CoChat

Duration and magnitude of blood pressure below cerebral autoregulation threshold during cardiopulmonary bypass is associated with major morbidity and operative mortality

Open access
Ono, Masahiro, Brady, Kenneth, Easley, R. Blaine, Brown, Charles, Kraut, Michael, Gottesman, Rebecca F., Hogue, Charles W. · 2014 · The Journal of Thoracic and Cardiovascular Surgery
Cited by 231

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objectives Optimizing blood pressure using near-infrared spectroscopy monitoring has been suggested to ensure organ perfusion during cardiac surgery. Near-infrared spectroscopy is a reliable surrogate for cerebral blood flow in clinical cerebral autoregulation monitoring and might provide an earlier warning of malperfusion than indicators of cerebral ischemia. We hypothesized that blood pressure below the limits of cerebral autoregulation during cardiopulmonary bypass would be associated with major morbidity and operative mortality after cardiac surgery. Methods Autoregulation was monitored during cardiopulmonary bypass in 450 patients undergoing coronary artery bypass grafting and/or valve surgery. A continuous, moving Pearson’s correlation coefficient was calculated between the arterial pressure and low-frequency near-infrared spectroscopy signals and displayed continuously during surgery using a laptop computer. The area under the curve of the product of the duration and magnitude of blood pressure below the limits of autoregulation was compared between patients with and without major morbidity (eg, stroke, renal failure, mechanical lung ventilation >48 hours, inotrope use >24 hours, or intra-aortic balloon pump insertion) or operative mortality. Results Of the 450 patients, 83 experienced major morbidity or operative mortality. The area under the curve of the product of the duration and magnitude of blood pressure below the limits of autoregulation was independently associated with major morbidity or operative mortality after cardiac surgery (odds ratio, 1.36; 95% confidence interval, 1.08–1.71; P = .008). Conclusions Blood pressure management during cardiopulmonary bypass using physiologic endpoints such as cerebral autoregulation monitoring might provide a method of optimizing organ perfusion and improving patient outcomes from cardiac surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jtcvs.2013.07.069

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 231

Metadata

Authors
Ono, M., Brady, K., Easley, R. B., Brown, C., Kraut, M., Gottesman, R. F., & Hogue, C. W.
Venue
The Journal of Thoracic and Cardiovascular Surgery
Publisher
Elsevier BV
Published
2014-01
Volume
147
Issue
1
Pages
483-489
ISSN
0022-5223 (ISSN-L)
OpenAlex
W2131515788
Cited by
231
References
2
FWCI
15.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.