Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 218

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution

Open access
Betjes, M. G. H., van Agteren, M.·2004·Nephrology Dialysis Transplantation

Abstract

BACKGROUND: The use of haemodialysis catheters is complicated by catheter-related sepsis. Intraluminal colonization of the catheter with bacteria is important in the pathogenesis of catheter-related sepsis. The use of a catheter lock solution containing the antimicrobial taurolidine might prevent bacterial colonization, thereby reducing the incidence of catheter-related sepsis. METHODS: In a randomized prospective trial, patients receiving a dialysis catheter were included and catheters were locked with either heparin or a citrate-taurolidine-containing solution. Blood cultures drawn from the catheter lumen were routinely taken every 2 weeks and at time of removal of the catheter to detect bacterial colonization. Catheter-related sepsis and exit-site infections were registered for both groups. RESULTS: A total of 76 catheters were inserted in 58 patients. The incidence of catheter colonization progressed slowly over time with no differences between dialysis catheters filled with heparin or citrate-taurolidine-containing solution. The number of exit-site infections was also similar between both groups. In the heparin group, four cases of catheter-related sepsis occurred as opposed to no sepsis episodes in the patients with catheters locked with the citrate-taurolidine-containing solution (P<0.5). No side effects with the use of citrate-taurolidine catheter lock solution were noted. CONCLUSIONS: This study shows that catheter filling with a solution containing the antimicrobial taurolidine may significantly reduce the incidence of catheter-related sepsis. Taurolidine appears to be effective and safe and does not carry the risk for side effects that have been reported for other antimicrobial lock solutions containing gentamicin or high concentrations of citrate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfh014

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 218

Metadata

Authors
Betjes, M. G. H., & van Agteren, M.
Venue
Nephrology Dialysis Transplantation
Published
2004-02-19
Volume
19
Issue
6
Pages
1546-1551
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2154637040
Cited by
218
References
1
FWCI
19.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution. https://app.cochat.ai/papers/10.1093/ndt/gfh014
The paper
Betjes, M. G. H., & van Agteren, M. (2004). Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfh014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.