The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
EEG source localization: Sensor density and head surface coverage
Open accessAbstract
BACKGROUND: The accuracy of EEG source localization depends on a sufficient sampling of the surface potential field, an accurate conducting volume estimation (head model), and a suitable and well-understood inverse technique. The goal of the present study is to examine the effect of sampling density and coverage on the ability to accurately localize sources, using common linear inverse weight techniques, at different depths. Several inverse methods are examined, using the popular head conductivity. NEW METHOD: Simulation studies were employed to examine the effect of spatial sampling of the potential field at the head surface, in terms of sensor density and coverage of the inferior and superior head regions. In addition, the effects of sensor density and coverage are investigated in the source localization of epileptiform EEG. RESULTS: Greater sensor density improves source localization accuracy. Moreover, across all sampling density and inverse methods, adding samples on the inferior surface improves the accuracy of source estimates at all depths. COMPARISON WITH EXISTING METHODS: More accurate source localization of EEG data can be achieved with high spatial sampling of the head surface electrodes. CONCLUSIONS: The most accurate source localization is obtained when the voltage surface is densely sampled over both the superior and inferior surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Finite Element Method in Electromagnetics
Jin, J. (1993) · Cited by 3,869
Standardized low-resolution brain electromagnetic tomography (sLORETA): technical details.
Pascual-Marqui, R. D. (2002) · PubMed · Cited by 3,329
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Surgical Treatment of the Epilepsies
Kotagal, P. (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199407000-00009 · Cited by 2,747
Report of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Finite element method in electromagnetics
Ming, J. J. (2002) · International Linear Collider · Cited by 2,017
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909
Surgical treatment of the epilepsies
Engel, J. (1993) · Raven Press eBooks · Cited by 1,778
Baillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Reference-free identification of components of checkerboard-evoked multichannel potential fields
Lehmann, D., & Skrandies, W. (1980) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(80)90419-8 · Cited by 1,552
Electric Fields of the Brain: The Neurophysics of EEG
Fermaglich, J. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03320380071046 · Cited by 1,543
Review on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
Spatial sampling of head electrical fields: the geodesic sensor net
Tucker, D. M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90121-b · Cited by 751
Self-citationGood practice for conducting and reporting MEG research
Gross, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O., Jerbi, K., Litvak, V., Maess, B., Oostenveld, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 738
Spatiotemporal Analysis of Multichannel EEG: CARTOOL
Brunet, D., Murray, M. M., & Michel, C. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/813870 · Cited by 731
Review on solving the forward problem in EEG source analysis
Hallez, H., Vanrumste, B., Grech, R., Muscat, J., De Clercq, W., Vergult, A., D'Asseler, Y., Camilleri, K. P., Fabri, S. G., Van Huffel, S., et al. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-46 · Cited by 527
The conductivity of the human skull: results of in vivo and in vitro measurements
Oostendorp, T. F., Delbeke, J., & Stegeman, D. F. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880100 · Cited by 467
EEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
Epileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Source localization using recursively applied and projected (RAP) MUSIC
Mosher, J. C., & Leahy, R. M. (1999) · IEEE Transactions on Signal Processing · doi:10.1109/78.740118 · Cited by 398
Spatial spectra of scalp EEG and EMG from awake humans
Freeman, W. J., Holmes, M. D., Burke, B. C., & Vanhatalo, S. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00045-2 · Cited by 370
Electrical neuroimaging based on biophysical constraints
Grave de Peralta Menendez, R., Murray, M. M., Michel, C. M., Martuzzi, R., & Gonzalez Andino, S. L. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.051 · Cited by 365
Recursive MUSIC: A framework for EEG and MEG source localization
Mosher, J. C., & Leahy, R. M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.725331 · Cited by 362
Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320
An improved boundary element method for realistic volume-conductor modeling
Fuchs, M., Drenckhahn, R., Wischmann, H., & Wagner, M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704867 · Cited by 299
Moretti, D. (2003) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(02)00153-8 · Cited by 253
Estimating the spatial Nyquist of the human EEG
Srinivasan, R., Tucker, D. M., & Murias, M. (1998) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03209412 · Cited by 247
Self-citationImproving source reconstructions by combining bioelectric and biomagnetic data
Fuchs, M., Wagner, M., Wischmann, H.-A., Köhler, T., Theißen, A., Drenckhahn, R., & Buchner, H. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00046-7 · Cited by 239
A fast method for forward computation of multiple-shell spherical head models
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90113-9 · Cited by 230
Goncalves, S. I., de Munck, J. C., Verbunt, J. P. A., Bijma, F., Heethaar, R. M., & Lopes da Silva, F. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812164 · Cited by 219
Lai, Y., van Drongelen, W., Ding, L., Hecox, K. E., Towle, V. L., Frim, D. M., & He, B. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.08.017 · Cited by 215
Wipf, D. P., Owen, J. P., Attias, H. T., Sekihara, K., & Nagarajan, S. S. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.083 · Cited by 214
EEG Source Connectivity Analysis: From Dense Array Recordings to Brain Networks
Hassan, M., Dufor, O., Merlet, I., Berrou, C., & Wendling, F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105041 · Cited by 208
Zhang, Z. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/3/001 · Cited by 192
Hauk, O., Wakeman, D. G., & Henson, R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.053 · Cited by 189
128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision
Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200403000-00001 · Cited by 183
Yao, J., & Dewald, J. P. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.11.036 · Cited by 161
Sensitivity distributions of EEG and MEG measurements
Malmivuo, J. A., Suihko, V., & Eskola, H. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554766 · Cited by 150
Effect of EEG electrode number on epileptic source localization in pediatric patients
Sohrabpour, A., Lu, Y., Kankirawatana, P., Blount, J., Kim, H., & He, B. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.038 · Cited by 149
Estimation of in vivo brain-to-skull conductivity ratio in humans
Zhang, Y., van Drongelen, W., & He, B. (2006) · Applied Physics Letters · doi:10.1063/1.2398883 · Cited by 145
EEG Source Imaging in Pediatric Epilepsy Surgery: A New Perspective in Presurgical Workup
Sperli, F., Spinelli, L., Seeck, M., Kurian, M., Michel, C. M., & Lantz, G. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00550.x · Cited by 141
Regional head tissue conductivity estimation for improved EEG analysis
Tucker, D. M., Eriksen, K. J., & Ferrée, T. C. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.887939 · Cited by 133
Self-citationElectromyogenic Artifacts and Electroencephalographic Inferences
Shackman, A. J., McMenamin, B. W., Slagter, H. A., Maxwell, J. S., Greischar, L. L., & Davidson, R. J. (2009) · Brain Topography · doi:10.1007/s10548-009-0079-4 · Cited by 125
Electromyogenic artifacts and electroencephalographic inferences revisited
McMenamin, B. W., Shackman, A. J., Greischar, L. L., & Davidson, R. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.057 · Cited by 122
Medial Prefrontal Theta Bursts Precede Rapid Motor Responses during Visual Selective Attention
Arnaud Delorme, A., Westerfield, M., & Makeig, S. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.3477-07.2007 · Cited by 119
A systematic evaluation of the spherical model accuracy in EEG dipole localization
Yvert, B., Bertrand, O., Thévenet, M., Echallier, J. F., & Pernier, J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0921-884x(97)96611-x · Cited by 116
Geodesic photogrammetry for localizing sensor positions in dense-array EEG
Russell, G. S., Eriksen, K. J., Poolman, P., Luu, P., & Tucker, D. M. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.12.022 · Cited by 104
Self-citationLocalizing Acute Stroke-related EEG Changes: Assessing the Effects of Spatial Undersampling
Luu, P., Tucker, D. M., Englander, R. N., Lockfeld, A. J., Lutsep, H. L., & Oken, B. (2001) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200107000-00002 · Cited by 98
Self-citationEstimating Brain Conductivities and Dipole Source Signals With EEG Arrays
Gutiérrez, D., Nehorai, A., & Muravchik, C. H. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836507 · Cited by 88
Spatial patterning of the neonatal EEG suggests a need for a high number of electrodes
Odabaee, M., Freeman, W. J., Colditz, P. B., Ramon, C., & Vanhatalo, S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.11.062 · Cited by 80
Ryynanen, O., Hyttinen, J., & Malmivuo, J. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873744 · Cited by 74
Dense array EEG: Methodology and new hypothesis on epilepsy syndromes
Holmes, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01505.x · Cited by 68
Surface Laplacian of Central Scalp Electrical Signals is Insensitive to Muscle Contamination
Fitzgibbon, S. P., Lewis, T. W., Powers, D. M. W., Whitham, E. W., Willoughby, J. O., & Pope, K. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2195662 · Cited by 67
ICA-based muscle artefact correction of EEG data: What is muscle and what is brain?
Olbrich, S., Jödicke, J., Sander, C., Himmerich, H., & Hegerl, U. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.256 · Cited by 66
Ryynanen, O., Hyttinen, J., Laarne, P., & Malmivuo, J. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.828036 · Cited by 59
Effect of Skull Resistivity on the Spatial Resolutions of EEG and MEG
Malmivuo, J. A., & Suihko, V. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827255 · Cited by 54
Laarne, P., Tenhunen, M. L., Hyttinen, J., & Eskola, H. J. (2000) · Brain Topography · doi:10.1023/a:1023422504025 · Cited by 50
High-resolution EEG: on the cortical equivalent dipole layer imaging
He, B., Yao, D., & Lian, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00740-4 · Cited by 44
Effect of Brain-to-Skull Conductivity Ratio on EEG Source Localization Accuracy
Wang, G., & Ren, D. (2013) · BioMed Research International · doi:10.1155/2013/459346 · Cited by 34
Feng, R., Hu, J., Pan, L., Wu, J., Lang, L., Jiang, S., Gu, X., Guo, J. X., & Zhou, L. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.03.009 · Cited by 32
Conductivity Analysis for High-Resolution EEG
Turovets, S. I., Poolman, P., Salman, A. M., Malony, A. D., & Tucker, D. M. (2008) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2008.358 · Cited by 15
Self-citationSensor density and head surface coverage in EEG source localization
Song, J., Davey, C., Poulsen, C., Turovets, S. I., Luu, P., & Tucker, D. M. (2014) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2014.6867947 · Cited by 10
Self-citationMalony, A. D., Salman, A. M., Turovets, S. I., Tucker, D. M., Vasily, V., Li, K., Eun, S. J., Biersdorff, S., Davey, C., Hoge, C. C., et al. (2011) · Studies in health technology and informatics · doi:10.3233/978-1-60750-706-2-329 · Cited by 7
Self-citation
Cited by
EEG-Neurofeedback as a Tool to Modulate Cognition and Behavior: A Review Tutorial
Enriquez-Geppert, S., Huster, R. J., & Herrmann, C. S. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00051 · Cited by 515
Virtual Reality for Anxiety Reduction Demonstrated by Quantitative EEG: A Pilot Study
Tarrant, J., Viczko, J., & Cope, H. (2018) · Frontiers in Psychology · doi:10.3389/fpsyg.2018.01280 · Cited by 198
Scalp and Source Power Topography in Sleepwalking and Sleep Terrors: A High-Density EEG Study
Castelnovo, A., Riedner, B. A., Smith, R. F., Tononi, G., Boly, M., & Benca, R. M. (2016) · Sleep · doi:10.5665/sleep.6162 · Cited by 72
Temporal irreversibility of large-scale brain dynamics in Alzheimer's disease
Cruzat, J., Herzog, R., Prado, P., Sanz-Perl, Y., Gonzalez-Gomez, R., Moguilner, S., Kringelbach, M. L., Deco, G., Tagliazucchi, E., & Ibañez, A. (2023) · The Journal of Neuroscience · doi:10.1523/jneurosci.1312-22.2022 · Cited by 57
Identifying good practices for detecting inter-regional linear functional connectivity from EEG
Pellegrini, F., Delorme, A., Nikulin, V., & Haufe, S. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120218 · Cited by 43
Metadata
- Authors
- Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 256
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W1680137270
- Cited by
- 356
- References
- 70
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.