Effect of porosity variation strategy on the performance of functionally graded Ti-6Al-4V scaffolds for bone tissue engineering
Open accessAbstract
Abstract Functionally graded scaffold (FGS) is designed to mimic the morphology, mechanical and biological properties of natural bone closely. Porosity variation strategy between different regions in FGS plays a crucial role in influencing its mechanical and biological performance. A combination of modeling tool and scripting language can effectively enhance the ability to optimize FGS design. This study was aimed at determining the effect of porosity variation strategy on the mechanical performance and permeability of the as-built and as-heat-treated FGSs. Ti-6Al-4V FGSs with sizes of 10 × 10 × 15 mm and diamond lattice structures were designed and fabricated by means of selective laser melting. A wide range of porosities in the FGSs (38–75%) were achieved by applying six different porosity variation strategies. The elastic modulus (3.7–5.7 GPa) and yield strength (27.1–84.7 MPa) of the as-built FGSs were found to vary between the corresponding mechanical properties of cancellous bone and cortical bone. Heat treatment reduced the strengths by 13–56%. Porosity variation strategy strongly affected the deformation behavior and failure mechanisms of the FGSs. The sigmoid function-controlled FGSs showed gradual failure behavior and sample Sigk0.5b8 showed superior overall performance. The results demonstrated that porosity variation strategy is a feasible means for tailor design of FGS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Cited by
Li, Y., Feng, Z., Hao, L., Huang, L., Xin, C., Wang, Y., Bilotti, E., Essa, K., Zhang, H., Li, Z., et al. (2020) · Advanced Materials Technologies · doi:10.1002/admt.201900981 · Cited by 614
Zhou, H., Zhao, M., Ma, Z., Zhang, D. Z., & Fu, G. (2020) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2020.105480 · Cited by 265
Metadata
- Authors
- Zhang, X.-Y., Fang, G., Xing, L.-L., Liu, W., & Zhou, J.
- Venue
- Materials & Design
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 157
- Pages
- 523-538
- ISSN
- 0264-1275 (ISSN-L)
- OpenAlex
- W2885199833
- Cited by
- 162
- References
- 2
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of porosity variation strategy on the performance of functionally graded Ti-6Al-4V scaffolds for bone tissue engineering. https://app.cochat.ai/papers/10.1016/j.matdes.2018.07.064
- The paper
- Zhang, X.-Y., Fang, G., Xing, L.-L., Liu, W., & Zhou, J. (2018). Effect of porosity variation strategy on the performance of functionally graded Ti-6Al-4V scaffolds for bone tissue engineering. Materials & Design. https://doi.org/10.1016/j.matdes.2018.07.064
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.