CoChat

Artificial Intelligence ECG to Detect Left Ventricular Dysfunction in COVID-19

Open access
Attia, Zachi I., Kapa, Suraj, Noseworthy, Peter A., Lopez-Jimenez, Francisco, Friedman, Paul A. · 2020 · Mayo Clinic Proceedings
Cited by 39

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Coronavirus disease 2019 (COVID-19) can result in deterioration of cardiac function, which is associated with high mortality. A simple point-of-care diagnostic test to screen for ventricular dysfunction would be clinically useful to guide management. We sought to review the clinical experience with an artificial intelligence electrocardiogram (AI ECG) to screen for ventricular dysfunction in patients with documented COVID-19. We examined all patients in the Mayo Clinic system who underwent clinically indicated electrocardiography and echocardiography within 2 weeks following a positive COVID-19 test and had permitted use of their data for research were included. Of the 27 patients who met the inclusion criteria, one had a history of normal ventricular function who developed COVID-19 myocarditis with rapid clinical decline. The initial AI ECG in this patient indicated normal ventricular function. Repeat AI ECG showed a probability of ejection fraction (EF) less than or equal to 40% of 90.2%, corroborated with an echocardiographic EF of 35%. One other patient had a pre-existing EF less than or equal to 40%, accurately detected by the algorithm before and after COVID-19 diagnosis, and another was found to have a low EF by AI ECG and echocardiography with the COVID-19 diagnosis. The area under the curve for detection of EF less than or equal to 40% was 0.95. This case series suggests that the AI ECG, previously shown to detect ventricular dysfunction in a large general population, may be useful as a screening tool for the detection of cardiac dysfunction in patients with COVID-19.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.mayocp.2020.09.020

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 39

Metadata

Authors
Attia, Z. I., Kapa, S., Noseworthy, P. A., Lopez-Jimenez, F., & Friedman, P. A.
Venue
Mayo Clinic Proceedings
Publisher
Elsevier BV
Published
2020-11
Volume
95
Issue
11
Pages
2464-2466
ISSN
0025-6196 (ISSN-L)
OpenAlex
W3087663496
Cited by
39
References
5
FWCI
3.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Intelligence ECG to Detect Left Ventricular Dysfunction in COVID-19. https://app.cochat.ai/papers/10.1016/j.mayocp.2020.09.020
The paper
Attia, Z. I., Kapa, S., Noseworthy, P. A., Lopez-Jimenez, F., & Friedman, P. A. (2020). Artificial Intelligence ECG to Detect Left Ventricular Dysfunction in COVID-19. Mayo Clinic Proceedings. https://doi.org/10.1016/j.mayocp.2020.09.020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.