CoChat

Natural deep eutectic solvents as eco-friendly and sustainable dilution medium for the determination of residual organic solvents in pharmaceuticals with static headspace-gas chromatography

Wang, Meilian, Fang, Sheng, Liang, Xianrui · 2018 · Journal of Pharmaceutical and Biomedical Analysis
Cited by 46

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

HIGHLIGHTSA simple and rapid SHS‐GC method for determination of residual solvents was proposed.The eco‐friendly NADESs are firstly used as the matrix medium for the SHS‐GC method.NADESs showed higher peak area response and superior stability.The developed method was used to detect the residual solvents in six drug substances. ABSTRACT Reported here is a simple and rapid static headspace gas chromatography (SHS‐GC) method for the determination of trace solvents including ethanol, isopropanol, n‐butanol, 1,4‐dioxane, tetrahydrofuran, acetonitrile, methanol and acetone which commonly used in drug production process. Natural deep eutectic solvents (NADESs) are firstly used as the matrix medium for this method, which provided high sensitivity for residual solvents detection. With the optimized method, validation experiments were performed and the data showed excellent linearity for all the solvents (R2 ≥ 0.999, n=7). The limits of detection (LOD) for ethanol, isopropanol, n‐butanol, 1,4‐dioxane, tetrahydrofuran, acetonitrile, methanol and acetone are 0.09, 0.08, 0.07, 0.11, 0.06, 0.10, 0.12 and 0.08&mgr;g g−1, respectively. Accuracy was checked by a recovery experiment at three different levels, and the recoveries of the tested solvents were ranged from 94.3% to 105.4%. The relative standard deviation (RSD) of each solvent for intra‐ and inter‐day precision is in the range of 0.85 to 3.65 and 1.51 to 4.53, respectively. The developed approach can be readily used for determination of the residual solvents in six active pharmaceutical ingredients including pramipexole dihydrochloride, rivaroxaban, lisinopril, ramipril, imatinib mesylate and sitagliptin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jpba.2018.06.002

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 46

Metadata

Authors
Wang, M., Fang, S., & Liang, X.
Venue
Journal of Pharmaceutical and Biomedical Analysis
Publisher
Elsevier BV
Published
2018-09
Volume
158
Pages
262-268
ISSN
0731-7085 (ISSN-L)
OpenAlex
W2807503320
Cited by
46
References
7
FWCI
2.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Natural deep eutectic solvents as eco-friendly and sustainable dilution medium for the determination of residual organic solvents in pharmaceuticals with static headspace-gas chromatography. https://app.cochat.ai/papers/10.1016/j.jpba.2018.06.002
The paper
Wang, M., Fang, S., & Liang, X. (2018). Natural deep eutectic solvents as eco-friendly and sustainable dilution medium for the determination of residual organic solvents in pharmaceuticals with static headspace-gas chromatography. Journal of Pharmaceutical and Biomedical Analysis. https://doi.org/10.1016/j.jpba.2018.06.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.