The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Advanced impedance study of polymer electrolyte membrane single cells by means of distribution of relaxation times
Abstract
Abstract Electrochemical impedance spectroscopy data of a polymer electrolyte membrane fuel cell are compiled across a wide range of operating conditions. In all cases, homogeneous operating conditions are applied over the entire cell area to set a clearly defined operating point and to derive unambiguous parameter dependencies. As a novelty, this diverse set of impedance spectra is deconvoluted by the distribution of relaxation times (DRT) method in the frequency range from 0.5 Hz to 60 kHz. In H2/air-operation five polarization contributions with different time constants are registered. The assignment to gas diffusion in the gas diffusion layer and catalyst layer, the oxygen reduction reaction at the Pt-catalyst and proton transport processes in the cathode catalyst layer is supported by a systematic analysis of parameter dependencies. Furthermore, DRT deconvolution in H2/H2-operation reveals three “new” anode contributions, usually hidden by the dominating cathode contributions. They are assigned to gas diffusion and hydrogen oxidation, including charge-transfer and proton transport in the anode catalyst layer. It is confirmed that the polarization contributions at the cathode side sum up to 96% for typical operating conditions, but the share changes to 80% cathode and 20% anode at low hydrogen partial pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymer Electrolyte Fuel Cell Model
Springer, T. E., Zawodzinski, T. A., & Gottesfeld, S. (1991) · Journal of The Electrochemical Society · doi:10.1149/1.2085971 · Cited by 3,528
Numerical Methods for the Solution of Ill-Posed Problems
Tikhonov, A. N., Goncharsky, A. V., Stepanov, V. V., & Yagola, A. G. (1995) · doi:10.1007/978-94-015-8480-7 · Cited by 1,819
Modeling Transport in Polymer-Electrolyte Fuel Cells
Weber, A. Z., & Newman, J. (2004) · Chemical Reviews · doi:10.1021/cr020729l · Cited by 738
Self-citationA Multi‐Scale Dynamic Mechanistic Model for the Transient Analysis of PEFCs
Franco, A. A., Schott, P., Jallut, C., & Maschke, B. (2007) · Fuel Cells · doi:10.1002/fuce.200500204 · Cited by 119
Cited by
Techno-economic assessment of low-temperature carbon dioxide electrolysis
Shin, H., Hansen, K. U., & Jiao, F. (2021) · Nature Sustainability · doi:10.1038/s41893-021-00739-x · Cited by 741
Maradesa, A., Py, B., Huang, J., Lu, Y., Iurilli, P., Mrozinski, A., Law, H. M., Wang, Y., Wang, Z., Li, J., et al. (2024) · Joule · doi:10.1016/j.joule.2024.05.008 · Cited by 457
Self-citationPlank, C., Rüther, T., Jahn, L., Schamel, M., Schmidt, J. P., Ciucci, F., & Danzer, M. A. (2024) · Journal of Power Sources · doi:10.1016/j.jpowsour.2023.233845 · Cited by 314
How the distribution of relaxation times enhances complex equivalent circuit models for fuel cells
Dierickx, S., Weber, A., & Ivers-Tiffée, E. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.136764 · Cited by 281
Self-citationTang, Z., Huang, Q.-A., Wang, Y.-J., Zhang, F., Li, W., Li, A., Zhang, L., & Zhang, J. (2020) · Journal of Power Sources · doi:10.1016/j.jpowsour.2020.228361 · Cited by 276
Metadata
- Authors
- Heinzmann, M., Weber, A., & Ivers-Tiffée, E.
- Venue
- Journal of Power Sources
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 402
- Pages
- 24-33
- ISSN
- 0378-7753 (ISSN-L)
- OpenAlex
- W2891143741
- Cited by
- 243
- References
- 4
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advanced impedance study of polymer electrolyte membrane single cells by means of distribution of relaxation times. https://app.cochat.ai/papers/10.1016/j.jpowsour.2018.09.004
- The paper
- Heinzmann, M., Weber, A., & Ivers-Tiffée, E. (2018). Advanced impedance study of polymer electrolyte membrane single cells by means of distribution of relaxation times. Journal of Power Sources. https://doi.org/10.1016/j.jpowsour.2018.09.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.