Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI

Madabhushi, A., Feldman, M.D., Metaxas, D.N., Tomaszeweski, J., Chute, D. · 2005 · IEEE Transactions on Medical Imaging

Abstract

Prostatic adenocarcinoma is the most commonly occurring cancer among men in the United States, second only to skin cancer. Currently, the only definitive method to ascertain the presence of prostatic cancer is by trans-rectal ultrasound (TRUS) directed biopsy. Owing to the poor image quality of ultrasound, the accuracy of TRUS is only 20%-25%. High-resolution magnetic resonance imaging (MRI) has been shown to have a higher accuracy of prostate cancer detection compared to ultrasound. Consequently, several researchers have been exploring the use of high resolution MRI in performing prostate biopsies. Visual detection of prostate cancer, however, continues to be difficult owing to its apparent lack of shape, and the fact that several malignant and benign structures have overlapping intensity and texture characteristics. In this paper, we present a fully automated computer-aided detection (CAD) system for detecting prostatic adenocarcinoma from 4 Tesla ex vivo magnetic resonance (MR) imagery of the prostate. After the acquired MR images have been corrected for background inhomogeneity and nonstandardness, novel three-dimensional (3-D) texture features are extracted from the 3-D MRI scene. A Bayesian classifier then assigns each image voxel a "likelihood" of malignancy for each feature independently. The "likelihood" images generated in this fashion are then combined using an optimally weighted feature combination scheme. Quantitative evaluation was performed by comparing the CAD results with the manually ascertained ground truth for the tumor on the MRI. The tumor labels on the MR slices were determined manually by an expert by visually registering the MR slices with the corresponding regions on the histology slices. We evaluated our CAD system on a total of 33 two-dimensional (2-D) MR slices from five different 3-D MR prostate studies. Five slices from two different glands were used for training. Our feature combination scheme was found to outperform the individual texture features, and also other popularly used feature combination methods, including AdaBoost, ensemble averaging, and majority voting. Further, in several instances our CAD system performed better than the experts in terms of accuracy, the expert segmentations being determined solely from visual inspection of the MRI data. In addition, the intrasystem variability (changes in CAD accuracy with changes in values of system parameters) was significantly lower than the corresponding intraobserver and interobserver variability. CAD performance was found to be very similar for different training sets. Future work will focus on extending the methodology to guide high-resolution MRI-assisted in vivo prostate biopsies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2005.859208

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 184

Metadata

Authors
Madabhushi, A., Feldman, M. D., Metaxas, D. N., Tomaszeweski, J., & Chute, D.
Venue
IEEE Transactions on Medical Imaging
Published
2005-12
Volume
24
Issue
12
Pages
1611-1625
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2125878029
Cited by
184
References
3
FWCI
9.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI. https://app.cochat.ai/papers/10.1109/tmi.2005.859208
The paper
Madabhushi, A., Feldman, M. D., Metaxas, D. N., Tomaszeweski, J., & Chute, D. (2005). Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.859208

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.