How precise can bony landmarks be determined on a CT scan of the knee?
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to describe the intra- and inter-observer variability of the registration of bony landmarks and alignment axes on a Computed Axial Tomography (CT) scan. Six cadaver specimens were scanned. Three-dimensional surface models of the knee were created. Three observers marked anatomic surface landmarks and alignment landmarks. The intra- and inter-observer variability of the point and axis registration was performed. Mean intra-observer precision ranks around 1 mm for all landmarks. The intra-class correlation coefficient (ICC) for inter-observer variability ranked higher than 0.98 for all landmarks. The highest recorded intra- and inter-observer variability was 1.3 mm and 3.5 mm respectively and was observed for the lateral femoral epicondyle. The lowest variability in the determination of axes was found for the femoral mechanical axis (intra-observer 0.12 degrees and inter-observer 0.19 degrees) and for the tibial mechanical axis (respectively 0.15 degrees and 0.28 degrees). In the horizontal plane the lowest variability was observed for the posterior condylar line of the femur (intra-observer 0.17 degrees and inter-observer 0.78 degrees) and for the transverse axis (respectively 1.89 degrees and 2.03) on the tibia. This study demonstrates low intra- and inter-observer variability in the CT registration of landmarks that define the coordinate system of the femur and the tibia. In the femur, the horizontal plane projections of the posterior condylar line and the surgical and anatomical transepicondylar axis can be determined precisely on a CT scan, using the described methodology. In the tibia, the best result is obtained for the tibial transverse axis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coronal alignment after total knee replacement
Jeffery, R., Morris, R., & Denham, R. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b5.1894655 · Cited by 1,100 · cited 1×
“Failure to obtain correct alignment in total knee arthroplasty leads to inferior results and early revisions [12–21,39–43].”
Statistics Notes: Measurement error
Bland, J. M., & Altman, D. G. (1996) · BMJ · doi:10.1136/bmj.313.7059.744 · Cited by 1,070
Postoperative Alignment of Total Knee Replacement Its Effect on Survival
RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00021 · Cited by 1,008 · cited 1×
“Failure to obtain correct alignment in total knee arthroplasty leads to inferior results and early revisions [12–21,39–43].”
The Anatomy of the Medial Part of the Knee
LaPrade, R. F., Ly, T. V., Wentorf, F. A., Engebretsen, A. H., Johansen, S., & Engebretsen, L. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200709000-00016 · Cited by 919
ANOUCHI, Y. S., WHITESIDE, L. A., KAISER, A. D., & MILLIANO, M. T. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199302000-00027 · Cited by 382 · cited 1×
“Failure to obtain correct alignment in total knee arthroplasty leads to inferior results and early revisions [12–21,39–43].”
BackgroundEffect of Rotational Alignment On Patellar Tracking in Total Knee Arthroplasty
Akagi, M., Matsusue, Y., Mata, T., Asada, Y., Horiguchi, M., Iida, H., & Nakamura, T. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199909000-00019 · Cited by 358 · cited 1×
“Failure to obtain correct alignment in total knee arthroplasty leads to inferior results and early revisions [12–21,39–43].”
BackgroundOptimizing Femoral Component Rotation in Total Knee Arthroplasty
Miller, M. C., Berger, R. A., Petrella, A. J., Karmas, A., & Rubash, H. E. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200111000-00005 · Cited by 310 · cited 2×
“position of different axes [15–17,23–26].”
BackgroundThe effect of valgus/varus malalignment on load distribution in total knee replacements
Werner, F. W., Ayers, D. C., Maletsky, L. P., & Rullkoetter, P. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.024 · Cited by 289 · cited 1×
“Failure to obtain correct alignment in total knee arthroplasty leads to inferior results and early revisions [12–21,39–43].”
BackgroundDeFrate, L. E., Papannagari, R., Gill, T. J., Moses, J. M., Pathare, N. P., & Li, G. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506287299 · Cited by 272
Anatomy of the epicondyles of the distal femur
Griffin, F. M., Math, K., Scuderi, G. R., Insall, J. N., & Poilvache, P. L. (2000) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(00)90739-3 · Cited by 253 · cited 1×
“In the pre-operative planning, the surgical transepicondylar axis is often considered an optimal reference for horizontal plane alignment of the femoral component [23,40].”
The Effect of Femoral Component Position on Patellar Tracking After Total Knee Arthroplasty
RHOADS, D. D., NOBLE, P. C., REUBEN, J. D., MAHONEY, O. M., & TULLOS, H. S. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199011000-00009 · Cited by 238 · cited 1×
“Failure to obtain correct alignment in total knee arthroplasty leads to inferior results and early revisions [12–21,39–43].”
BackgroundYoshino, N., Takai, S., Ohtsuki, Y., & Hirasawa, Y. (2001) · The Journal of Arthroplasty · doi:10.1054/arth.2001.23621 · Cited by 225 · cited 2×
“position of different axes [15–17,23–26].”
BackgroundDynamic activity dependence of in vivo normal knee kinematics
Moro‐oka, T., Hamai, S., Miura, H., Shimoto, T., Higaki, H., Fregly, B. J., Iwamoto, Y., & Banks, S. A. (2008) · Journal of Orthopaedic Research · doi:10.1002/jor.20488 · Cited by 188 · cited 4×
“It is unclear whether the same accuracy could be achieved in using an MRI scan.”
InfluentialFemoral Component Rotation During Total Knee Arthroplasty
Olcott, C. W., & Scott, R. D. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199910000-00005 · Cited by 187
Robot-assisted Total Knee Arthroplasty
Bellemans, J., Vandenneucker, H., & Vanlauwe, J. (2007) · Clinical Orthopaedics & Related Research · doi:10.1097/blo.0b013e318126c0c0 · Cited by 178 · cited 3×
“This is fundamental, as it is the basis for all applications of CT data in the clinical setting [2–8].”
BackgroundMethodSelf-citationThe Ranawat Award. Femoral component rotation during total knee arthroplasty.
Olcott, C. W., & Scott, R. D. (1999) · PubMed · Cited by 150
The High Variability of Tibial Rotational Alignment in Total Knee Arthroplasty
Siston, R. A., Goodman, S. B., Patel, J. J., Delp, S. L., & Giori, N. J. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000229335.36900.a0 · Cited by 125 · cited 1×
“Even in more idealized circumstances, using cadavers with or without soft tissues there is significant variability among observers [36,37,45–47].”
Influence of prosthetic joint line position on knee kinematics and patellar position
Yoshii, I., Whiteside, L. A., White, S., & Milliano, M. T. (1991) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(11)80013-6 · Cited by 117 · cited 2×
“as rotational malalignment of the femoral component has been determined as a main cause of poor clinical outcome after TKA [12– 21].”
BackgroundComputed Tomography-Based Navigation for Hip, Knee, and Spine Surgery
Amiot, L.-P., & Poulin, F. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000126866.29933.42 · Cited by 103 · cited 3×
“This is fundamental, as it is the basis for all applications of CT data in the clinical setting [2–8].”
BackgroundMethodVariability of Landmark Identification in Total Knee Arthroplasty
Robinson, M., Eckhoff, D. G., Reinig, K. D., Bagur, M., & Bach, J. M. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000197081.72341.4b · Cited by 84 · cited 1×
“The outcome of a given procedure in terms of alignment or position is often described as a comparison to a reference value, obtained from a CT scan [8,36,37].”
Reliability of the Transepicondylar Axis as an Anatomical Landmark in Total Knee Arthroplasty
Stoeckl, B., Nogler, M., Krismer, M., Beimel, C., de la Barrera, J.-L. M., & Kessler, O. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.10.020 · Cited by 77 · cited 1×
“[47] reported the inter-observer variability as a 95th percentile of the distances between the clinical registrations, compared to the CT registrations.”
der Zwaag, H. M. J. V. D. L.-V., Valstar, E. R., van der Molen, A. J., & Nelissen, R. G. H. H. (2008) · Computer Aided Surgery · doi:10.3109/10929080802240134 · Cited by 39 · cited 2×
“Several authors have emphasized the important inter- and intraobserver variability in the surgical location of the femoral epicondyles [8,10,24,25,29,44].”
Oberst, M., Bertsch, C., Lahm, A., Wuerstlin, S., & Holz, U. (2006) · Computer Aided Surgery · doi:10.1080/10929080600632680 · Cited by 23
Cited by
Multi-Scale Deep Reinforcement Learning for Real-Time 3D-Landmark Detection in CT Scans
Ghesu, F.-C., Georgescu, B., Zheng, Y., Grbic, S., Maier, A., Hornegger, J., & Comaniciu, D. (2019) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2017.2782687 · Cited by 310
Metadata
- Authors
- Victor, J., Van Doninck, D., Labey, L., Innocenti, B., Parizel, P. M., & Bellemans, J.
- Venue
- The Knee
- Publisher
- Elsevier BV
- Published
- 2009-10
- Volume
- 16
- Issue
- 5
- Pages
- 358-365
- ISSN
- 0968-0160 (ISSN-L)
- OpenAlex
- W2019591724
- Cited by
- 228
- References
- 23
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.