CoChat

Comparative responsiveness of outcome measures for total knee arthroplasty

Open access
Giesinger, K., Hamilton, D.F., Jost, B., Holzner, B., Giesinger, J.M. · 2014 · Osteoarthritis and Cartilage
Cited by 168

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The aim of this study was to compare the responsiveness of various patient-reported outcome measures (PROMs) and clinician-reported outcomes following total knee arthroplasty (TKA) over a 2-year period. METHODS: Data were collected in a prospective cohort study of primary TKA. Patients who had completed Forgotten Joint Score-12 (FJS-12), Western Ontario and McMaster Universities (WOMAC) osteoarthritis (OA) index, EQ-5D, Knee Society Score and range of movement (ROM) assessment were included. Five time points were assessed: pre-operative, 2 months, 6 months, 1 year and 2 years post-operative. RESULTS: Data from 98 TKAs were available for analysis. Largest effect sizes (ES) for change from pre-operative to 2-month follow-up were observed for the Knee Society Score (KSS) Knee score (1.70) and WOMAC Total (-1.50). For the period from 6 months to 1 year the largest ES for change were shown by the FJS-12 (0.99) and the KSS Function Score (0.88). The EQ-5D showed the strongest ceiling effect at 1-year follow-up with 84.4% of patients scoring the maximum score. ES for the time from 1- to 2-year follow-up were largest for the FJS-12 (0.50). All other outcome measures showed ES equal or below 0.30. CONCLUSION: Outcome measures differ considerably in responsiveness, especially beyond one year post-operatively. Joint-specific outcome measures are more responsive than clinician-reported or generic health outcome tools. The FJS-12 was the most responsive of the tools assessed; suggesting that joint awareness may be a more discerning measure of patient outcome than traditional PROMs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.joca.2013.11.001

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 168

Metadata

Authors
Giesinger, K., Hamilton, D. F., Jost, B., Holzner, B., & Giesinger, J. M.
Venue
Osteoarthritis and Cartilage
Publisher
Elsevier BV
Published
2014-02
Volume
22
Issue
2
Pages
184-189
ISSN
1063-4584 (ISSN-L)
OpenAlex
W2079127173
Cited by
168
References
2
FWCI
8.98
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative responsiveness of outcome measures for total knee arthroplasty. https://app.cochat.ai/papers/10.1016/j.joca.2013.11.001
The paper
Giesinger, K., Hamilton, D. F., Jost, B., Holzner, B., & Giesinger, J. M. (2014). Comparative responsiveness of outcome measures for total knee arthroplasty. Osteoarthritis and Cartilage. https://doi.org/10.1016/j.joca.2013.11.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.