The DOI matches its Crossref record.
Potassium Iodide as a Chemical Actinometer for 254 nm Radiation: Use of lodate as an Electron Scavenger
Abstract
Abstract— A solution of 0.6 M iodide and 0.1 M iodate in 0.01 M borate buffer (pH 9.25) can be used as a chemical actinometer to measure the incident fluence from a low‐pressure mercury lamp that puts out more than 85% of its energy at 254 nm. The actinometric solution is optically opaque to light below 290 nm and is optically transparent to wavelengths greater than 330 nm. Hence, the solution absorbs all of the germicidal wavelengths but little if any of the ambient light normally present in the laboratory. Iodate acts as an electron scavenger and prevents the back reaction of the free electron with the iodine atom following UV excitation of KI. Irradiation results in the linear formation of triiodide, which is quantitated by measuring its absorbance at 352 nm. The quantum yield for this system is approximately 0.75 0.03 at 20.7A o C or approximately three times greater than that obtained previously using nitrous oxide as an electron scavenger. A model is proposed to account for this difference. A precise expression to account for the concentration and temperature dependence of the quantum yield is given by pH = 0.75(1 + 0.23[C ‐ 0.577])(1 + 0.02[T ‐ 20.7]) where C is the concentration of iodide and T is the temperature. The concentration of iodide can be obtained from the absorbance at 300 nm prior to irradiation using 1.061 MJ cm−1 as the molar extinction coefficient. This actinometric system meets the quality criteria established by the International Union of Pure and Applied Chemistry with the caveat that it is designed to measure only germicidal radiation (i.e. wavelengths less than 290 nm).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gao, J., Duan, X., O’Shea, K., & Dionysiou, D. D. (2020) · Water Research · doi:10.1016/j.watres.2019.115394 · Cited by 325
Li, G.-Q., Wang, W.-L., Huo, Z.-Y., Lu, Y., & Hu, H.-Y. (2017) · Water Research · doi:10.1016/j.watres.2017.09.030 · Cited by 305
Microbial UV fluence-response assessment using a novel UV-LED collimated beam system
Bowker, C., Sain, A., Shatalov, M., & Ducoste, J. (2011) · Water Research · doi:10.1016/j.watres.2010.12.005 · Cited by 192
Gilboa, Y., & Friedler, E. (2008) · Water Research · doi:10.1016/j.watres.2007.09.027 · Cited by 130
Kinetics and mechanisms of pH-dependent degradation of halonitromethanes by UV photolysis
Fang, J.-Y., Ling, L., & Shang, C. (2013) · Water Research · doi:10.1016/j.watres.2012.11.050 · Cited by 88
Metadata
- Authors
- Rahn, R. O.
- Venue
- Photochemistry and Photobiology
- Publisher
- Wiley
- Published
- 1997-10
- Volume
- 66
- Issue
- 4
- Pages
- 450-455
- ISSN
- 0031-8655 (ISSN-L)
- 1751-1097
- OpenAlex
- W1998321738
- Cited by
- 369
- References
- 0
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Potassium Iodide as a Chemical Actinometer for 254 nm Radiation: Use of lodate as an Electron Scavenger. https://app.cochat.ai/papers/10.1111/j.1751-1097.1997.tb03172.x
- The paper
- Rahn, R. O. (1997). Potassium Iodide as a Chemical Actinometer for 254 nm Radiation: Use of lodate as an Electron Scavenger. Photochemistry and Photobiology. https://doi.org/10.1111/j.1751-1097.1997.tb03172.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.