The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Neurologic complications after the frozen elephant trunk procedure: A meta-analysis of more than 3000 patients
Open accessAbstract
OBJECTIVE: The frozen elephant trunk technique's safety regarding spinal cord ischemia has been questioned. We used a meta-analysis to determine the rates of adverse neurologic events and mortality. METHODS: We searched PubMed/Medline, Embase, Scopus, and Cochrane databases (inception to April 2018) to identify studies of neurologic events after the frozen elephant trunk procedure. Separate meta-analyses were conducted with random-effects models to assess frozen elephant trunk associations with spinal cord ischemia, stroke, operative mortality, and all adverse events combined. Subgroup analyses compared outcomes in patients with acute versus nonacute type A dissection and aneurysm and with different extents of coverage. RESULTS: Thirty-five studies (total N = 3154) met inclusion criteria. The pooled rates of the outcomes of interest were 4.7% (95% confidence interval, 3.5-6.2) for spinal cord ischemia, 7.6% (95% confidence interval, 5.0-11.5) for stroke, and 8.8% (95% confidence interval, 7.0-10.9) for operative mortality. The spinal cord ischemia event rate was higher with stent length 15 cm or greater or coverage to T8 or beyond than with stent length of 10 cm (11.6% vs 2.5%, P < .001). Adverse event rates in patients with acute type A aortic dissection versus nonacute dissection or aneurysm were as follows: mortality 9.2% versus 7.6% (P = .46), stroke 9.3% versus 6.6% (P = .51), and overall adverse events 22.0% versus 16.5% (P = .41). CONCLUSIONS: As the frozen elephant trunk procedure becomes more popular, accurate data regarding outcomes are vital. We associated the frozen elephant trunk technique with (nonsignificantly) more adverse events overall in acute type A dissection cases. Stent length of 10 cm was associated with significantly less risk of spinal cord ischemia. Using a stent 15 cm or greater or coverage extending to T8 or farther should be avoided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223
Basics of meta‐analysis: I 2 is not an absolute measure of heterogeneity
Borenstein, M., Higgins, J. P. T., Hedges, L. V., & Rothstein, H. R. (2017) · Research Synthesis Methods · doi:10.1002/jrsm.1230 · Cited by 1,848
Cited by
Isselbacher, E. M., Preventza, O., Hamilton Black, J., Augoustides, J. G., Beck, A. W., Bolen, M. A., Braverman, A. C., Bray, B. E., Brown-Zimmerman, M. M., Chen, E. P., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001106 · Cited by 2,082
2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease
Isselbacher, E. M., Preventza, O., Hamilton Black III, J., Augoustides, J. G., Beck, A. W., Bolen, M. A., Braverman, A. C., Bray, B. E., Brown-Zimmerman, M. M., Chen, E. P., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.08.004 · Cited by 619
Self-citationMalaisrie, S. C., Szeto, W. Y., Halas, M., Girardi, L. N., Coselli, J. S., Sundt, T. M., Chen, E. P., Fischbein, M. P., Gleason, T. G., Okita, Y., et al. (2021) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2021.04.053 · Cited by 348
Self-citation
Metadata
- Authors
- Preventza, O., Liao, J. L., Olive, J. K., Simpson, K., Critsinelis, A. C., Price, M. D., Galati, M., Cornwell, L. D., Orozco-Sevilla, V., Omer, S., Jimenez, E., LeMaire, S. A., & Coselli, J. S.
- Venue
- The Journal of Thoracic and Cardiovascular Surgery
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 160
- Issue
- 1
- Pages
- 20-33.e4
- ISSN
- 0022-5223 (ISSN-L)
- OpenAlex
- W2980732464
- Cited by
- 233
- References
- 2
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.