Development and application of a High-Resolution mass spectrometry method for the detection of fentanyl analogs in urine and serum
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Introduction: The use of illicitly manufactured synthetic opioids, specifically fentanyl and its analogs, has escalated exponentially in the United States over the last decade. Due to the targeted nature of drug detection methods in clinical laboratories and the ever-evolving list of synthetic opioids of concern, alternative analytical approaches are needed. Methods: Using the fentanyl analog screening (FAS) kit produced by the Centers for Disease Control and Prevention (CDC), we developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) synthetic opioid spectral library and data acquisition method using information dependent acquisition of product ion spectra. Chromatographic retention times, limits of detection and matrix effects, in urine and serum, for the synthetic opioids in the FAS kit (n = 150) were established. All urine and serum specimens sent to a clinical toxicology laboratory for comprehensive drug testing in 2019 (n = 856) and 2021 (n = 878) were analyzed with the FAS LC-HRMS library to determine the prevalence of fentanyl analogs and other synthetic opioids, retrospectively (2019) and prospectively (2021). Results: The limit of detection (LOD) of each opioid ranged from 1 to 10 ng/mL (median, 2.5 ng/mL) in urine and 0.25-2.5 ng/mL (median, 0.5 ng/mL) in serum. Matrix effects ranged from -79 % to 86 % (median, -37 %) for urine, following dilution and direct analysis, and -80 % to 400 % (median, 0 %) for serum, following protein precipitation. The prevalence of fentanyl/fentanyl analogs in serum samples increased slightly from 2019 to 2021 while it remained the same in urine. There were only 2 samples identified that contained a fentanyl analog without the co-occurrence of fentanyl or fentanyl metabolites. Analysis of the established MS/MS spectral library revealed characteristic fragmentation patterns in most fentanyl analogs, which can be used for structure elucidation and drug identification of future analogs. Conclusions: The LC-HRMS method was capable of detecting fentanyl analogs in routine samples sent for comprehensive drug testing. The method can be adapted to accommodate testing needs for the evolving opioid epidemic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
UpSetR: an R package for the visualization of intersecting sets and their properties
Conway, J. R., Lex, A., & Gehlenborg, N. (2017) · Bioinformatics · doi:10.1093/bioinformatics/btx364 · Cited by 3,586
A review of the use of fentanyl analgesia in the management of acute pain in adults.
Peng, P. W. H., & Sandler, A. N. (1999) · Anesthesiology · doi:10.1097/00000542-199902000-00034 · Cited by 408
Cited by
Testing the test strips: laboratory performance of fentanyl test strips
Halifax, J. C., Lim, L., Ciccarone, D., & Lynch, K. L. (2024) · Harm Reduction Journal · doi:10.1186/s12954-023-00921-8 · Cited by 45
“Eleven different fentanyl analogs and synthetic opioids have been identified in recent drug seizures [10], although hundreds are known to exist and more theoretically possible [11, 12].”
BackgroundSelf-citationPalmquist, K. B., Truver, M. T., Shoff, E. N., Krotulski, A. J., & Swortwood, M. J. (2023) · Journal of Forensic Sciences · doi:10.1111/1556-4029.15282 · Cited by 39
“, MSE, MS/MSALL), likely proprietary to the instrument, ranging from product ion scanning to varying approaches of data independent acquisition [24,28].”
BackgroundMethodInfluentialDugues, P., Rabai, A., Chenorhokian, S., Pfau, G., Cherki, S., Bellouard, M., Alvarez, J. C., & Larabi, I. A. (2025) · Toxicologie Analytique et Clinique · doi:10.1016/j.toxac.2025.07.002 · Cited by 6
Metadata
- Authors
- Zhang, Y., Halifax, J. C., Tangsombatvisit, C., Yun, C., Pang, S., Hooshfar, S., Wu, A. H. B., & Lynch, K. L.
- Venue
- Journal of Mass Spectrometry and Advances in the Clinical Lab
- Publisher
- Stanford University Press
- Published
- 2022-11
- Volume
- 26
- Pages
- 1-6
- ISSN
- 2667-145X (ISSN-L)
- OpenAlex
- W4286566147
- Cited by
- 37
- References
- 2
- FWCI
- 20.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and application of a High-Resolution mass spectrometry method for the detection of fentanyl analogs in urine and serum. https://app.cochat.ai/papers/10.1016/j.jmsacl.2022.07.005
- The paper
- Zhang, Y., Halifax, J. C., Tangsombatvisit, C., Yun, C., Pang, S., Hooshfar, S., Wu, A. H. B., & Lynch, K. L. (2022). Development and application of a High-Resolution mass spectrometry method for the detection of fentanyl analogs in urine and serum. Journal of Mass Spectrometry and Advances in the Clinical Lab. https://doi.org/10.1016/j.jmsacl.2022.07.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.