The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
EEG source localization: Sensor density and head surface coverage
Open accessAbstract
BACKGROUND: The accuracy of EEG source localization depends on a sufficient sampling of the surface potential field, an accurate conducting volume estimation (head model), and a suitable and well-understood inverse technique. The goal of the present study is to examine the effect of sampling density and coverage on the ability to accurately localize sources, using common linear inverse weight techniques, at different depths. Several inverse methods are examined, using the popular head conductivity. NEW METHOD: Simulation studies were employed to examine the effect of spatial sampling of the potential field at the head surface, in terms of sensor density and coverage of the inferior and superior head regions. In addition, the effects of sensor density and coverage are investigated in the source localization of epileptiform EEG. RESULTS: Greater sensor density improves source localization accuracy. Moreover, across all sampling density and inverse methods, adding samples on the inferior surface improves the accuracy of source estimates at all depths. COMPARISON WITH EXISTING METHODS: More accurate source localization of EEG data can be achieved with high spatial sampling of the head surface electrodes. CONCLUSIONS: The most accurate source localization is obtained when the voltage surface is densely sampled over both the superior and inferior surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Finite Element Method in Electromagnetics
Jin, J. (1993) · Cited by 3,869
Standardized low-resolution brain electromagnetic tomography (sLORETA): technical details.
Pascual-Marqui, R. D. (2002) · PubMed · Cited by 3,329
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Surgical Treatment of the Epilepsies
Kotagal, P. (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199407000-00009 · Cited by 2,747
Report of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Finite element method in electromagnetics
Ming, J. J. (2002) · International Linear Collider · Cited by 2,017
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909
Cited by
Virtual Reality for Anxiety Reduction Demonstrated by Quantitative EEG: A Pilot Study
Tarrant, J., Viczko, J., & Cope, H. (2018) · Frontiers in Psychology · doi:10.3389/fpsyg.2018.01280 · Cited by 198
Scalp and Source Power Topography in Sleepwalking and Sleep Terrors: A High-Density EEG Study
Castelnovo, A., Riedner, B. A., Smith, R. F., Tononi, G., Boly, M., & Benca, R. M. (2016) · Sleep · doi:10.5665/sleep.6162 · Cited by 72
Temporal irreversibility of large-scale brain dynamics in Alzheimer's disease
Cruzat, J., Herzog, R., Prado, P., Sanz-Perl, Y., Gonzalez-Gomez, R., Moguilner, S., Kringelbach, M. L., Deco, G., Tagliazucchi, E., & Ibañez, A. (2023) · The Journal of Neuroscience · doi:10.1523/jneurosci.1312-22.2022 · Cited by 57
Identifying good practices for detecting inter-regional linear functional connectivity from EEG
Pellegrini, F., Delorme, A., Nikulin, V., & Haufe, S. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120218 · Cited by 43
Shenoy Handiru, V., Vinod, A. P., & Guan, C. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6baf · Cited by 36
Metadata
- Authors
- Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 256
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W1680137270
- Cited by
- 356
- References
- 70
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EEG source localization: Sensor density and head surface coverage. https://app.cochat.ai/papers/10.1016/j.jneumeth.2015.08.015
- The paper
- Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D. (2015). EEG source localization: Sensor density and head surface coverage. Journal of Neuroscience Methods. https://doi.org/10.1016/j.jneumeth.2015.08.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.