Predictors of low cardiac output syndrome after isolated aortic valve surgery

Open access
Maganti, Manjula D., Rao, Vivek, Borger, Michael A., Ivanov, Joan, David, Tirone E.·2005·Circulation

Abstract

BACKGROUND: Low cardiac output syndrome (LCOS), defined as the need for postoperative intraaortic balloon pump or inotropic support for >30 minutes in the intensive care unit, remains a relatively common complication of aortic valve (AV) surgery. The aim of this study is to identify the preoperative predictors of LCOS in patients undergoing isolated AV surgery. METHODS AND RESULTS: We conducted a retrospective review of data prospectively entered into an institutional database. Between 1990 and 2003, 2255 patients underwent isolated AV surgery with no other concomitant cardiac surgery. The independent predictors of LCOS and operative mortality (OM) were determined by stepwise logistic regression analysis. The overall prevalence of LCOS was 3.9%. The independent predictors of LCOS were (odds ratio in parentheses) renal failure (5.0), earlier year of operation (4.4), left ventricular ejection fraction <40% (3.6), shock (3.2), female gender (2.8), and increasing age (1.02). Overall OM was 2.9%. The OM was higher in patients who experienced LCOS (38% versus 1.5%; P<0.001). The independent predictors of mortality were (odds ratio in parentheses) preoperative renal failure (8.3), urgency of surgery (3.4), previous stroke (2.9), congestive heart failure (2.6), previous cardiac surgery (2.3), hypertension (1.7), and small AV size (1.3). CONCLUSIONS: Low-output syndrome is associated with significantly increased morbidity and mortality. Novel strategies to preserve renal function, optimization of preexisting heart failure symptoms, and avoidance of prosthesis-patient mismatch may reduce the incidence of LCOS and lead to improved results after AV surgery.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.526087

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. Rao V, Christakis GT, Weisel RD, Buth KJ, Ikonomidis JS, Shirai T, Cohen G, David TE. Changing pattern of valve surgery. Circu- lation. 1996;94:113-120.
  2. Hosmer DW, Lemeshow S. Applied logistic regression. New York: John Wiley and Sons; 1989.

Cited by

Sorted by citations

Authors
Maganti, M. D., Rao, V., Borger, M. A., Ivanov, J., & David, T. E.
Affiliations
University of Toronto (CA)
Venue
Circulation
Published
2005-08-30
Volume
112
Issue
9_supplement
Pages
I448-52
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1495427827
Cited by
143
References
22
Citations by year
2026: 4 · 2025: 3 · 2024: 4 · 2023: 19 · 2022: 8 · 2021: 5 · 2020: 12 · 2019: 11 · 2018: 3 · 2017: 8 · 2016: 3 · 2015: 7 · 2014: 9 · 2013: 7 · 2012: 9
FWCI
2.05
Type
journal article
Language
en
Open access
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Funders
Heart and Stroke Foundation of Canada
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Aortic Disease and Treatment Approaches
  • Health Sciences › Medicine › Surgery › Cardiac and Coronary Surgery Techniques
Keywords
low cardiac output syndrome, aortic valve surgery, isolated aortic valve replacement, postoperative complications, postoperative mortality, preoperative risk factors, renal failure, left ventricular ejection fraction, shock, prosthesis-patient mismatch, heart failure, intra-aortic balloon pump, inotropic support
MeSH terms
Aged, Aortic Valve, Cardiac Output, Low, Cardiotonic Agents, Critical Care, Female, Humans, Intra-Aortic Balloon Pumping, Kidney Failure, Chronic, Length of Stay, Male, Middle Aged, Postoperative Complications, Prospective Studies, Retrospective Studies, Risk Factors, Stroke Volume, Prevalence, Odds Ratio, Databases, Factual, Treatment Outcome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review