Do long leg supine CT scanograms correlate with weight-bearing full-length radiographs to measure lower limb coronal alignment?
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
INTRODUCTION The gold standard for measuring knee alignment is the lower limb mechanical axis (MA) using weight-bearing lower limb full-length x-ray (FLX). However, CT scanograms (CTS) are becoming increasingly popular in view of lower radiation exposure, speed of data acquisition and supine positioning. We compared the correlation and degree of agreement of knee joint coronal alignment using these two imaging modalities. METHOD From our series of complex primary and revision knee arthroplasty patients, we selected those with both FLX and CTS recorded onto digital PACS. The coronal alignments were assessed in 24 knees and the valgus/varus angles relative to the MA were measured. Results were analysed statistically using the paired samples t-test, Pearson's correlation coefficient, intra-class correlation coefficient, Cohen's kappa and Passing and Bablok regression to assess potential equality of methods. RESULTS The mean MA was 180.5° (165°-200°) for the CTS and 181° (164°-202°) for the FLX. The CTS MA angle data between the assessors were highly correlated (r=0.971, p <0.001) as were FLX MA angle measurements (r=0.988, p <0.001). 41.7% of the CTS and 37.5% of the FLX were in varus alignment, while 50% of the CTS and 43.8% of the FLX were in valgus alignment. Malalignment >5° was revealed by 18.8% of the CTS and 35.4% of the FLX. CONCLUSION Overall, good agreement was observed in MA angle data between the two imaging modalities, but reproducibility may be problematic. In the malaligned limb, weight-bearing FLX still remains a vital imaging modality. CTS should be used with caution in view of the under-detection of malalignment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Passing, H., & Bablok, W. (1983) · cclm · doi:10.1515/cclm.1983.21.11.709 · Cited by 1,513
Cited by
Tarassoli, P., Corban, L. E., Wood, J. A., Sergis, A., Chen, D. B., & MacDessi, S. J. (2023) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-023-07505-w · Cited by 51
Tarassoli, P., Wood, J. A., Chen, D. B., Griffiths‐Jones, W., Bellemans, J., & MacDessi, S. J. (2022) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-022-07038-8 · Cited by 46
Gieroba, T. J., Marasco, S., Babazadeh, S., Di Bella, C., & van Bavel, D. (2023) · Arthroplasty · doi:10.1186/s42836-023-00193-4 · Cited by 28
Which Knee Phenotypes Exhibit the Strongest Correlation With Cartilage Degeneration?
Khury, F., Oltmanns, M., Unseld, T., Fuchs, M., Reichel, H., & Faschingbauer, M. (2024) · Clinical Orthopaedics & Related Research · doi:10.1097/corr.0000000000002831 · Cited by 13
“Sixth, despite possible criticism [23] for having less accuracy than other imaging modalities such as CT or MRI, studies [3, 16] reported acceptable results between CT scans and full-limb radio-graphs.”
Result
Metadata
- Authors
- Gbejuade, H. O., White, P., Hassaballa, M., Porteous, A. J., Robinson, J. R., & Murray, J. R.
- Venue
- The Knee
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 21
- Issue
- 2
- Pages
- 549-552
- ISSN
- 0968-0160 (ISSN-L)
- OpenAlex
- W2082385491
- Cited by
- 61
- References
- 1
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Do long leg supine CT scanograms correlate with weight-bearing full-length radiographs to measure lower limb coronal alignment? https://app.cochat.ai/papers/10.1016/j.knee.2013.05.009
- The paper
- Gbejuade, H. O., White, P., Hassaballa, M., Porteous, A. J., Robinson, J. R., & Murray, J. R. (2014). Do long leg supine CT scanograms correlate with weight-bearing full-length radiographs to measure lower limb coronal alignment? The Knee. https://doi.org/10.1016/j.knee.2013.05.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.