Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 300

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Midterm outcomes after aortic valve neocuspidization with glutaraldehyde-treated autologous pericardium

Open access
Ozaki, Shigeyuki, Kawase, Isamu, Yamashita, Hiromasa, Uchida, Shin, Takatoh, Mikio, Kiyohara, Nagaki · 2018 · The Journal of Thoracic and Cardiovascular Surgery

Abstract

Objective: We had previously reported the short‐term results of the aortic valve neocuspidization (AVNeo) procedure. We have now evaluated the midterm results with the longest follow‐up of 118 months. Methods: From April 2007 through December 2015, 850 patients were treated with AVNeo using autologous pericardium. Medical records of these patients were retrospectively reviewed. The procedure was on the basis of independent tricuspid replacement using autologous pericardium. The distances between the commissures were measured with an original sizing device, the pericardial cusp was trimmed using an original template, and then sutured to the annulus. Results: There were 534 patients with aortic stenosis, 254 with aortic regurgitation, 61 with aortic stenoregurgitation, 19 with infective endocarditis, and 5 with a previous aortic valve procedure. Besides 596 patients with tricuspid aortic valve, 224 patients had bicuspid valve, 28 had unicuspid valve, and 2 had quadricuspid valve. There were 444 male and 406 female patients. The median age was 71 (range, 13–90) years old. Preoperative echocardiography revealed a peak pressure gradient average of 68.9 ± 36.3 mm Hg with aortic stenosis. Surgical annular diameter was 20.9 ± 3.3 mm. There was no conversion to a prosthetic valve replacement. There were 16 in‐hospital mortalities. Postoperative echocardiography revealed a peak pressure gradient average of 19.5 ± 10.3 mm Hg 1 week after surgery and 15.2 ± 6.3 mm Hg 8 years after surgery. Fifteen patients needed reoperation (13 infective endocarditis, 1 break of thread, and 1 tear of cusp case). The mean follow‐up period was 53.7 ± 28.2 months. Actuarial freedom from death, cumulative incidence of reoperation, and that of recurrent moderate aortic regurgitation or greater was 85.9%, 4.2%, and 7.3%, respectively, with the longest follow‐up of 118 months. Conclusions: The midterm outcomes of AVNeo using autologous pericardium were satisfactory in 850 patients with various aortic valve diseases. However, further randomized, multicenter prospective studies are needed to confirm the results of the current study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jtcvs.2018.01.087

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 300

Metadata

Authors
Ozaki, S., Kawase, I., Yamashita, H., Uchida, S., Takatoh, M., & Kiyohara, N.
Venue
The Journal of Thoracic and Cardiovascular Surgery
Publisher
Elsevier BV
Published
2018-06
Volume
155
Issue
6
Pages
2379-2387
ISSN
0022-5223 (ISSN-L)
OpenAlex
W2785585747
Cited by
300
References
7
FWCI
22.19
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Midterm outcomes after aortic valve neocuspidization with glutaraldehyde-treated autologous pericardium. https://app.cochat.ai/papers/10.1016/j.jtcvs.2018.01.087
The paper
Ozaki, S., Kawase, I., Yamashita, H., Uchida, S., Takatoh, M., & Kiyohara, N. (2018). Midterm outcomes after aortic valve neocuspidization with glutaraldehyde-treated autologous pericardium. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2018.01.087

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.