The DOI matches its Crossref record.
Intraoperative Near Infrared Fluorescence Guided Identification of the Ureters Using Low Dose Methylene Blue: A First in Human Experience
Open accessAbstract
PURPOSE: Near infrared fluorescence imaging is a promising technique that offers real-time visual information during surgery. In this study we report the first clinical results to our knowledge of ureteral imaging using near infrared fluorescence after a simple peripheral infusion of methylene blue. Furthermore, we assessed the optimal timing and dose of methylene blue. MATERIALS AND METHODS: A total of 12 patients who underwent lower abdominal surgery were included in this prospective feasibility study. Near infrared fluorescence imaging was performed using the Mini-FLARE™ imaging system. To determine optimal timing and dose, methylene blue was injected intravenously at doses of 0.25, 0.5 or 1 mg/kg after exposure of the ureters. Imaging was performed for up to 60 minutes after injection. RESULTS: In all patients both ureters could be clearly visualized within 10 minutes after infusion of methylene blue. The signal lasted at least up to 60 minutes after injection. The mean signal-to-background ratio of the ureter was 2.27 ± 1.22 (4), 2.61 ± 1.88 (4) and 3.58 ± 3.36 (4) for the 0.25, 0.5 and 1 mg/kg groups, respectively. A mixed model analysis was used to compare signal-to-background ratios among dose groups and times, and to assess the relationship between dose and time. A significant difference among time points (p <0.001) was found. However, no difference was observed among dose groups (p = 0.811). CONCLUSIONS: This study demonstrates the first successful use of near infrared fluorescence using low dose methylene blue for the identification of the ureters during lower abdominal surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
Self-citationLi, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801226 · Cited by 658
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
NIR-II nanoprobes in-vivo assembly to improve image-guided surgery for metastatic ovarian cancer
Wang, P., Fan, Y., Lu, L., Liu, L., Fan, L., Zhao, M., Xie, Y., Xu, C., & Zhang, F. (2018) · Nature Communications · doi:10.1038/s41467-018-05113-8 · Cited by 451
Metadata
- Authors
- Verbeek, F. P. R., van der Vorst, J. R., Schaafsma, B. E., Swijnenburg, R.-J., Gaarenstroom, K. N., Elzevier, H. W., van de Velde, C. J. H., Frangioni, J. V., & Vahrmeijer, A. L.
- Venue
- Journal of Urology
- Published
- 2013-08
- Volume
- 190
- Issue
- 2
- Pages
- 574-579
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2144603071
- Cited by
- 176
- References
- 0
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative Near Infrared Fluorescence Guided Identification of the Ureters Using Low Dose Methylene Blue: A First in Human Experience. https://app.cochat.ai/papers/10.1016/j.juro.2013.02.3187
- The paper
- Verbeek, F. P. R., van der Vorst, J. R., Schaafsma, B. E., Swijnenburg, R.-J., Gaarenstroom, K. N., Elzevier, H. W., van de Velde, C. J. H., Frangioni, J. V., & Vahrmeijer, A. L. (2013). Intraoperative Near Infrared Fluorescence Guided Identification of the Ureters Using Low Dose Methylene Blue: A First in Human Experience. Journal of Urology. https://doi.org/10.1016/j.juro.2013.02.3187
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.