The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Initial center frequency-guided VMD for fault diagnosis of rotating machines
Abstract
Abstract Variational mode decomposition (VMD), an effective signal decomposing technique, has attracted considerable attention in recent years. The successful applicability of the VMD method mainly depends on the selection of decomposition parameters. Most of the existing VMD-like fault diagnostic methods only aim to optimize the number of either decomposed modes or balance parameters (or both) by adopting qualitative analysis, priori criteria, or genetic-like algorithms. However, the types of initial center frequencies (ICFs) in VMD are seldom discussed alongside the fault diagnosis of rotating machines. In actual scenarios, the selected ICFs have significant effects on the analytical results. Thus, in this study, the variation features of the center frequency (CF) of extracted modes are investigated with different ICFs, in which the converging U-shape phenomenon is found. Motived by this phenomenon, a novel ICF-guided VMD method is proposed to extract accurately the weak damage features of rotating machines. In particular, the proposed method is composed of two steps. First, an energy fluctuation spectrum is presented to rapidly highlight the ICF of the latent mode. Second, a CF-guided VMD optimization strategy is constructed to extract the optimal mode by adaptively refining the balance parameter. The simulations and experimental verifications confirm the effectiveness of the proposed method to enhance the fault diagnosis of rotating machines. A comparison with existing methods demonstrates the superiority of the proposed method to detect weak faults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lei, Y., Jia, F., Lin, J., Xing, S., & Ding, S. X. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2519325 · Cited by 1,191
Feng, Z., Liang, M., & Chu, F. (2013) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2013.01.017 · Cited by 998
Cited by
Feature Mode Decomposition: New Decomposition Theory for Rotating Machinery Fault Diagnosis
Miao, Y., Zhang, B., Li, C., Lin, J., & Zhang, D. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3156156 · Cited by 495
A systematic review of deep transfer learning for machinery fault diagnosis
Li, C., Zhang, S., Qin, Y., & Estupinan, E. (2020) · Neurocomputing · doi:10.1016/j.neucom.2020.04.045 · Cited by 472
Machinery fault diagnosis with imbalanced data using deep generative adversarial networks
Zhang, W., Li, X., Jia, X.-D., Ma, H., Luo, Z., & Li, X. (2020) · Measurement · doi:10.1016/j.measurement.2019.107377 · Cited by 364
The Entropy Algorithm and Its Variants in the Fault Diagnosis of Rotating Machinery: A Review
Li, Y., Wang, X., Liu, Z., Liang, X., & Si, S. (2018) · IEEE Access · doi:10.1109/access.2018.2873782 · Cited by 318
Han, T., Li, Y.-F., & Qian, M. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3088489 · Cited by 288
Metadata
- Authors
- Jiang, X., Shen, C., Shi, J., & Zhu, Z.
- Venue
- Journal of Sound and Vibration
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 435
- Pages
- 36-55
- ISSN
- 0022-460X (ISSN-L)
- OpenAlex
- W2886506350
- Cited by
- 203
- References
- 2
- FWCI
- 15.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.