The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Determination of the quantum yields of the potassium ferrioxalate and potassium iodide–iodate actinometers and a method for the calibration of radiometer detectors
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new sensitive chemical actinometer - II. Potassium ferrioxalate as a standard chemical actinometer
Hatchard, C. G., & Parker, C. A. (1956) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1956.0102 · Cited by 2,935
(2007) · Choice Reviews Online · doi:10.5860/choice.44-4456 · Cited by 2,078
Dürr, H. (1994) · Synthesis · doi:10.1055/s-1994-25560 · Cited by 1,944
Quantities, units and symbols in physical chemistry
Renner, T. (2007) · Royal Society of Chemistry eBooks · doi:10.1039/9781847557889 · Cited by 1,276
Standardization of Methods for Fluence (UV Dose) Determination in Bench-Scale UV Experiments
Bolton, J. R., & Linden, K. G. (2003) · Journal of Environmental Engineering · doi:10.1061/(asce)0733-9372(2003)129:3(209 · Cited by 1,215
Self-citationChemical actinometry (IUPAC Technical Report)
Kuhn, H. J., Braslavsky, S. E., & Schmidt, R. (2004) · Pure and Applied Chemistry · doi:10.1351/pac200476122105 · Cited by 875
Tanaka, M., Girard, G., Davis, R., Peuto, A., & Bignell, N. (2001) · Metrologia · doi:10.1088/0026-1394/38/4/3 · Cited by 420
Rahn, R. O. (1997) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1997.tb03172.x · Cited by 369
Quantum Yield of the Iodide-Iodate Chemical Actinometer: Dependence on Wavelength and Concentration¶
Rahn, R. O., Stefan, M. I., Bolton, J. R., Goren, E., Shaw, P.-S., & Lykke, K. R. (2007) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2003)0780146qyotic2.0.co2 · Cited by 242
Self-citationThe ferrioxalate and iodide–iodate actinometers in the UV region
Goldstein, S., & Rabani, J. (2008) · Journal of Photochemistry and Photobiology A: Chemistry · doi:10.1016/j.jphotochem.2007.06.006 · Cited by 232
Cited by
The Roles of Reactive Species in Micropollutant Degradation in the UV/Free Chlorine System
Fang, J., Fu, Y., & Shang, C. (2014) · Environmental Science & Technology · doi:10.1021/es4036094 · Cited by 1,031
Wang, W.-L., Wu, Q.-Y., Huang, N., Wang, T., & Hu, H.-Y. (2016) · Water Research · doi:10.1016/j.watres.2016.04.015 · Cited by 449
Chuang, Y.-H., Chen, S., Chinn, C. J., & Mitch, W. A. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b03570 · Cited by 441
Lee, C.-G., Javed, H., Zhang, D., Kim, J.-H., Westerhoff, P., Li, Q., & Alvarez, P. J. J. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.7b06508 · Cited by 350
Wu, Z., Fang, J., Xiang, Y., Shang, C., Li, X., Meng, F., & Yang, X. (2016) · Water Research · doi:10.1016/j.watres.2016.08.011 · Cited by 349
Metadata
- Authors
- Bolton, J. R., Stefan, M. I., Shaw, P.-S., & Lykke, K. R.
- Venue
- Journal of Photochemistry and Photobiology A: Chemistry
- Publisher
- Elsevier BV
- Published
- 2011-07
- Volume
- 222
- Issue
- 1
- Pages
- 166-169
- ISSN
- 1010-6030 (ISSN-L)
- OpenAlex
- W1991390421
- Cited by
- 308
- References
- 11
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of the quantum yields of the potassium ferrioxalate and potassium iodide–iodate actinometers and a method for the calibration of radiometer detectors. https://app.cochat.ai/papers/10.1016/j.jphotochem.2011.05.017
- The paper
- Bolton, J. R., Stefan, M. I., Shaw, P.-S., & Lykke, K. R. (2011). Determination of the quantum yields of the potassium ferrioxalate and potassium iodide–iodate actinometers and a method for the calibration of radiometer detectors. Journal of Photochemistry and Photobiology A: Chemistry. https://doi.org/10.1016/j.jphotochem.2011.05.017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.