The DOI matches its Crossref record.
Semi-automated selection of cryo-EM particles in RELION-1.3
Open accessAbstract
The selection of particles suitable for high-resolution cryo-EM structure determination from noisy micrographs may represent a tedious and time-consuming step. Here, a semi-automated particle selection procedure is presented that has been implemented within the open-source software RELION. At the heart of the procedure lies a fully CTF-corrected template-based picking algorithm, which is supplemented by a fast sorting algorithm and reference-free 2D class averaging to remove false positives. With only limited user-interaction, the proposed procedure yields results that are comparable to manual particle selection. Together with an improved graphical user interface, these developments further contribute to turning RELION from a stand-alone refinement program into a convenient image processing pipeline for the entire single-particle approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 39
- Allegretti, 2014, Atomic model of the f420-reducing [NiFe] hydrogenase by electron cryo-microscopy using a direct electron detector, eLife, 3, 10.7554/eLife.01963 · DOI
- Amunts, 2014, Structure of the yeast mitochondrial large ribosomal subunit, Science, 343, 1485, 10.1126/science.1249410 · DOI · Paper page
- Bai, 2013, Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles, eLife, 2, e00461, 10.7554/eLife.00461 · DOI
- Campbell, 2012, Movies of ice-embedded particles enhance resolution in electron cryo-microscopy, Structure, 20, 1823, 10.1016/j.str.2012.08.026 · DOI · Paper page
- Cao, 2013, TRPV1 structures in distinct conformations reveal activation mechanisms, Nature, 504, 113, 10.1038/nature12823 · DOI
- Chen, 2007, SIGNATURE: a single-particle selection system for molecular electron microscopy, J. Struct. Biol., 157, 168, 10.1016/j.jsb.2006.06.001 · DOI
- Chen, 2013, High-resolution noise substitution to measure overfitting and validate resolution in 3d structure determination by single particle electron cryomicroscopy, Ultramicroscopy, 135, 24, 10.1016/j.ultramic.2013.06.004 · DOI
- Dugdale, 2010, Role of met-542 as a guide for the conformational changes of phe-601 that occur during the reaction of β-galactosidase (Escherichia coli), Biochem. Cell Biol., 88, 861, 10.1139/O10-009 · DOI
- Fernndez, 2013, Molecular architecture of a eukaryotic translational initiation complex, Science (New York, N.Y.), 342, 1240585, 10.1126/science.1240585 · DOI
- Grigorieff, 2011, Near-atomic resolution reconstructions of icosahedral viruses from electron cryo-microscopy, Curr. Opin. Struct. Biol., 21, 265, 10.1016/j.sbi.2011.01.008 · DOI
- Hall, 1991, The STAR file: a new format for electronic data transfer and archiving, J. Chem. Inf. Comput. Sci., 31, 326, 10.1021/ci00002a020 · DOI
- Henderson, 2013, Avoiding the pitfalls of single particle cryo-electron microscopy: Einstein from noise, Proc. Natl. Acad. Sci. USA, 110, 18037, 10.1073/pnas.1314449110 · DOI
- Kucukelbir, 2014, Quantifying the local resolution of cryo-EM density maps, Nat. Methods, 11, 63, 10.1038/nmeth.2727 · DOI
- Langlois, 2011, A clarification of the terms used in comparing semi-automated particle selection algorithms in cryo-EM, J. Struct. Biol., 175, 348, 10.1016/j.jsb.2011.03.009 · DOI
- Langlois, 2014, Automated particle picking for low-contrast macromolecules in cryo-electron microscopy, J. Struct. Biol., 186, 1, 10.1016/j.jsb.2014.03.001 · DOI
- Li, 2013, Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM, Nat. Methods, 10, 584, 10.1038/nmeth.2472 · DOI
- Lu, 2014, Three-dimensional structure of human-secretase, Nature, 512, 166, 10.1038/nature13567 · DOI
- McMullan, 2009, Detective quantum efficiency of electron area detectors in electron microscopy, Ultramicroscopy, 109, 1126, 10.1016/j.ultramic.2009.04.002 · DOI
- Mindell, 2003, Accurate determination of local defocus and specimen tilt in electron microscopy, J. Struct. Biol., 142, 334, 10.1016/S1047-8477(03)00069-8 · DOI
- Nicholson, 2001, Review: automatic particle detection in electron microscopy, J. Struct. Biol., 133, 90, 10.1006/jsbi.2001.4348 · DOI
- Roseman, 2003, Particle finding in electron micrographs using a fast local correlation algorithm, Ultramicroscopy, 94, 225, 10.1016/S0304-3991(02)00333-9 · DOI
- Roseman, 2004, FindEM – a fast, efficient program for automatic selection of particles from electron micrographs, J. Struct. Biol., 145, 91, 10.1016/j.jsb.2003.11.007 · DOI
- Scheres, 2014, Beam-induced motion correction for sub-megadalton cryo-EM particles, eLife, 3, e03665, 10.7554/eLife.03665 · DOI
- Scheres, 2010, Classification of structural heterogeneity by maximum-likelihood methods, vol. 482, 295
- Scheres, 2012, A bayesian view on cryo-EM structure determination, J. Mol. Biol., 415, 406, 10.1016/j.jmb.2011.11.010 · DOI · Paper page
- Scheres, 2012, RELION: implementation of a bayesian approach to cryo-EM structure determination, J. Struct. Biol., 180, 519, 10.1016/j.jsb.2012.09.006 · DOI · Paper page
- Scheres, 2012, Prevention of overfitting in cryo-EM structure determination, Nat. Methods, 9, 853, 10.1038/nmeth.2115 · DOI · Paper page
- Scheres, 2007, Disentangling conformational states of macromolecules in 3d-EM through likelihood optimization, Nat. Methods, 4, 27, 10.1038/nmeth992 · DOI
- Shatsky, 2009, A method for the alignment of heterogeneous macromolecules from electron microscopy, J. Struct. Biol., 166, 67, 10.1016/j.jsb.2008.12.008 · DOI
- Sorzano, 2004, Normalizing projection images: a study of image normalizing procedures for single particle three-dimensional electron microscopy, Ultramicroscopy, 101, 129, 10.1016/j.ultramic.2004.04.004 · DOI
- Sorzano, 2009, Automatic particle selection from electron micrographs using machine learning techniques, J. Struct. Biol., 167, 252, 10.1016/j.jsb.2009.06.011 · DOI
- Suloway, 2005, Automated molecular microscopy: the new leginon system, J. Struct. Biol., 151, 41, 10.1016/j.jsb.2005.03.010 · DOI · Paper page
- Tang, 2007, EMAN2: an extensible image processing suite for electron microscopy, J. Struct. Biol., 157, 38, 10.1016/j.jsb.2006.05.009 · DOI
- van Heel, 2013, Finding trimeric HIV-1 envelope glycoproteins in random noise, Proc. Natl. Acad. Sci. USA, 110, E4175, 10.1073/pnas.1314353110 · DOI
- Vinothkumar, 2014, Molecular mechanism of antibody-mediated activation of galactosidase, Structure, 22, 621, 10.1016/j.str.2014.01.011 · DOI
- Voorhees, 2014, Structure of the mammalian ribosome-Sec61 complex to 3.4 resolution, Cell, 157, 1632, 10.1016/j.cell.2014.05.024 · DOI
- Voss, 2009, DoG picker and TiltPicker: software tools to facilitate particle selection in single particle electron microscopy, J. Struct. Biol., 166, 205, 10.1016/j.jsb.2009.01.004 · DOI
- Wong, 2014, Cryo-EM structure of the Plasmodium falciparum 80s ribosome bound to the anti-protozoan drug emetine, eLife, e03080, 10.7554/eLife.03080 · DOI · Paper page
- Zhu, 2004, Automatic particle selection: results of a comparative study, J. Struct. Biol., 145, 3, 10.1016/j.jsb.2003.09.033 · DOI
Cited by
Opportunities and obstacles for deep learning in biology and medicine
Ching, T., Himmelstein, D. S., Beaulieu-Jones, B. K., Kalinin, A. A., Do, B. T., Way, G. P., Ferrero, E., Agapow, P.-M., Zietz, M., Hoffman, M. M., et al. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0387 · Cited by 2,310
EMRinger: side chain–directed model and map validation for 3D cryo-electron microscopy
Barad, B. A., Echols, N., Wang, R. Y.-R., Cheng, Y., DiMaio, F., Adams, P. D., & Fraser, J. S. (2015) · Nature Methods · doi:10.1038/nmeth.3541 · Cited by 886
Structure of the human LAT1–4F2hc heteromeric amino acid transporter complex
Yan, R., Zhao, X., Lei, J., & Zhou, Q. (2019) · Nature · doi:10.1038/s41586-019-1011-z · Cited by 358
Recognition of the amyloid precursor protein by human γ-secretase
Zhou, R., Yang, G., Guo, X., Zhou, Q., Lei, J., & Shi, Y. (2019) · Science · doi:10.1126/science.aaw0930 · Cited by 304
Molecular mechanism of APC/C activation by mitotic phosphorylation
Zhang, S., Chang, L., Alfieri, C., Zhang, Z., Yang, J., Maslen, S., Skehel, M., & Barford, D. (2016) · Nature · doi:10.1038/nature17973 · Cited by 203
Metadata
- Authors
- Scheres, S. H. W.
- Venue
- Journal of Structural Biology
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 189
- Issue
- 2
- Pages
- 114-122
- ISSN
- 1047-8477 (ISSN-L)
- OpenAlex
- W1982295411
- Cited by
- 377
- References
- 0
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Funders
- UK Medical Research Council (MC_UP_A025_1013)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Semi-automated selection of cryo-EM particles in RELION-1.3. https://app.cochat.ai/papers/10.1016/j.jsb.2014.11.010
- The paper
- Scheres, S. H. W. (2015). Semi-automated selection of cryo-EM particles in RELION-1.3. Journal of Structural Biology. https://doi.org/10.1016/j.jsb.2014.11.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.