The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Heartbeat-Sensing Mechanoluminescent Device Based on a Quantitative Relationship between Pressure and Emissive Intensity
Open accessAbstract
Summary The pure organic mechanoluminescent luminogens (tPE-2-Th and tPE-3-Th), with their combination of aggregation-induced emission and the presence of a self-assembly unit, exhibit very bright mechanoluminescence (ML) emission even in daylight. Excitingly, the relationship between the pressure and ML intensity has been successfully established for the first time based on an ML device fabricated by tPE-2-Th. Furthermore, the flexible and wearable ML device demonstrates potential applications in communications, information storage, and health care. In particular, it provides a quick response to the human heartbeat, offering a new approach for the monitoring of force stimuli in daily life. Video Abstract Download : Download video (23MB)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Guo, J., Li, X., Nie, H., Luo, W., Gan, S., Hu, S., Hu, R., Qin, A., Zhao, Z., Su, S., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201606458 · Cited by 444
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Piezoelectric materials for flexible and wearable electronics: A review
Wu, Y., Ma, Y., Zheng, H., & Ramakrishna, S. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.110164 · Cited by 521
Mechanoluminescence Rebrightening the Prospects of Stress Sensing: A Review
Zhuang, Y., & Xie, R. (2021) · Advanced Materials · doi:10.1002/adma.202005925 · Cited by 507
Organic luminescent materials: The concentration on aggregates from aggregation‐induced emission
Yang, J., Fang, M., & Li, Z. (2020) · Aggregate · doi:10.1002/agt2.2 · Cited by 447
Self-citationZhang, J., He, B., Hu, Y., Alam, P., Zhang, H., Lam, J. W. Y., & Tang, B. Z. (2021) · Advanced Materials · doi:10.1002/adma.202008071 · Cited by 427
Metadata
- Authors
- Wang, C., Yu, Y., Yuan, Y., Ren, C., Liao, Q., Wang, J., Chai, Z., Li, Q., & Li, Z.
- Venue
- Matter
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 2
- Issue
- 1
- Pages
- 181-193
- ISSN
- 2590-2385 (ISSN-L)
- OpenAlex
- W2988163959
- Cited by
- 206
- References
- 2
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heartbeat-Sensing Mechanoluminescent Device Based on a Quantitative Relationship between Pressure and Emissive Intensity. https://app.cochat.ai/papers/10.1016/j.matt.2019.10.002
- The paper
- Wang, C., Yu, Y., Yuan, Y., Ren, C., Liao, Q., Wang, J., Chai, Z., Li, Q., & Li, Z. (2020). Heartbeat-Sensing Mechanoluminescent Device Based on a Quantitative Relationship between Pressure and Emissive Intensity. Matter. https://doi.org/10.1016/j.matt.2019.10.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.