetic mixture of common natural abundance metabolites whose concentrations ranged from 1 to 5 mM (40 to 200 nmol).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The future of NMR-based metabolomics
Markley, J. L., Brüschweiler, R., Edison, A. S., Eghbalnia, H. R., Powers, R., Raftery, D., & Wishart, D. S. (2017) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2016.08.001 · Cited by 882
Self-citationNMR Spectroscopy for Metabolomics and Metabolic Profiling
Larive, C. K., Barding, G. A., & Dinges, M. M. (2015) · Analytical Chemistry · doi:10.1021/ac504075g · Cited by 228
Lipotoxicity in steatohepatitis occurs despite an increase in tricarboxylic acid cycle activity
Patterson, R. E., Kalavalapalli, S., Williams, C. M., Nautiyal, M., Mathew, J. T., Martinez, J., Reinhard, M. K., McDougall, D. J., Rocca, J. R., Yost, R. A., et al. (2016) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00492.2015 · Cited by 161
Plant metabolomics: A new strategy and tool for quality evaluation of Chinese medicinal materials
Xiao, Q., Mu, X., Liu, J., Li, B., Liu, H., Zhang, B., & Xiao, P. (2022) · Chinese Medicine · doi:10.1186/s13020-022-00601-y · Cited by 104
Metadata
- Authors
- Ramaswamy, V., Hooker, J. W., Withers, R. S., Nast, R. E., Brey, W. W., & Edison, A. S.
- Venue
- Journal of Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2013-10
- Volume
- 235
- Pages
- 58-65
- ISSN
- 1090-7807 (ISSN-L)
- OpenAlex
- W1985194885
- Cited by
- 76
- References
- 0
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a 13C-optimized 1.5-mm high temperature superconducting NMR probe. https://app.cochat.ai/papers/10.1016/j.jmr.2013.07.012
- The paper
- Ramaswamy, V., Hooker, J. W., Withers, R. S., Nast, R. E., Brey, W. W., & Edison, A. S. (2013). Development of a 13C-optimized 1.5-mm high temperature superconducting NMR probe. Journal of Magnetic Resonance. https://doi.org/10.1016/j.jmr.2013.07.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.