A review of techniques for the application of bioactive coatings on metal-based implants to achieve controlled release of active ingredients
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Metallic implants have the disadvantage of being insufficiently biologically active despite their good mechanical properties and general affordability. Therefore, their bone growth at the implant site in an osteoinductive and osteoconductive manner could be improved by using bioactive coatings with incorporated active ingredients (antibiotics, anti-inflammatory drugs, growth factors, osteoclast inhibitors, anticoagulants, etc.) that are released locally at the implant site in a controlled manner. In addition, the long-term exposure of metallic implant materials to a corrosive environment (human body fluids) can lead to toxic corrosion-induced ion release. To ensure the biological, non-corrosive, and appropriate mechanical properties of the implant-coating system, the choice of the coating method is crucial. This review describes recent developments in the application of bioactive coatings on metal implant materials, such as 3D printing, electrospinning, electrophoretic deposition, dip coating, drop casting, sol–gel deposition, biomimetic deposition, plasma spraying, layer-by-layer deposition, physical vapour deposition, and the formation of titanium oxide nanotubes by anodization. In addition, this work addresses promising ways to incorporate active ingredients into coatings through various entrapment methods of nano- and micro-encapsulation to achieve the desired controlled release.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier
Makadia, H. K., & Siegel, S. J. (2011) · Polymers · doi:10.3390/polym3031377 · Cited by 4,816
Kamaly, N., Yameen, B., Wu, J., & Farokhzad, O. C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00346 · Cited by 3,070
Fernandes, H. R., Gaddam, A., Rebelo, A., Brazete, D., Stan, G. E., & Ferreira, J. M. F. (2018) · Materials · doi:10.3390/ma11122530 · Cited by 397
Tao, B., Zhao, W., Lin, C., Yuan, Z., He, Y., Lu, L., Chen, M., Ding, Y., Yang, Y., Xia, Z., et al. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.124621 · Cited by 206
Cited by
Antibacterial coatings on orthopedic implants
Chen, X., Zhou, J., Qian, Y., & Zhao, L. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100586 · Cited by 246
Metadata
- Authors
- Kravanja, K. A., & Finšgar, M.
- Venue
- Materials & Design
- Publisher
- Elsevier BV
- Published
- 2022-05
- Volume
- 217
- Pages
- 110653
- ISSN
- 0264-1275 (ISSN-L)
- OpenAlex
- W4223968974
- Cited by
- 221
- References
- 4
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.