CoChat

Validation of the IMS CORE Diabetes Model

Open access
McEwan, Phil, Foos, Volker, Palmer, James L., Lamotte, Mark, Lloyd, Adam, Grant, David · 2014 · Value in Health
Cited by 235

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The IMS CORE Diabetes Model (CDM) is a widely published and validated simulation model applied in both type 1 diabetes mellitus (T1DM) and type 2 diabetes mellitus (T2DM) analyses. Validation to external studies is an important part of demonstrating model credibility. OBJECTIVE: Because the CDM is widely used to estimate long-term clinical outcomes in diabetes patients, the objective of this analysis was to validate the CDM to contemporary outcomes studies, including those with long-term follow-up periods. METHODS: A total of 112 validation simulations were performed, stratified by study follow-up duration. For long-term results (≥15-year follow-up), simulation cohorts representing baseline Diabetes Control and Complications Trial (DCCT) and United Kingdom Prospective Diabetes Study (UKPDS) cohorts were generated and intensive and conventional treatment arms were defined in the CDM. Predicted versus observed macrovascular and microvascular complications and all-cause mortality were assessed using the coefficient of determination (R(2)) goodness-of-fit measure. RESULTS: Across all validation studies, the CDM simulations produced an R(2) statistic of 0.90. For validation studies with a follow-up duration of less than 15 years, R(2) values of 0.90 and 0.88 were achieved for T1DM and T2DM respectively. In T1DM, validating against 30-year outcomes data (DCCT) resulted in an R(2) of 0.72. In T2DM, validating against 20-year outcomes data (UKPDS) resulted in an R(2) of 0.92. CONCLUSIONS: This analysis supports the CDM as a credible tool for predicting the absolute number of clinical events in DCCT- and UKPDS-like populations. With increasing incidence of diabetes worldwide, the CDM is particularly important for health care decision makers, for whom the robust evaluation of health care policies is essential.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jval.2014.07.007

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 235

Metadata

Authors
McEwan, P., Foos, V., Palmer, J. L., Lamotte, M., Lloyd, A., & Grant, D.
Venue
Value in Health
Publisher
Elsevier BV
Published
2014-09
Volume
17
Issue
6
Pages
714-724
ISSN
1098-3015 (ISSN-L)
OpenAlex
W2039713231
Cited by
235
References
16
FWCI
12.45
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of the IMS CORE Diabetes Model. https://app.cochat.ai/papers/10.1016/j.jval.2014.07.007
The paper
McEwan, P., Foos, V., Palmer, J. L., Lamotte, M., Lloyd, A., & Grant, D. (2014). Validation of the IMS CORE Diabetes Model. Value in Health. https://doi.org/10.1016/j.jval.2014.07.007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.