CoChat

Performance of LC–MS/MS and immunoassay based 24-h urine free cortisol in the diagnosis of Cushing's syndrome

Oßwald, Andrea, Wang, Rong, Beuschlein, Felix, Hartmann, Michaela F., Wudy, Stefan A., Bidlingmaier, Martin, Zopp, Stephanie, Reincke, Martin, Ritzel, Katrin · 2019 · The Journal of Steroid Biochemistry and Molecular Biology
Cited by 43

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

24-h urine free cortisol (UFC) is an indicator of integrated cortisol secretion and established screening tool for Cushing's syndrome (CS). Doubts have been raised regarding specificity of immunoassays, and mass spectrometric techniques have been proposed as an alternative. In the present study we compared diagnostic accuracy of UFC measured with LC-MS/MS vs. immunoassay in patient with CS and patients where CS has been excluded. We examined 24-h urine samples from patients with surgically confirmed CS (n = 77; Cushing's disease (n = 44), ectopic CS (n = 5), adrenal CS (n = 28)) and patients in whom Cushing's syndrome was excluded (n = 97) by long-term follow up. UFC was first measured by automated chemiluminescence immunoassays (ADVIA Centaur, Siemens; LIAISON, DiaSorin). Aliquots of all samples were also analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Statistics: Passing-Bablok Regression, Receiver operating characteristic (ROC) analysis with Youden's index calculation. UFC of CS patients were higher with both immunoassays compared to LC-MS/MS (913 +/- 235 vs. 303 +/- 155 μg/24 h (ADVIA) and 898 +/-216 vs. 399 +/- 196 μg/24 h (LIAISON)). Similarly, UFC were higher with immunoassays than with LC-MS/MS in the control group (223 +/- 10 vs. 23 +/- 2 μg/24 h (ADVIA) and 105 +/- 6 vs. 27 +/- 4 ug/24 h for (LIAISON)). Passing-Bablok regression showed good correlation between LC-MS/MS and ADVIA as well as between LCMS/MS and LIAISON (r = 0.96 and r = 0.99, p < 000.1) but less correlation in controls (r = 0.83 and r = 0.74, respectively, p < 000.1). ROC calculation revealed the highest ROC AUC (0.89) for the LIAISON immunoassay, followed by LC-MS/MS (0.82) and the ADVIA (0.80). In direct comparison, AUCs from LC-MS/MS and immunoassays in the same patient were not statistically different (p < 0,001). Best cut-off concentration to identify patients with CS was 234 μg/24 h (LIAISON), 51 μg/24 h for LC-MS/MS and 330 μg/24 h (ADVIA Centaur). In summary, UFC values were measured substantially higher by both immunoassays compared to LC-MS/MS. This is most likely due to cross-reactivity from interfering glucocorticoid metabolites. Nevertheless, all three methods correlated well. ROC analysis revealed the highest AUC for one of the immunoassays, although differences between the three methods were not significant. Direct comparison with LC-MS/MS indicates that high diagnostic accuracy can be obtained with suitable immunoassays.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jsbmb.2019.04.004

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Oßwald, A., Wang, R., Beuschlein, F., Hartmann, M. F., Wudy, S. A., Bidlingmaier, M., Zopp, S., Reincke, M., & Ritzel, K.
Venue
The Journal of Steroid Biochemistry and Molecular Biology
Publisher
Elsevier BV
Published
2019-06
Volume
190
Pages
193-197
ISSN
0960-0760 (ISSN-L)
OpenAlex
W2933537402
Cited by
43
References
8
FWCI
3.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.