Abstract

Introduction Colonoscopic simulators offer the opportunity for skill acquisition in the preclinical setting. Currently available simulators vary widely with respect to level of fidelity and technological sophistication. Despite the belief that more realistic is better, there is a paucity of evidence regarding the relative effectiveness of simulator fidelity (high vs low) on the acquisition of basic colonoscopic skills. We hypothesized that novice learners can acquire basic colonoscopic skills using simulators, however fidelity of the simulator does not make a difference. Methods We randomly assigned novice third-year and fourth-year medical students to practice on either a low-fidelity or high-fidelity colonoscopy model. The low-fidelity model used is described in the module 16 of the American College of Surgeons/Association of Program Directors in Surgery surgical skills curriculum for residents, Phase 1: basic or core skills and tasks . The high-fidelity model was the AccuTouch colonoscopy simulator, Immersion Medical (AccuTouch CS) that has 6 different simulated scenarios for diagnostic colonoscopy (level 1-6). Both groups had 16 students and were given standard instruction by an expert with respect to the procedure and instrument handling on both models. Both groups were pretested and posttested on level 1 of the AccuTouch CS. The high-fidelity group practiced on level 2 and 4 of the AccuTouch CS, whereas the low-fidelity group practiced on the low-fidelity model for 2 se…

Overview

Integrity signals

Registry

Crossref · 10.1016/j.jsurg.2013.02.010

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 1 references

Research works printed but not linked: 24

  1. Scott, 2008, The new ACS/APDS skills curriculum: moving the learning curve out of the operating room, J Gastrointest Surg, 12, 213, 10.1007/s11605-007-0357-y · DOI · Paper page
  2. Buzink, 2007, Acquiring basic endoscopy skills by training on the GI mentor II, Surg Endosc, 21, 1996, 10.1007/s00464-007-9297-6 · DOI
  3. Issenberg, 2008, Simulation in health care education, Perspect Biol Med, 51, 31, 10.1353/pbm.2008.0004 · DOI · Paper page
  4. Wilson, 2005, Assessment of a low-fidelity human patient simulator for the acquisition of nursing skills, Nurse Educ Today, 25, 56, 10.1016/j.nedt.2004.10.004 · DOI
  5. Sedlack, 2002, Colonoscopy curriculum development and performance-based assessment criteria on a computer-based endoscopy simulator, Acad Med, 77, 750, 10.1097/00001888-200207000-00041 · doi:10.1097/00001888-200207000-00041
  6. Sedlack, 2004, Computer simulator training enhances the competency of gastroenterology fellows at colonoscopy: results of a pilot study, Am J Gastroenterol, 99, 33, 10.1111/j.1572-0241.2004.04007.x · DOI · Paper page
  7. Cohen, 2006, Multicenter, randomized, controlled trial of virtual-reality simulator training in acquisition of competency in colonoscopy, Gastrointest Endosc, 64, 361, 10.1016/j.gie.2005.11.062 · DOI · Paper page
  8. Park, 2007, Randomized controlled trial of virtual reality simulator training: transfer to live patients, Am J Surg, 194, 205, 10.1016/j.amjsurg.2006.11.032 · DOI · Paper page
  9. Matsumoto, 2002, The effect of bench model fidelity on endourological skills: a randomized controlled study, J Urol, 167, 1243, 10.1016/S0022-5347(05)65274-3 · DOI · Paper page
  10. Chandra, 2008, Fiberoptic oral intubation: the effect of model fidelity on training for transfer to patient care, Anesthesiology, 109, 1007, 10.1097/ALN.0b013e31818d6c3c · DOI · Paper page
  11. Grober, 2004, The educational impact of bench model fidelity on the acquisition of technical skill: the use of clinically relevant outcome measures, Ann Surg, 240, 374, 10.1097/01.sla.0000133346.07434.30 · DOI · Paper page
  12. Koch, 2008, Expert and construct validity of the Simbionix GI mentor II endoscopy simulator for colonoscopy, Surg Endosc, 22, 158, 10.1007/s00464-007-9394-6 · DOI
  13. Ferlitsch, 2002, Evaluation of a virtual endoscopy simulator for training in gastrointestinal endoscopy, Endoscopy, 34, 698, 10.1055/s-2002-33456 · DOI · Paper page
  14. Felsher, 2005, Validation of a flexible endoscopy simulator, Am J Surg, 189, 497, 10.1016/j.amjsurg.2005.01.008 · DOI
  15. Datta, 2002, The PreOp flexible sigmoidoscopy trainer. Validation and early evaluation of a virtual reality based system, Surg Endosc, 16, 1459, 10.1007/s00464-002-9014-4 · DOI
  16. Mahmood, 2003, A study to validate the colonoscopy simulator, Surg Endosc, 17, 1583, 10.1007/s00464-002-9222-y · DOI
  17. Sedlack, 2003, Validation of a computer-based colonoscopy simulator, Gastrointest Endosc, 57, 214, 10.1067/mge.2003.81 · DOI
  18. Scott, 2000, Laparoscopic training on bench models: better and more cost effective than operating room experience?, J Am Coll Surg, 191, 272, 10.1016/S1072-7515(00)00339-2 · DOI · Paper page
  19. Naik, 2001, Fiberoptic orotracheal intubation on anesthetized patients: do manipulation skills learned on a simple model transfer into the operating room?, Anesthesiology, 95, 343, 10.1097/00000542-200108000-00014 · DOI · Paper page
  20. Alessi, 1988, Fidelity in the design of instructional simulations, J Comput Base Instr, 15, 40
  21. Dunkin, 2007, Surgical simulation: a current review, Surg Endosc, 21, 357, 10.1007/s00464-006-9072-0 · DOI · Paper page
  22. Gerson, 2006, Can colonoscopy simulators enhance the learning curve for trainees?, Gastrointest Endosc, 64, 369, 10.1016/j.gie.2006.02.010 · doi:10.1016/j.gie.2006.02.010
  23. Sidhu, 2007, Laboratory-based vascular anastomosis training: a randomized controlled trial evaluating the effects of bench model fidelity and level of training on skill acquisition, J Vasc Surg, 45, 343, 10.1016/j.jvs.2006.09.040 · DOI · Paper page
  24. Vassiliou, 2010, FLS and FES: comprehensive models of training and assessment, Surg Clin North Am, 90, 535, 10.1016/j.suc.2010.02.012 · DOI · Paper page

Cited by

Metadata

Authors
Ahad, S., Boehler, M., Schwind, C. J., & Hassan, I.
Venue
Journal of Surgical Education
Publisher
Elsevier BV
Published
2013-07
Volume
70
Issue
4
Pages
522-527
ISSN
1931-7204
Cited by
20
References
1
Language
en
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.