The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand
Open accessAbstract
Background Advanced motorized prosthetic devices are currently controlled by EMG signals generated by residual muscles and recorded by surface electrodes on the skin. These surface recordings are often inconsistent and unreliable, leading to high prosthetic abandonment rates for individuals with upper limb amputation. Surface electrodes are limited because of poor skin contact, socket rotation, residual limb sweating, and their ability to only record signals from superficial muscles, whose function frequently does not relate to the intended prosthetic function. More sophisticated prosthetic devices require a stable and reliable interface between the user and robotic hand to improve upper limb prosthetic function. New Method Implantable Myoelectric Sensors (IMES®) are small electrodes intended to detect and wirelessly transmit EMG signals to an electromechanical prosthetic hand via an electromagnetic coil built into the prosthetic socket. This system is designed to simultaneously capture EMG signals from multiple residual limb muscles, allowing the natural control of multiple degrees of freedom simultaneously. Results We report the status of the first FDA-approved clinical trial of the IMES® System. This study is currently in progress, limiting reporting to only preliminary results. Comparison with Existing Methods Our first subject has reported the ability to accomplish a greater variety and complexity of tasks in his everyday life compared to what could be achieved with his previous myoelectric prosthesis. Conclusion The interim results of this study indicate the feasibility of utilizing IMES® technology to reliably sense and wirelessly transmit EMG signals from residual muscles to intuitively control a three degree-of-freedom prosthetic arm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
Research works printed but not linked: 12
- Atkins, 1996, Epidemiologic over-view of individuals with upper-limb loss and their reported research priorities, J Prosthet Orthot, 8, 2, 10.1097/00008526-199600810-00003 · DOI · Paper page
- Biddis, 2007, Upper limb prosthesis use and abandonment: a survey of the last 25 years, Prosthet Orthot Int, 31, 236, 10.1080/03093640600994581 · DOI · Paper page
- Gailey, 2008, Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use, J Rehabil Res Dev, 45
- Jones, 1999, Save that arm: a study of problems in the remaining arm of unilateral upper limb amputees, Prosthet Orthot Int, 23, 55, 10.3109/03093649909071611 · doi:10.3109/03093649909071611
- Kuiken, 2009, Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms, JAMA, 301, 619, 10.1001/jama.2009.116 · DOI · Paper page
- Lindner, 2009, Assessment of capacity for myoelectric control: evaluation of construct and rating scale, J Rehabil Med, 41, 467, 10.2340/16501977-0361 · doi:10.2340/16501977-0361
- Lowery, 2006, Simulation of intramuscular EMG signals detected using implantable myoelectric sensors (IMES), IEEE Trans Biomed Eng, 53, 1926, 10.1109/TBME.2006.881774 · DOI
- McFarland, 2010, Unilateral upper-limb loss: satisfaction and prosthetic-device use in veterans and service members from Vietnam and OIF/OEF conflicts, JRRD, 47, 299, 10.1682/JRRD.2009.03.0027 · DOI · Paper page
- Scheme, 2011, Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use, JRRD, 48, 643, 10.1682/JRRD.2010.09.0177 · DOI · Paper page
- Weir, 2009, Implantable myoelectric sensors (IMESs) for intramuscular electromyogram recording, IEEE Trans Biomed Eng, 56, 159, 10.1109/TBME.2008.2005942 · DOI · Paper page
- Wolf, 2013, Comparison of the power knee and C-leg during step-up and sit-to-stand tasks, Gait Posture, 38, 397, 10.1016/j.gaitpost.2013.01.007 · doi:10.1016/j.gaitpost.2013.01.007
- Ziegler-Graham, 2008, Estimating the prevalence of limb loss in the United States: 2005 to 2050, Arch Phys Med Rehabil, 89, 422, 10.1016/j.apmr.2007.11.005 · DOI · Paper page
Cited by
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
Sim, K., Rao, Z., Zou, Z., Ershad, F., Lei, J., Thukral, A., Chen, J., Huang, Q.-A., Xiao, J., & Yu, C. (2019) · Science Advances · doi:10.1126/sciadv.aav9653 · Cited by 305
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Clemente, F., D'Alonzo, M., Controzzi, M., Edin, B. B., & Cipriani, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2500586 · Cited by 209
Salminger, S., Sturma, A., Hofer, C., Evangelista, M., Perrin, M., Bergmeister, K. D., Roche, A. D., Hasenoehrl, T., Dietl, H., Farina, D., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6306 · Cited by 139
“Despite the potential high impact of IMES for man-machine interfacing in robotics, so far, there has been only one case report of their use in humans (16).”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Pasquina, P. F., Evangelista, M., Carvalho, A. J., Lockhart, J., Griffin, S., Nanos, G., McKay, P., Hansen, M., Ipsen, D., Vandersea, J., Butkus, J., Miller, M., Murphy, I., & Hankin, D.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2015-04
- Volume
- 244
- Pages
- 85-93
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2067214465
- Cited by
- 205
- References
- 4
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- Alfred Mann Foundation
- National Institutes of Health (R01EB001672)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand. https://app.cochat.ai/papers/10.1016/j.jneumeth.2014.07.016
- The paper
- Pasquina, P. F., Evangelista, M., Carvalho, A. J., Lockhart, J., Griffin, S., Nanos, G., McKay, P., Hansen, M., Ipsen, D., Vandersea, J., Butkus, J., Miller, M., Murphy, I., & Hankin, D. (2015). First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand. Journal of Neuroscience Methods. https://doi.org/10.1016/j.jneumeth.2014.07.016