The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The effect of hydrogen gas evolution of magnesium implant on the postimplantation mortality of rats
Open accessAbstract
BACKGROUND/OBJECTIVE: degradation of magnesium implants. In many studies, the gas cavity is mostly punctured out subcutaneously. However, this procedure becomes inapplicable in certain internal surgeries; therefore, the effect of this gas cavity is worth further assessment. METHODS: In this study, we investigated the effect of hydrogen gas evolution on the mortality of rats and analysed the whole body capacity to relieve the gas. Porous pure-magnesium implants were implanted in the femoral bone defect of adult Sprague-Dawley rats up to 18 days, and their survival rate was calculated while the gas cavity size was measured, and its effect was analysed with support of radiographic and blood analysis. RESULTS: The gas cavity was rapidly formed surrounding the implantation site and obviously decreased the rats' survival rate. The gas was observed to swell the surrounding implantation site by filling the loose compartments and then dispersing subcutaneously to other areas. CONCLUSION: The rat's whole body capacity was unable to tolerate the rapid and persistent hydrogen gas cavity formation as shown by high postimplantation mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on macrophage responses to biomaterials
Xia, Z., & Triffitt, J. T. (2006) · Biomedical Materials · doi:10.1088/1748-6041/1/1/r01 · Cited by 418
Cited by
Biodegradable magnesium-based implants in orthopedics-a general review and perspectives
Wang, J., Xu, J., Hopkins, C., Chow, D. H., & Qin, L. (2020) · Advanced Science · doi:10.1002/advs.201902443 · Cited by 574
Biodegradable magnesium‐based biomaterials: An overview of challenges and opportunities
Amukarimi, S., & Mozafari, M. (2021) · MedComm · doi:10.1002/mco2.59 · Cited by 258
Polymer bilayer-Micro arc oxidation surface coating on pure magnesium for bone implantation
Dong, J., Zhong, J., Hou, R., Hu, X., Chen, Y., Weng, H., Zhang, Z., Liu, B., Yang, S., & Peng, Z. (2023) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2023.05.003 · Cited by 33
Metadata
- Authors
- Noviana, D., Paramitha, D., Ulum, M. F., & Hermawan, H.
- Venue
- Journal of Orthopaedic Translation
- Publisher
- Elsevier BV
- Published
- 2016-04
- Volume
- 5
- Pages
- 9-15
- ISSN
- 2214-031X (ISSN-L)
- OpenAlex
- W1149656885
- Cited by
- 184
- References
- 1
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effect of hydrogen gas evolution of magnesium implant on the postimplantation mortality of rats. https://app.cochat.ai/papers/10.1016/j.jot.2015.08.003
- The paper
- Noviana, D., Paramitha, D., Ulum, M. F., & Hermawan, H. (2016). The effect of hydrogen gas evolution of magnesium implant on the postimplantation mortality of rats. Journal of Orthopaedic Translation. https://doi.org/10.1016/j.jot.2015.08.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.