Geometric optimization of aerogel composites for high temperature thermal insulation applications
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Abstract Silica aerogel has attracted great interest in thermal insulation applications due to its ultralow thermal conductivity. However, silica aerogel is transparent to the infrared radiation in the range of 3-8 µm, making them be not suitable for high temperature thermal insulation applications. Here, we developed an optimization method considering both thermal radiation and heat conduction to design the geometric structures of aerogel composites with minimized thermal conductivity. The results show that when the ambient temperature is lower than ~ 600 K, the additives with low thermal conductivity are preferred. When the ambient temperature is higher than ~ 600 K, the additives with high extinction coefficients are needed. The additives with a broad size distribution could enable the aerogel composites to have an optimal thermal insulation performance in the environment with a changing temperature. The work provides a guideline for the geometric design of aerogel composites for high temperature thermal insulation applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Overview on Silica Aerogels Synthesis and Different Mechanical Reinforcing Strategies
Maleki, H., Durães, L., & Portugal, A. (2014) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2013.10.017 · Cited by 740
Tailoring Mechanical Properties of Aerogels for Aerospace Applications
Randall, J. P., Meador, M. A. B., & Jana, S. C. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am200007n · Cited by 579
Nonlocal and Nonequilibrium Heat Conduction in the Vicinity of Nanoparticles
Chen, G. (1996) · Journal of Heat Transfer · doi:10.1115/1.2822665 · Cited by 382
Transport properties of gas in silica aerogel
Zeng, S. Q., Hunt, A., & Greif, R. (1995) · Journal of Non-Crystalline Solids · doi:10.1016/0022-3093(95)00052-6 · Cited by 155
Heat transfer modeling in vacuum insulation panels containing nanoporous silicas—A review
Bouquerel, M., Duforestel, T., Baillis, D., & Rusaouen, G. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.07.034 · Cited by 128
Zhao, J.-J., Duan, Y.-Y., Wang, X.-D., & Wang, B.-X. (2012) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2012.02.037 · Cited by 81
Cited by
Stergiou, K., Ntakolia, C., Varytis, P., Koumoulos, E., Karlsson, P., & Moustakidis, S. (2023) · Computational Materials Science · doi:10.1016/j.commatsci.2023.112031 · Cited by 161
Thermal Insulation Performance of Aerogel Nano-Porous Materials: Characterization and Test Methods
Lou, F., Dong, S., Zhu, K., Chen, X., & Ma, Y. (2023) · Gels · doi:10.3390/gels9030220 · Cited by 76
(2022) · doi:10.1115/1.4052343 · Cited by 6
Metadata
- Authors
- Liu, H., Hu, M., Jiao, J., & Li, Z.
- Venue
- Journal of Non-Crystalline Solids
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 547
- Pages
- 120306
- ISSN
- 0022-3093 (ISSN-L)
- OpenAlex
- W3044974382
- Cited by
- 36
- References
- 6
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.