The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Magnetic Resonance Imaging Underestimation of Prostate Cancer Geometry: Use of Patient Specific Molds to Correlate Images with Whole Mount Pathology
Open accessAbstract
PURPOSE: We evaluated the accuracy of magnetic resonance imaging in determining the size and shape of localized prostate cancer. MATERIALS AND METHODS: The subjects were 114 men who underwent multiparametric magnetic resonance imaging before radical prostatectomy with patient specific mold processing of the specimen from 2013 to 2015. T2-weighted images were used to contour the prostate capsule and cancer suspicious regions of interest. The contours were used to design and print 3-dimensional custom molds, which permitted alignment of excised prostates with magnetic resonance imaging scans. Tumors were reconstructed in 3 dimensions from digitized whole mount sections. Tumors were then matched with regions of interest and the relative geometries were compared. RESULTS: Of the 222 tumors evident on whole mount sections 118 had been identified on magnetic resonance imaging. For the 118 regions of interest mean volume was 0.8 cc and the longest 3-dimensional diameter was 17 mm. However, for matched pathological tumors, of which most were Gleason score 3 + 4 or greater, mean volume was 2.5 cc and the longest 3-dimensional diameter was 28 mm. The median tumor had a 13.5 mm maximal extent beyond the magnetic resonance imaging contour and 80% of cancer volume from matched tumors was outside region of interest boundaries. Size estimation was most accurate in the axial plane and least accurate along the base-apex axis. CONCLUSIONS: Magnetic resonance imaging consistently underestimates the size and extent of prostate tumors. Prostate cancer foci had an average diameter 11 mm longer and a volume 3 times greater than T2-weighted magnetic resonance imaging segmentations. These results may have important implications for the assessment and treatment of prostate cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PI-RADS Prostate Imaging – Reporting and Data System: 2015, Version 2
Weinreb, J. C., Barentsz, J. O., Choyke, P. L., Cornud, F., Haider, M. A., Macura, K. J., Margolis, D., Schnall, M. D., Shtern, F., Tempany, C. M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.08.052 · Cited by 2,951
Self-citationStamey, T. A., Freiha, F. S., McNeal, J. E., Redwine, E. A., Whittemore, A. S., & Schmid, H.-P. (1993) · Cancer · doi:10.1002/1097-0142(19930201)71:3+<933::aid-cncr2820711408>3.0.co;2-l · Cited by 799
Türkbey, B., Mani, H., Shah, V. P., Rastinehad, A. R., Bernardo, M., Pohida, T. J., Pang, Y., Daar, D., Benjamin, C. J., McKinney, Y. L., et al. (2011) · The Journal of Urology · doi:10.1016/j.juro.2011.07.013 · Cited by 497
Hegde, J. V., Mulkern, R. V., Panych, L. P., Fennessy, F. M., Fedorov, A., Maier, S. E., & Tempany, C. M. C. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23860 · Cited by 241
Mazaheri, Y., Hricak, H., Fine, S. W., Akin, O., Shukla-Dave, A., Ishill, N. M., Moskowitz, C. S., Grater, J. E., Reuter, V. E., Zakian, K. L., et al. (2009) · Radiology · doi:10.1148/radiol.2523081423 · Cited by 205
Le Nobin, J., Rosenkrantz, A. B., Villers, A., Orczyk, C., Deng, F.-M., Melamed, J., Mikheev, A., Rusinek, H., & Taneja, S. S. (2015) · Journal of Urology · doi:10.1016/j.juro.2015.02.080 · Cited by 189
Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI
Madabhushi, A., Feldman, M. D., Metaxas, D. N., Tomaszeweski, J., & Chute, D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.859208 · Cited by 184
Chappelow, J., Bloch, B., Rofsky, N. M., Genega, E. M., Lenkinski, R. E., DeWolf, W. C., & Madabhushi, A. (2011) · Medical Physics · doi:10.1118/1.3560879 · Cited by 115
Validation of functional imaging with pathology for tumor delineation in the prostate
Groenendaal, G., Moman, M. R., Korporaal, J. G., van Diest, P. J., van Vulpen, M., Philippens, M. E. P., & van der Heide, U. A. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2009.12.034 · Cited by 106
Registration Methodology for Histological Sections and In Vivo Imaging of Human Prostate
Park, H., Piert, M., Khan, A. S., Shah, R. B., Hussain, H. K., Siddiqui, J., Chenevert, T. L., & Meyer, C. R. (2008) · Academic Radiology · doi:10.1016/j.acra.2008.01.022 · Cited by 98
Cited by
A survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207
Metadata
- Authors
- Priester, A., Natarajan, S., Khoshnoodi, P., Margolis, D. J., Raman, S. S., Reiter, R. E., Huang, J., Grundfest, W., & Marks, L. S.
- Venue
- Journal of Urology
- Published
- 2017-02
- Volume
- 197
- Issue
- 2
- Pages
- 320-326
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2546110733
- Cited by
- 254
- References
- 14
- FWCI
- 20.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Imaging Underestimation of Prostate Cancer Geometry: Use of Patient Specific Molds to Correlate Images with Whole Mount Pathology. https://app.cochat.ai/papers/10.1016/j.juro.2016.07.084
- The paper
- Priester, A., Natarajan, S., Khoshnoodi, P., Margolis, D. J., Raman, S. S., Reiter, R. E., Huang, J., Grundfest, W., & Marks, L. S. (2017). Magnetic Resonance Imaging Underestimation of Prostate Cancer Geometry: Use of Patient Specific Molds to Correlate Images with Whole Mount Pathology. Journal of Urology. https://doi.org/10.1016/j.juro.2016.07.084
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.