CoChat

Efficacy of Combined Collagenase Clostridium histolyticum and RestoreX Penile Traction Therapy in Men with Peyronie’s Disease

Open access
Alom, Manaf, Sharma, Kiran L., Toussi, Amir, Kohler, Tobias, Trost, Landon · 2019 · The Journal of Sexual Medicine
Cited by 55

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Previous studies of penile traction therapy (PTT) devices have demonstrated limited/no efficacy when combined with intralesional therapies for Peyronie’s disease (PD). Recently, randomized data have demonstrated the efficacy of a novel PTT device, RestoreX, developed in cooperation with the Mayo Clinic, in men with PD. Aim: To assess the safety and efficacy of treatment with the RestoreX device plus collagenase Clostridium histolyticum (CCH) compared with CCH alone and CCH with other PTT devices. Methods: A prospective registry has been maintained of all men undergoing CCH injections for PD between March 2014 and January 2019. Assessments were performed at baseline, during each series, and after completion of treatment. Those completing therapy (8 injections or sooner if satisfied) were categorized into group 1 (CCH alone), group 2 (CCH plus any PTT device other than RestoreX), or group 3 (CCH plus RestoreX). Outcomes: Changes in penile length, curvature, and subjective perception and the occurrence of adverse events. Results: Of 287 men with data on PTT use, 113 had completed therapy with all objective data available and compose the current cohort. Baseline demographic and pathophysiological variables were similar among the 3 groups except penile length and previous PD medications. Following treatment, group 3 demonstrated significantly greater improvements in curvature (mean, 20.3°/31% for group 1, 19.2°/30% for group 2, and 33.8°/49% for group 3), length (-0.7 cm/-4%, -0.4 cm/-2%, and +1.9 cm/+17%, respectively), and subjectively estimated curvature improvement (44%, 32%, and 63% respectively), despite shorter daily PTT use (0.9 vs 1.9 hours/day). Group 3 was more likely than the other groups to experience ≥20°, ≥20%, and ≥50% curvature improvements, ≥1 cm length gain, and ≥20% length improvement. All results were statistically significant for group 3 versus groups 1 and 2, but not between groups 1 and 2, even after controlling for baseline features and isolating a subset of ≥3 hours/day PTT use (group 2). Group 3 was 6.9 times more likely to achieve ≥20° curvature improvement, and 3.5 times more likely to achieve ≥50% curvature improvement, and 10.7 times more likely to experience ≥20% length improvement. Adverse events were similar among the 3 groups. Clinical Implications: Use of the RestoreX device enhances mean curvature outcomes by 71% and increases penile length in men with PD receiving CCH therapy. Strengths & Limitations: Study strengths include a prospective registry, consistent assessments, the largest single-site series with complete posttreatment outcomes reported to date, the largest PTT series reported to date, and a true-to-life clinical design. Limitations include the nonrandomized methodology and single-site setting. Conclusion: The combination of RestoreX and CCH is associated with significantly greater curvature and length improvements compared with CCH alone or CCH with other PTT devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jsxm.2019.03.007

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 55

Metadata

Authors
Alom, M., Sharma, K. L., Toussi, A., Kohler, T., & Trost, L.
Venue
The Journal of Sexual Medicine
Published
2019-04-04
Volume
16
Issue
6
Pages
891-900
ISSN
  • 1743-6095 (ISSN-L)
  • 1743-6109
OpenAlex
W2933775013
Cited by
55
References
3
FWCI
8.43
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.