The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
In-situ measurement of temperature and humidity distribution in gas channels for commercial-size proton exchange membrane fuel cells
Abstract
Abstract It is necessary to obtain internal heat and water distribution of proton exchange membrane fuel cells in order to perform water-heat management. Most of the existing works focus on the measurement in small experimental fuel cells, which cannot effectively guide the development of large-area fuel cells. In this study, an in-situ measurement method using micro-sensors is developed to observe the temperature and relative humidity in a commercial-size fuel cell with parallel flow fields and an active area of 250 cm2. A sensor array is incorporated into the cathode flow field, and well-designed waterproof and sealing structures protect sensors from liquid water. The sensors are verified with accuracy and response speed. The fuel cell performance and electrochemical impedance spectroscopy under co-flow and counter-flow configurations considering anode gas humidification are investigated. The results show that the temperature distribution is more uneven in the cases with lower output voltage, and the fuel cell performance is significantly affected by the humidity near the air inlet area. As current density increases, the relative humidity drops while dew point temperature keeps almost unchanged. The experimental method and analysis are beneficial to the understanding of the water-heat state and optimization of fuel cell stack design.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, the GDL on the cathode needs to be more hydrophobic than that near the anode [121,122].”
From Recent Advances on PEM Fuel Cells: From Key Materials to Membrane Electrode Assembly (2023) · cites this paper as [121]
Citations
Cites
Fundamental Models for Fuel Cell Engineering
Wang, C.-Y. (2004) · Chemical Reviews · doi:10.1021/cr020718s · Cited by 1,266
Mench, M. M. (2008) · Wiley eBooks · doi:10.1002/9780470209769 · Cited by 698
Satija, R., Jacobson, D. L., Arif, M., & Werner, S. A. (2004) · Journal of Power Sources · doi:10.1016/j.jpowsour.2003.11.068 · Cited by 468
Visualization and quantification of cathode channel flooding in PEM fuel cells
Hussaini, I., & Wang, C. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.11.030 · Cited by 314
Liu, X., Guo, H., Ye, F., & Ma, C. F. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.10.030 · Cited by 188
Yan, X. C., Hou, M., Sun, L., LIANG, D., SHEN, Q., Xu, H., Ming, P., & Yi, B. (2007) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2007.06.024 · Cited by 180
Lee, J., Hinebaugh, J., & Bazylak, A. (2012) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.11.006 · Cited by 165
He, S., Mench, M. M., & Tadigadapa, S. A. (2005) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2005.05.021 · Cited by 114
Bi, F., Yi, P., Zhou, T., Peng, L., & Lai, X. (2015) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2015.06.012 · Cited by 113
Self-citationYi, P., Zhang, W., Bi, F., Peng, L., & Lai, X. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b00514 · Cited by 83
Self-citation
Cited by
Recent Advances on PEM Fuel Cells: From Key Materials to Membrane Electrode Assembly
Mo, S., Du, L., Huang, Z., Chen, J., Zhou, Y., Wu, P., Meng, L., Wang, N., Xing, L., Zhao, M., et al. (2023) · Electrochemical Energy Reviews · doi:10.1007/s41918-023-00190-w · Cited by 277
“Therefore, the GDL on the cathode needs to be more hydrophobic than that near the anode [121, 122].”
A review of proton exchange membrane fuel cell water management: Membrane electrode assembly
Liu, Q., Lan, F., Chen, J., Zeng, C., & Wang, J. (2022) · Journal of Power Sources · doi:10.1016/j.jpowsour.2021.230723 · Cited by 200
Shao, H., Qiu, D., Peng, L., Yi, P., & Lai, X. (2019) · Renewable Energy · doi:10.1016/j.renene.2019.02.028 · Cited by 48
Self-citation
Metadata
- Authors
- Shao, H., Qiu, D., Peng, L., Yi, P., & Lai, X.
- Affiliations
- Shanghai Jiao Tong University (CN)
- Corresponding author
- Lai, Xinmin
- Venue
- Journal of Power Sources
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 412
- Pages
- 717-724
- ISSN
- 0378-7753 (ISSN-L)
- OpenAlex
- W2903983544
- Cited by
- 85
- References
- 29
- Citations by year
- 2026: 8 · 2025: 10 · 2024: 17 · 2023: 8 · 2022: 11 · 2021: 13 · 2020: 13 · 2019: 5
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Power Sources (publishedVersion)
- Funders
- National Natural Science Foundation of China (51705308)
- National Basic Research Program of China (2017YFB0102900)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Fuel Cells and Related Materials
- Physical Sciences › Materials Science › Materials Chemistry › Advancements in Solid Oxide Fuel Cells
- Physical Sciences › Engineering › Automotive Engineering › Electric and Hybrid Vehicle Technologies
- Keywords
- proton exchange membrane fuel cells, in-situ temperature measurement, relative humidity distribution, gas channels, cathode flow field, parallel flow field, dew point, large-area fuel cells, fuel cell stack design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-situ measurement of temperature and humidity distribution in gas channels for commercial-size proton exchange membrane fuel cells. https://app.cochat.ai/papers/10.1016/j.jpowsour.2018.12.008
- The paper
- Shao, H., Qiu, D., Peng, L., Yi, P., & Lai, X. (2019). In-situ measurement of temperature and humidity distribution in gas channels for commercial-size proton exchange membrane fuel cells. Journal of Power Sources. https://doi.org/10.1016/j.jpowsour.2018.12.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.