CoChat

A comparison of rotating disc electrode, floating electrode technique and membrane electrode assembly measurements for catalyst testing

Open access
Martens, Sladjana, Asen, Ludwig, Ercolano, Giorgio, Dionigi, Fabio, Zalitis, Chris, Hawkins, Alex, Martinez Bonastre, Alejandro, Seidl, Lukas, Knoll, Alois C., Sharman, Jonathan, Strasser, Peter, Jones, Deborah, Schneider, Oliver · 2018 · Journal of Power Sources
Cited by 120

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The development of new catalysts for low temperature fuel cells requires accurate characterization techniques to evaluate their performance. As initially only small amounts of catalyst are available, preliminary screening must rely on suitable test methods. In this work, using a carbon supported platinum benchmark catalyst, the rotating disc electrode (RDE) technique was revisited in order to develop a detailed testing protocol leading to comparable results between different laboratories. The RDE results were validated by comparison with data measured both in proton exchange membrane single cells and via the relatively new floating electrode technique. This method can be operated with small amounts of catalyst but does not suffer from low limiting currents and allows prediction of high current capability of newly developed catalysts. Different durability testing protocols were tested with all three methods. Such protocols need to be able to introduce changes in the reference catalyst, but must not be too harsh as otherwise they cannot be applied to alloy catalysts. In all protocols an upper potential limit of 0.925 V was used, as this produced degradation in the chosen benchmark catalyst, but still represents realistic conditions for alloy catalysts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jpowsour.2018.04.084

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 120

Metadata

Authors
Martens, S., Asen, L., Ercolano, G., Dionigi, F., Zalitis, C., Hawkins, A., Martinez Bonastre, A., Seidl, L., Knoll, A. C., Sharman, J., Strasser, P., Jones, D., & Schneider, O.
Venue
Journal of Power Sources
Publisher
Elsevier BV
Published
2018-07
Volume
392
Pages
274-284
ISSN
0378-7753 (ISSN-L)
OpenAlex
W2804150812
Cited by
120
References
7
FWCI
4.99
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of rotating disc electrode, floating electrode technique and membrane electrode assembly measurements for catalyst testing. https://app.cochat.ai/papers/10.1016/j.jpowsour.2018.04.084
The paper
Martens, S., Asen, L., Ercolano, G., Dionigi, F., Zalitis, C., Hawkins, A., Martinez Bonastre, A., Seidl, L., Knoll, A. C., Sharman, J., Strasser, P., Jones, D., & Schneider, O. (2018). A comparison of rotating disc electrode, floating electrode technique and membrane electrode assembly measurements for catalyst testing. Journal of Power Sources. https://doi.org/10.1016/j.jpowsour.2018.04.084

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.