CoChat

Long-term stability of gentamicin sulfate-ethylenediaminetetraacetic acid disodium salt (EDTA-Na2) solution for catheter locks

Fiolet, Anne-Sophie, Jandot, Elise, Doucey, Pauline, Crétet, Coralie, Brunel, Célia, Pivot, Christine, Ghigo, Jean-Marc, Beloin, Christophe, Lebeaux, David, Pirot, Fabrice · 2018 · Journal of Pharmaceutical Analysis
Cited by 12

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A lock solution composed of gentamicin sulfate (5 mg/mL) and ethylenediaminetetraacetic acid disodium salt (EDTA-Na2, 30 mg/mL) could fully eradicate in vivo bacterial biofilms in totally implantable venous access ports (TIVAP). In this study, fabrication, conditioning and sterilization processes of antimicrobial lock solution (ALS) were detailed and completed by a stability study. Stability of ALS was conducted for 12 months in vial (25 °C ± 2 °C, 60% ± 5% relative humidity (RH), and at 40 °C ± 2 °C, RH 75% ± 5%) and for 24 h and 72 h in TIVAP (40 °C ± 2 °C, RH 75% ± 5%). A stability indicating HPLC assay with UV detection for simultaneous quantification of gentamicin sulfate and EDTA-Na2 was developed. ALS was assayed by ion-pairing high performance liquid chromatography (HPLC) needing gentamicin derivatization, EDTA-Na2 metallocomplexation of samples and gradient mobile phase. HPLC methods to separate four gentamicin components and EDTA-Na2 were validated. Efficiency of sterility procedure and conditioning of ALS was confirmed by bacterial endotoxins and sterility tests. Physicochemical stability of ALS was determined by visual inspection, osmolality, pH, and sub-visible particle counting. Results confirmed that the stability of ALS in vials was maintained for 12 months and 24 h and 72 h in TIVAP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jpha.2017.09.004

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 37

  1. Raad, 2007, Intravascular catheter-related infections: advances in diagnosis, prevention, and management, Lancet Infect. Dis., 7, 645, 10.1016/S1473-3099(07)70235-9 · DOI · Paper page
  2. Beloin, 2017, Understanding biofilm formation in intravascular device-related infections, Intensive Care Med., 43, 443, 10.1007/s00134-016-4480-7 · DOI
  3. Hogan, 2016, In vitro approach for identification of the most effective agents for antimicrobial lock therapy in the treatment of intravascular catheter-related infections caused by Staphylococcus aureus, Antimicrob. Agents Chemother., 60, 2923, 10.1128/AAC.02885-15 · DOI
  4. Mermel, 2009, Clinical practice guidelines for the diagnosis and management of intravascular catheter-related infection: 2009 Update by the Infectious Diseases Society of America, Clin. Infect. Dis. Off. Publ. Infect. Dis. Soc. Am., 49, 1, 10.1086/599376 · DOI · Paper page
  5. Justo, 2014, Antibiotic lock therapy: review of technique and logistical challenges, 7, 343
  6. Betjes, 2004, Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution, Nephrol. Dial. Transplant., 19, 1546, 10.1093/ndt/gfh014 · DOI · Paper page
  7. Raad, 2008, Role of ethylene diamine tetra-acetic acid (EDTA) in catheter lock solutions: EDTA enhances the antifungal activity of amphotericin B lipid complex against Candida embedded in biofilm, Int. J. Antimicrob. Agents, 32, 515, 10.1016/j.ijantimicag.2008.06.020 · DOI
  8. Weijmer, 2005, Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients, J. Am. Soc. Nephrol., 16, 2769, 10.1681/ASN.2004100870 · DOI · Paper page
  9. Liu, 2017, In vitro and in vivo activity of EDTA and antibacterial agents against the biofilm of mucoid Pseudomonas aeruginosa, Infection, 45, 23, 10.1007/s15010-016-0905-z · DOI
  10. Chauhan, 2012, Full and broad-spectrum in vivo eradication of catheter-associated biofilms using gentamicin-EDTA antibiotic lock therapy, Antimicrob. Agents Chemother., 56, 6310, 10.1128/AAC.01606-12 · DOI
  11. Ji, 2009, Effect of EDTA and methionine on preventing loss of viscosity of cellulose-based topical gel, AAPS PharmSciTech., 10, 678, 10.1208/s12249-009-9258-6 · doi:10.1208/s12249-009-9258-6
  12. Rudin, 1970, Antibacterial activity of gentamicin sulfate in tissue culture, Appl. Microbiol., 20, 989, 10.1128/am.20.6.989-990.1970 · doi:10.1128/am.20.6.989-990.1970
  13. Mullins, 2016, The impact of storage conditions upon gentamicin coated antimicrobial implants, J. Pharm. Anal., 6, 374, 10.1016/j.jpha.2016.05.002 · DOI
  14. Christianson, 1983, A comparison of a disposable membrane filtration system with a direct inoculation system for the sterility testing of veterinary biologics, J. Biol. Stand., 11, 83, 10.1016/S0092-1157(83)80030-4 · doi:10.1016/s0092-1157(83)80030-4
  15. Al-Amoud, 2002, Determination of gentamicin in urine samples after inhalation by reversed-phase high-performance liquid chromatography using pre-column derivatisation with o-phthalaldehyde, J. Chromatogr. B, 25, 89, 10.1016/S1570-0232(01)00636-5 · doi:10.1016/s1570-0232(01)00636-5
  16. Chuong, 2013, High performance liquid chromatography of gentamicin sulfate reference standards and injection USP, Int. J. Pharm. Anal., 4, 25
  17. Kuehl, 2012, Development and validation of an HPLC assay for dual detection of gentamicin sulfate and leucine from a novel dry powder for inhalation, J. Anal. Bioanal. Tech., 3, 1, 10.4172/2155-9872.1000152 · doi:10.4172/2155-9872.1000152
  18. Ruckmani, 2011, A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection, Pharm. Methods, 2, 117, 10.4103/2229-4708.84455 · doi:10.4103/2229-4708.84455
  19. Kord, 1995, A novel HPLC method for determination of EDTA in a cataract inhibiting ophthalmic drug, J. Pharm. Biomed. Anal., 13, 575, 10.1016/0731-7085(95)01254-I · doi:10.1016/0731-7085(95)01254-i
  20. Caudron, 2013, Simultaneous quantification of gentamicin and colistin sulfate in pharmaceuticals using ion-pairing and polarity gradient chromatography with low-UV detection, Chromatographia, 76, 747, 10.1007/s10337-013-2478-7 · DOI
  21. Stypulkowska, 2010, Determination of gentamicin sulphate composition and related substances in pharmaceutical preparations by LC with charged aerosol detection, Chromatographia, 72, 1225, 10.1365/s10337-010-1763-y · doi:10.1365/s10337-010-1763-y
  22. Branch, 2005, Guidelines from the International Conference on Harmonisation (ICH), J. Pharm. Biomed. Anal., 38, 798, 10.1016/j.jpba.2005.02.037 · DOI · Paper page
  23. G.A. Shabir, Validation of high-performance liquid chromatography methods for pharmaceutical analysis: Understanding the differences and similarities between validation requirements of the US Food and Drug Administration, the US Pharmacopeia and the International Conference on Harmonization, J. Chromatogr. A. 987 (2003) 57–66. · DOI · Paper page
  24. Blessy, 2014, Development of forced degradation and stability indicating studies of drugs—a review, J. Pharm. Anal., 4, 159, 10.1016/j.jpha.2013.09.003 · DOI · Paper page
  25. Sabath, 1971, Rapid microassay of gentamicin, kanamycin, neomycin, streptomycin, and vancomycin in serum or plasma, J. Lab. Clin. Med., 78, 457
  26. Andrews, 1984, A comparison of the homogeneous enzyme immunoassay and polarization fluoroimmunoassay of gentamicin, J. Antimicrob. Chemother., 14, 509, 10.1093/jac/14.5.509 · doi:10.1093/jac/14.5.509
  27. Brown, 1990, Extraction methods for quantitation of gentamicin residues from tissues using fluorescence polarization immunoassay, J. Assoc. Off. Anal. Chem., 73, 479
  28. Manyanga, 2007, Comparison of liquid chromatographic methods with direct detection for the analysis of gentamicin, J. Pharm. Biomed. Anal., 45, 257, 10.1016/j.jpba.2007.06.015 · doi:10.1016/j.jpba.2007.06.015
  29. Manyanga, 2008, Improved liquid chromatographic method with pulsed electrochemical detection for the analysis of gentamicin, J. Chromatogr. A, 1189, 347, 10.1016/j.chroma.2007.12.041 · doi:10.1016/j.chroma.2007.12.041
  30. Clarot, 2004, Determination of gentamicin sulfate and related compounds by high-performance liquid chromatography with evaporative light scattering detection, J. Chromatogr. A, 1031, 281, 10.1016/j.chroma.2003.12.032 · doi:10.1016/j.chroma.2003.12.032
  31. Megoulas, 2004, Development and validation of a novel LC/ELSD method for the quantitation of gentamicin sulfate components in pharmaceuticals, J. Pharm. Biomed. Anal., 36, 73, 10.1016/j.jpba.2004.05.018 · doi:10.1016/j.jpba.2004.05.018
  32. Joseph, 2010, Development and validation of a RP-HPLC method for the determination of gentamicin sulfate and its related substances in a pharmaceutical cream using a short pentafluorophenyl column and a charged aerosol detector, J. Pharm. Biomed. Anal., 51, 521, 10.1016/j.jpba.2009.09.002 · doi:10.1016/j.jpba.2009.09.002
  33. Curiel, 2007, Analysis of underivatized gentamicin by capillary electrophoresis with UV detection, J. Pharm. Biomed. Anal., 44, 49, 10.1016/j.jpba.2007.01.029 · doi:10.1016/j.jpba.2007.01.029
  34. Vučićević-Prčetić, 2011, Development and validation of liquid chromatography tandem mass spectrometry methods for the determination of gentamicin, lincomycin, and spectinomycin in the presence of their impurities in pharmaceutical formulations, J. Pharm. Biomed. Anal., 56, 736, 10.1016/j.jpba.2011.07.031 · doi:10.1016/j.jpba.2011.07.031
  35. Chissell, 1986, British pharmacopoeial gentamicin sulphate component ratio test by high-performance liquid chromatography. The effect of derivative breakdown on final result, J. Chromatogr., 369, 213, 10.1016/S0021-9673(00)90119-5 · doi:10.1016/s0021-9673(00)90119-5
  36. Albracht, 1987, Analysis of gentamicin in raw material and in pharmaceutical preparations by high-performance liquid chromatography, J. Chromatogr., 389, 306, 10.1016/S0021-9673(01)94439-5 · doi:10.1016/s0021-9673(01)94439-5
  37. Wang, 2016, Ion-pairing HPLC methods to determine EDTA and DTPA in small molecule and biological pharmaceutical formulations, J. Pharm. Anal., 6, 150, 10.1016/j.jpha.2016.01.002 · doi:10.1016/j.jpha.2016.01.002

Cited by

Metadata

Authors
Fiolet, A.-S., Jandot, E., Doucey, P., Crétet, C., Brunel, C., Pivot, C., Ghigo, J.-M., Beloin, C., Lebeaux, D., & Pirot, F.
Venue
Journal of Pharmaceutical Analysis
Publisher
Elsevier BV
Published
2018-12
Volume
8
Issue
6
Pages
386-393
ISSN
2095-1779
Cited by
12
References
1
Language
en
Licence
Funders
  • Centre de Recherche Translationnelle de I′Institut Pasteur (S- PI15007-02A)
  • French Government's Investissement d′Avenir (ANR-10-LABX-62-IBEID.)
  • Fondation pour la Recherche Médicale (DEQ. 20140329508)
  • Center for Translational Science of the Institut Pasteur (S-PI15007-02A)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.